Laserfiche WebLink
Symbols Numbering System A General Safety Notes <br /> PLATE LOCATION AND ORIENTATION <br /> 3I" Center plate on joint unless x,y 6-4-8 dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property <br /> 4 offsets are indicated. I (Drawings not to scale) Damage or Personal Injury <br /> MMDimensions are in ft-in-sixteenths. <br /> ok Apply plates to both sides of truss 1 2 3 1. Additional stability bracing for truss system,e.g. <br /> and fully embed teeth. diagonal or X-bracing,is always required. See BCSI. <br /> TOP CHORDS <br /> 2. Truss bracing must be designed by an engineer.For <br /> 0'1116 4 wide truss spacing,individual lateral braces themselves <br /> 11L11111111tdi <br /> mayrequirebracingoralternativeTorIpbracing should be considered. <br /> ■_ 3. Nexed degnqldig hwn d ve d stack materialscethe on inadequately bracedsotrusses.anne <br /> p 4. Provideevrecopies of this trussoadesign <br /> nto the building r <br /> C7-8 C6.7 C5-6 <br /> For 4 x 2 orientation,locate � designer,erection supervisor,property owner and <br /> plates 0- ',d'from outside BOTTOM CHORDS all other interested parties. <br /> edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. <br /> 6. Place plates on each face of truss at each <br /> This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint <br /> - required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSIITPI 1. <br /> connector plates. THE LEFT. <br /> 7. Design assumes trusses will be suitably protected from <br /> CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSIITPI 1. <br /> *Plate location details available in MiTek 20/20 NUMBERS/LETTERS. <br /> software or upon request. 8. Unless otherwise noted,moisture content of lumber <br /> shall not exceed 19%at time of fabrication. <br /> PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for <br /> use with fire retardant,preservative treated,or green lumber. <br /> ICC-ES Reports: <br /> The first dimension is the plate 10.Camber is a non-structural consideration and is the <br /> 4 x 4 width measured perpendicular ESR-1311,ESR-1352,ESR1988 responsibility of truss fabricator.General practice is to <br /> to slots.Second dimension is ER-3907,ESR-2362,ESR-1397,ESR-3282 camber for dead load deflection. <br /> the length parallel to slots. 11.Plate type,size,orientation and location dimensions <br /> indicated are minimum plating requirements. <br /> LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and <br /> in all respects,equal to or better than that <br /> I,41111Indicated by symbol shown and/or Trusses are designed for wind loads in the plane of the specified. <br /> by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at <br /> output. Use T or I bracing spacing indicated on design. <br /> if indicated. Lumber design values are in accordance with ANSI/TPI 1 <br /> 14.Bottom chords require lateral bracing at 10 ft.spacing, <br /> section 6.3 These truss designs rely on lumber values or less,if no ceiling is installed,unless otherwise noted. <br /> BEARING established by others. <br /> 15.Connections not shown are the responsibility of others. <br /> II Indicates location where bearings 16.Do not cut or alter truss member or plate without prior <br /> (supports)occur. Icons vary but ©2012 MIMIC)All Rights Reserved approval of an engineer. <br /> *IMO reaction section indicates joint <br /> - number where bearings occur. 17.Install and load vertically unless indicated otherwise. <br /> Min size shown is for crushing only. 1111111111111111 <br /> ..-=-911 wit18.Use of green or treated lumber may pose unacceptable <br /> _� environmental,health or performance risks.Consult with <br /> project engineer before use. <br /> Industry Standards: <br /> ANSI/TPI1: National Design Specification for Metal 19.Review all portions of this design(front,back,words <br /> Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone <br /> DSB-89: Design Standard for Bracing. Mis not sufficient. _._. <br /> BCSI: Building Component Safety Information, i1'e�� 20.Design assumes anufacture in accordance with <br /> Guide to Good Practice for Handling, ANSI/TPI 1 QualityCriteria. <br /> Installing&Bracing of Metal Plate <br /> 4 Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.10/03/2015 <br /> A <br />