Laserfiche WebLink
Jn12 waahinatnn Stale Fnerov Code comoliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all <br />Project Info <br />Project Address Tectaon. sto c, .cot <br />Dale 4/22/7014 <br />2631 Walnut St <br />Far Budding Department Use <br />Compliance forms <br />do not require <br />�1 �105- 00� <br />Evi 'tt' WA <br />password to use. <br />tnsbupionaland <br />Apphcanl Name. <br />Applicant Address <br />calculating cells are <br />write -protected. <br />Applicant Phone. <br />Project Description <br />❑ New Building ❑ Addition ❑ Alteration ❑ Change of Cs; cancy/Condition nW <br />Compliance Path <br />O Prescriptive Component Performance O Total Building Performance <br />Selection required to enable forms. <br />Occupancy Group <br />Commercial O Group R - R2 & R3 over 3 stones and all RI <br />Selection requred to enable roans. <br />1 <br />Gross Exterior <br />Vertical Fenestration and <br />Total Vertical <br />Skylight Area Calculation <br />Fenestration Above Grade %Vertical <br />(rough opening) divided by Wall Area times 100 equals Fenestration <br />If complying via the Prescriptive path, <br />enter values for vortical fenestration. <br />X 100 = <br />skyli gross walls and root on this <br />Gross Exterior <br />ENV-SUMworksheef, Itcomplyingwa <br />the Component Performance path, enter <br />these values in the ENV-UA worksheet. <br />Total Skylight divided b Roof Area times 100 equals %Sk i- hl <br />y Y� q <br />X 100 = <br />These values auto -fill from ENV-UA and <br />are wnto-protecred on ENV -SUM.— <br />Vertical <br />Fenestration Area <br />Fenestration Area <br />Compliance <br />Skylight Area <br />Vertical Fenestration <br />O 5090 or more of the floor area iswithin a daylight zone per C40231.1 <br />Alternates <br />O High Performance Fenestration U-factors and SHGC per C402.3.1.3 <br />CompliancekMethod <br />0 Skylight area 390 or greater, V7•0.40 or greater <br />Al <br />Single Story Spaces <br />❑ Skylight effective aperture 1% or greater, provide calculation <br />Requiring Skylights <br />❑ Space eligible for exception <br />Requires a minimum of 5065 of floor area to be within a skylight daylight zone tar specific <br />space types. Refer to C402 3 2 for requirements. <br />❑ Project has semiheated spaces as defined per C402.1 4 <br />❑ Applying wall exception to semi -heated spaces <br />I. Somhheated spaces may comply under Prescriptive or Component Performance compliance <br />Semi -Heated Spaces <br />path. <br />I <br />2. Semi-hoafod spaces shall be documented separately from other conditioned spaces - provide <br />separate compliance forms for each conditioned space type. <br />3. Envelope elements separating semi -heated from other conditioned spaces shall comply with <br />exterior thermal envelope requirements <br />ri <br />❑' Walk-in Cooler ❑' Walk-in Freezer <br />❑ Refrigerated Warehouse Cooler ❑ Refrigerated Warehouse Freezer <br />Refrigerated Spaces <br />Refrigerated spaces shall comply under the Prescriptive Path only. Compliance documentation for <br />those areas may be combined with non -refrigerated areas in the ENV -PRESCRIPTIVE form. Refer <br />to C402 5 and C402.6 for requoements. <br />Project includes more than one occupancy type and/or level of space conditioning Mulliple <br />Mixed Occupancy .I IIdti or <br />compliance forms may be required. Select all that apply to scope of project <br />Space Conditioning <br />❑ Commercial ❑ R2&R3over3storiesandall Rl ❑ Refrigerated Space <br />❑ Fully Conditioned ❑ Semi -Heated ❑ Low Energy' <br />❑ R2& R3. 3 stories or less <br />'Low energy areas are exempt from all thermal envelope provisions and compliance forms for <br />These areas are not required Refer to C101.5.2 for exemption <br />s-9 <br />