My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
333 SW EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
>
Address Records
>
SW EVERETT MALL WAY
>
333
>
BASE FILE
>
333 SW EVERETT MALL WAY BASE FILE 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/18/2019 2:43:10 PM
Creation date
11/18/2019 11:37:04 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
333
Tenant Name
BASE FILE
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
119
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL N01'ES <br />CODE: UNIFORM BUILDING CODE - � �� <br />i.ATF_:RAi. L.OADS � �,,,."' <br />BASIC WIND SPEED 80 MPI-I, �XPOSURE "" <br />SEISMIC ZONE 3 <br />M�CilU.lr7:��[�)�� <br />ALLOWABLE FOOTING BEARING PRESSURE ASSUMED TO BE: <br />2.0 KSF ON IiARD UNDISTURBED NATIVC SOILS <br />LATERAL EARTH PRESSUIiB <br />PASSIVE 200 PCr �QUIVALENT PLUID PRESSURE <br />BASE FRICTION COEFPICIENT 035 <br />MIX SUBMITTALS SHALL MEGT UBC OR ACI-318 STANDARDS IN ESTABLISHING <br />PROPORTIONS FOR SPECIPIED STRCNGTH. <br />CONCRETE SLUMP TO BE 4". DO NOT ADD WATER TO MIX TO 1NCREASE SLUMP. <br />GREATER SLUMI', ACC�L�RATED SET, OR HIGH EARLY STRENGTH MAY BE <br />ACHIEVED BY USING ENGINEER APPROVED ADMIXTURES. <br />MINIMUM CONCRETE ST12�NGTH AT 28 DAYS. <br />ALL FOOTINGS AND FOUNDATIONS 2500 PSI <br />MIXING AND PLACING OF ALL CONCRETF ANll SEL�CTION OF MATERIALS <br />SHALL BE IN ACCORDANCG WI1'H THE UBC, AND ACI CODE 318-89. PROPORTIONS <br />OP AGGREGATG TO CEMGN"I' SI-IALL BE SUCI I AS 7'O I'RODUCG A D�NSC <br />WORKABLG MIX WHICI-I CAN 13C PLAC�D WPCI-IOU"1' S�GREGATION OR �XCESS <br />FRG� SURFACE WAT�R. <br />( I► • : ► <br />ALL CONCRET� REINFORCING STEGL SIiALL BE D�PORMED PER ASTM A615, <br />GRADE 60 (FY=60,000 PSI). LAP CONTINUOUS REINFORCING BAR3 30 BAR <br />DIAMETERS, 1'-7" MMIMUM UNLESS OTHERWISE NO'fED. CORNER BARS SHALL <br />BE PROVIDED FOR ALL HORIZONTAL REINFORCEMENT. DETAIL STEEL IN <br />ACCORDANCE WITH THE "ACI MANUAL OF STANDARD PRACTICE OF DETAILING <br />REINFORCED CONCRETE STRUCTURES." <br />COVER TO MAIN REINFORCEMENT TO BE: <br />CONCRETE CAST' AGAINST EARTH 3" <br />CONCRETE EXPOSED TO EARTH (JR WGA1'HER <br />#5 B.�.R AND SMALLER 1-1/2" <br />