Laserfiche WebLink
�� SNOHOMISH <br />HEALTH <br />DISTRICT <br />June17,2011 <br />Laurcn Bivins <br />Harbor Marine <br />1032 W Marine Dr <br />Marysville, WA 98270 <br />ENVIRONMENTAL HEALTH DIVISION <br />3020 RuckerAvenue, Suite 104 <br />Everett, WA98201-3900 <br />425.339.5250 FAX:425.339.5254 <br />Deaf/Hard oi Hearing� 425.339.5252 (TTl') <br />Subject: Proposed Harbor Marine, 1032 W Marine View Dr, Fvere.t 98201 <br />Dear Mr. Bivins: <br />Your plans have been reviewed with the Rules and ! <br />with the policies of the Snohomish Health District. ' <br />the Plans submitted on June 16, 201; are approved. <br />2. <br />3. <br />C� <br />5. <br />F� <br />and <br />The Health District operating permit application process must be completeq prior to <br />opening for business. This w�ll have a limited grocery low risk permit and a Food <br />Service Establishment medium risk permit with 0-13 seats. <br />An indirect waste drain is required for the food preparation sink, three-compartment <br />sink, mechanical dishwasher, ice machine, pop dispenser, running water dipper well, <br />steam table, walk-in refrigeration, and any equipment m•vhich food is placed. <br />Water heaters must be of sufficient size to provide hot water to dishwasher and/or <br />scullery sinks and at the same time provide hot water to all handwash sinks. Hot water <br />must be available to all handwash sinks within 15 seconds. 7'he hot water for the <br />facility must not be used, at any plumbing fixture, for a minimum of 6 hours prior to <br />the preoperational inspection. This is required so that proper testing of the 15-second <br />time requirement for hot H�ater availability can be r,ompleted. <br />All food service equipment, both new and used, must be listed by the Nariona( <br />Sanitaiion Foundation (NSF) or equivalent for its intended use. Used and new <br />refrigeration must be capable of holding potentially hazardous food at 41 °F or below. <br />Used equipment is subject to onsite inspection to determine acceptability for use in the <br />proposed food service establishment. Used equipment must be clean, in proper <br />operating condition, and in good repair. Used refrigeration must be capable of holding <br />potentially hazardous foods at a temperature of 41 °F or below. <br />Extra wall protection is required on walls behind all sinks, including restroom <br />handwash sinks, nnd food preparation counters and tables. A 16-inch high backsplash <br />of plastic laminate, fiberglass-reinforced plastic or equal is acceptable. A backsplash <br />higher than 16 inches is required on the wall behind counter top equipment taller than <br />16 inches. Floor to ceiling protection is required on the wall behmd dishwashers. Wall <br />protection behind mop sinks must cover the entire splash zone. Plastic coated <br />hardboard is not acceptable. <br />All Iloors in the kitchen, food preparation, food service, food storage, and dishwashing <br />areas must be surfaced with a durable, nonabsorbent, easily cleanable mr,terial. <br />Eapansion joints, seams, saw cuts and the like in concrete floors in all areas, including <br />customer scating arens, must be filled and sealed so as to provide a smooth and <br />cleanable surface. <br />. � <br />