My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9930 19TH AVE SE 2019-11-15
>
Address Records
>
19TH AVE SE
>
9930
>
9930 19TH AVE SE 2019-11-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2019 9:49:07 AM
Creation date
11/15/2019 9:47:17 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9930
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Interior Lighting - S free-By-Space Method LTG-INT-SPACE, <br /> « 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: Wendy's Interior Dining Room/Toilet Room Tenant Improvement Date 10/9/2018 <br /> CalculationAQ Q Addition- O Addition For Building Department Use <br /> Ar ea NOTE 9 stand alone +existing <br /> Q Spaces where<50%of Q Spaces where>_50%of Q <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard 0 Additional Efficiency Package Option Q <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage"OTE' <br /> Location(plan#, Height"'''' Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ft2 x area) <br /> Toilet Men's Restroom:all other 8'-0" 232 0.780 181 <br /> Women's <br /> Service Counter Food preparation 7'-10" 104 0.790 82 <br /> 104 <br /> Dining Rm 100 Dining area:Bar/lounge/leisure dining 7'-10" 1874 0.8 60 1612 <br /> Total Area 2210 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 8 Allowed Watts 1875 <br /> Proposed Lighting Wattage"°rr s <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,5,6 Fixtures Fixture NOTE 7 Proposed <br /> Toilet 102,103 RECESSED CAN LIGHT, 10W, LED 4 40 160 <br /> Service Counter LSI 2x4 LED 2 lamp troffer 3 40 120 <br /> 104 <br /> Dining 100 2x4 -LED TROFFER-5000 Lumens-38watt-4000k-center 23 38 874 <br /> basket Diva Light TR46-46L-40K-d10 <br /> Didning 100 UM-4 1 60 60 <br /> Dining 100 Al can light LED 4 10 40 <br /> Dining 100 UM2-Track Light 6 60 360 <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 1614 <br /> Interior Lighting Power Allowance COMPLIE6 <br /> Note 1-List all unique space types per Table C405.4.2(2)that occur in the project scope.Select space type category per from drop down menu. <br /> Note 2-Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2),Footnotes d thru f. <br /> Note 3-List all proposed lighting fixtures including exempt lighting equipment and existing-to-remain fixtures. <br /> Note 4-For proposed Fixture Description,indicate fixture type,lamp type(e.g. T-8),number of lamps in the fixture,and ballast type(if included).For <br /> track lighting,list the length of the track(in feet)in addition to the fixture,lamp,and ballast information. <br /> Note 5-For lighting equipment eligible for exemption per C405.4.1,note exception number and leave Watts/Fixture blank. <br /> Note 6-Existing-to-remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures.Identify as existing <br /> in fixture description. <br /> Note 7-For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source.For <br /> luminaires with screw-in lamps,enter the manufacturer's listed maximum input wattage of the fixture(not the lamp wattage).For low voltage <br /> lighting,enter the wattage of the transformer.For line voltage track/busway systems,enter the larger of the attached luminaire wattage or 50 <br /> watts/lineal foot,or enter the wattage limit of permanent current limiting device. <br /> Note 8-Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. <br /> Note 9-Calculation Area Details: <br /> a.Lighting fixtures in a building addition may comply as a stand alone project,or they may be combined with the overall existing building <br /> lighting systems to demonstrate compliance.Refer to C502.1. <br /> b.For alterations and building additions,provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table.If a <br /> building addition will comply as combined with the overall existing building lighting systems,include all applicable existing Space Types <br /> and gross interior areas. <br /> c. If less than 50%of existing lighting fixtures will be replaced,provide total existing lighting wattage(prior to alteration)in the space provided / <br />
The URL can be used to link to this page
Your browser does not support the video tag.