Laserfiche WebLink
11. No manufacturer or model number was submitted for the cold crock container. Prior to the request <br />for the preoperational inspection a manufacturer and model number for the cold crock container <br />must be submitted. The model number must be found to be certified by NSF or equivalent. If <br />verification o( NSF or equivalent certification for the cold crock container cannot be given by the <br />;ime of the request for a preoperational inspection the cold crock container may not be approved for <br />use in the proposed food establishment ' _ <br />12. This facility has only one 2-door upright food storage refrigerator (48 cubic feet). This does not meet <br />the Health District minimum �efrigeration requirement of 144 cubic feet of refrigerated storage. <br />Based upon the information submitted on June 18, 2014, and menu submitted RNay 23, 2014, <br />a variance to aliow a reduced amount of refrigeration has been grented. This variance is for <br />the current operation only and is non-transferable. If during routine inspections it is found that the <br />current amount of refrigeration is inadequate for the refrigerated storage needs oi the facility, then <br />the number of inenu items must be reduced to a level acceptable for the facility's amount of <br />refrigeration. The menu item reduction will remain in effect until such time as additional refrigeration <br />is installed and approved by the Health District Changes in the food preparation process may also <br />be required if deemed a contributing factor for inadequate refrigeration. <br />13. This facility has a limited amount of reach-in retrigeration equipment. No advanced preparation of <br />foods that require cooling will be ailowed unless a walk-in refrigerator or blast chiller (rapid <br />temperature pull down refrigerator) is installed or other rlealth District approved cooling method is in <br />place. Approval of cooling methods other than in a walk-in refrigerator must be approved prior to <br />final plan approval. Any proposed cooling method must be included in required description of the <br />food preparation process. Please note that if any approval for cooling o( food is given, the risk <br />classification for the establishment will change to a high-risk food establishment and an additionai <br />permit fee for the classification change will be charged. <br />14. E�tra wall protection is required on walls behind all sinks, including restroom handwash sinks, and <br />food preparation counters and tables. A 16-inch high backsplash of plastic lami�ate, fiberglass- <br />reinforced plas;ic or equal is acceptable. A backsplash higher ;han 1G inchas is required on the wall <br />behind counter top equipment taller than 16 inches. Floor to ceiling protection is required on the <br />wall behind dish�vashers. Wall protection behind mop sinks must cover the entire splash zone. <br />Plastic coated hardboard is not acceptable. <br />15. All floors in the kitchen, food preparation, food service, food storage, and �ishwashing areas must <br />be surfaced with a durable, nonabsorbent, easily cleanable material. Expansion joints, seams, saw <br />cuts and the like in concrete floors in ail areas, including customer seating areas, must be filled and <br />sealed so as to provide a smooth and cleanable sur(ace. <br />16. The ceiling above the food preparation areas must be non-perforated, nonabsorbent, smooth and <br />easily cleanable. <br />17. Cabinet shelving must be nonabsoruent, smooth and easily cleanable. (Self stick vinyl or other type <br />surfaces are not acceptable) <br />18. All light fixtures in food preparation and storage areas must be provided with covers and <br />shatterproof bulbs. Hot hotd unit heat lamps must be provided with shatterproof bulbs. <br />19. Plumbing must meet state and local codes. <br />20. The ventilation system shall be installed and operated to meet applicabl� building, mechanical, and <br />fire codes. <br />21. All food available for customer sel( service in the breakfast area must be prolected from potential <br />contamination by the use of packaging, display cases, covers, serving Iine sneeze guard protectors, <br />dispensers or by other effective means. <br />A preoperational inspection is required prior to opereting permit issuance and approval to open <br />for business. At the time of inspection the construction of the food service establishment must be <br />complete and all equipment must be in place and in proper operating condition. Incomplete construction <br />or equipment operation wiil result in a$168.00 re-inspection fee. Contact the Food Program o�ce a <br />minimum of one week in advance to schedule an appointment for the preoperational inspection. <br />�1� <br />