INTERIOR <br /> WALL TYPE <br /> SIZE $1ZE <br /> r ► <br /> 1.Nominal wood stud thickness per plan. <br /> I,- an CONSTRUCTION <br /> �2 1. 2x wood studs spaced 16"o.c. unless noted otherwise. See structural <br /> drawings.In case of a conflict,the more stringent spacing applies. <br /> C4 ii O 2. 5/8" Type 'X' GWB each side. One layer 5/8" type 'X' GWB applied <br /> parallel to resilient channels (R.C.) 24"o.c. w/Type S drywall screws at <br /> glill II edges 6"o.c. and center row 12"o.c. End joints backblocked w/ R.C.. <br /> V-7 <br /> R.C.O R.C.attached at right angles to wood framing w/6d coated nails, 17/8" <br /> long, 0.086" shank, I/4" heads, 1/2"x3" GWB filler strip attached to <br /> plate at floor line w/6d nails as described above 16"o.c. Opposite side, <br /> 4O (1) layer GWB type 'X' applied at right angle to studs w/ 6d nails as <br /> • allimi described above 8"o.c.Stagger end joints 48"o,c.each side. <br /> 3. Resilient channels one side horizontally at 24"o.c. <br /> 411111°.11,�,�,,� 0 4. Plywood sheathing where indicated with a'P' modifier on the floor plan <br /> �p wall types.See structural drawings for type,size,and which face of wall <br /> to apply sheathing. Note: Plywood must always be on the opposite side <br /> of the studs as the resilient channels. <br /> 5. Sound batt insulation to the full height of the wall unless noted with an <br /> 'X' modifier on the floor plan wall types. 'X' modifier indicates sound <br /> insulation is not required. Use 3 1/2" bans at 2x4 walls and 6" batts at <br /> 2x6 or wider walls. <br /> 6. Finishes as scheduled(not shown). <br /> HEIGHT <br /> 1. Floor or foundation, as applicable, continuous up to 6" above finished <br /> ceiling. See wall sections,details and structural drawings for connection <br /> and termination requirements. <br /> FIRE RATING <br /> 1.Onehour fire rating per GA File No.WP 3230. <br /> SOUND RATING <br /> 1.STC 50 to 54 with 2x4 studs,per GA File No.WP 3230. <br /> Notes: <br /> 1. See `Notes to Wall Types and Sections' for additional requirements and <br /> information, <br /> 2.See'Wall Details'section 33 for additional requirements and information. <br /> 3.GWB to full height of wall unless noted otherwise. <br /> 4.Use W.R.GWB at restrooms,bathrooms,toilet rooms,laundry rooms <br /> and as scheduled,typical. <br /> FILE NO. 3204.DOC <br /> AR TS INTERIOR WALL TYPES PROM= <br /> 1: 9604 Drawing No. y (a <br /> , REED <br /> RE�NALD D+� 1.16.98 nn <br /> 1r 210HHl SILVER LAKE A.L.F. BY: 32•V S <br /> WS sicv'" r Slue Columbia Pacific MOONS <br /> jmm <br /> ill��ot SDohio*nish County.WA _ <br />