My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1316 WALL ST STERLING REFERENCE LABS 2018-01-01 MF Import
>
Address Records
>
WALL ST
>
1316
>
STERLING REFERENCE LABS
>
1316 WALL ST STERLING REFERENCE LABS 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2019 9:01:12 AM
Creation date
11/26/2019 9:00:05 AM
Metadata
Fields
Template:
Address Document
Street Name
WALL ST
Street Number
1316
Tenant Name
STERLING REFERENCE LABS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
W A S H I N G T G N <br />ARCMITECTUPnL <br />HARDWARE CO. <br />ICC/Ansi Al 17.1 -20G i <br />Accessible & Usable Buildings & Pacilities <br />New Crab Bar Requirements <br />64i.:;.1 Fixed Side Well Grah Bars. Fixed <br />sidew¢II grab bars sh¢II 6e 42 inches !7065 <br />mm) minimum in lengih, located 12 inches (305 <br />mm) maximum from the reer wall end axtending <br />S�i inches (7370 mm) minimum hom lhe rear <br />wall, in ndditian, e verticui �rah ber iB inches <br />(455 mm) minimum in length shall be mounted <br />with the boriom at ihe bar locnted between 39 <br />inches (sso mm) nnd a� inchos (to4o mm) <br />ebove the floor, and with the center lir,a ol the <br />bar IecateA botween 39 inches (990 mm) and <br />41 inches (1040 mm) 6om the rear well. <br />EXCEPTIONS: <br />t. In Typo A und Typo B units, the vertical <br />grob bor componenl is not required. <br />2. In a Type 8 unit, when a=_'�e wall is not <br />availatle tor a 42-inch (1065 mm) grab <br />bar, Ihe sidewall grab bar shallbe per- <br />mitted to be 1B inches (455 mm) mini- <br />mum in length, lacated 12 iaches (305 <br />mm) maximum fiom the rear wall and <br />extending 30 inches �760 mm) mini� <br />mum from the rear wall. <br />�9-41 <br />990 - t040 EI N <br />Sa min p <br />0 <br />12 max� 1370 A <br />3C5 . ._ II �� <br />a2 min <br />Secnan fi09.4 \ <br />� <br />� <br />n rn <br />i <br />nlo <br />� c <br />Fig. 5oa.s.t <br />Side Wall Grab Bar for Water Closet <br />u <br />a <br />6CW.5.2 Rear Wall Grab Bars. The rear wall <br />grab bar shall be 36 inches (915 mm) minimum <br />in length, and extend from the centerline of the <br />water claset 72 inches (305 mm} minimum on <br />the side closesi to Ihe wall, and 24 inches (610 <br />mm) mmimum on the transfer side. <br />EXCEP TIONS: <br />2. <br />3. <br />The rear grab har shall be permitted lo <br />be 24 inches (fi10 mm) minimum in <br />length, centered an the water closet, <br />where wall space does not permii agrab <br />bar 36 inches (915 mm) minimum in <br />length due to the Iocatian of a rxessed <br />fixture adjacent to the water closel. <br />In a Type A or Type 8 unii, the rear grab <br />bar shall be permitted to be 24 inches <br />(610 mm) minimum in length, centered <br />on the water closel, where wall spac: <br />does not permit a greb bar 36 inches <br />(915 mm) mmimum in lengtti. <br />�Vhere an administrative eulhority re� <br />quires Hush conUols for flush valves to <br />bc located in a position Nat conflicts <br />wilh ihe location of Ihe rear grab bar, <br />that grab bar shall be permitted to be <br />splitor shihed ta the open side of the toi- <br />let area. <br />�6 mm <br />91� . .12min <br />24 min � , �OS <br />610 � I � <br />� <br />'�_ '-=� <br />v <br />�n ai <br />�I a <br />n c� in <br />i c <br />� o 0 <br />� r � <br />a y <br />N <br />Fig. fiO4.5.2 <br />Rcar Walt Grab Bar inr Water Ciaset <br />�1a09��uthOrrhard5ueet • lamrna,NJA9�46b • Phone�2 531 4 /1-9150 • Fax(2 531 471-9171 • wHnv.wah-usa.eom �y� <br />
The URL can be used to link to this page
Your browser does not support the video tag.