My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE SEATTLE MASSAGE SCHOOL 2018-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
2721
>
SEATTLE MASSAGE SCHOOL
>
2721 WETMORE AVE SEATTLE MASSAGE SCHOOL 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2019 9:03:08 AM
Creation date
12/2/2019 9:00:52 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
SEATTLE MASSAGE SCHOOL
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. George Casady <br /> February 12, 1993 <br /> Page 2 of 3 <br /> ✓10. Walls and ceilings of corridors are required to be of 1-HR fire-resistive <br /> conswction. Section 3305(g). An az�chitectural section through the corcidor is <br /> necessary to determine how this is accomplished. <br /> ✓ 11. Interior openings into corridors are required to be protected as set forth in <br /> Section 3305(h). Self-closing or automatic closing twenty-minute rated door <br /> assemblies properly gasketed shouid be provided. Other openings are limited to <br /> 3/4-HR rated fixed glazing and shall not excced 2590 of the azea of the common <br /> wali. <br /> ✓ 12. All doorways leading to accessible rooms shall have an unobstructed clear width <br /> of not less than 32 inches. Section 3106(j). <br /> l�� 13. Accessible doors shall have maneuvering clearances per Section 3106(j)3. <br /> i/14. A clear circulaz unobstnicted floor space 60 inches in diametcr within the toilet <br /> room is required. Doo:s may encroach into this space by not more than 12 <br /> inches. Section 3106(k)2. <br /> r�15. Provide grab bazs per Section 3106(k)5c and 3106(k)11. <br /> ✓16. A clear space 30 inches wide, 29 inches high znd 17 inches in depth shall be <br /> provided under each lavatory. Section 3106(k)7c. A clear floor space not less <br /> than 30 inches wide and 48 inches deep is required in front of lavatories and <br /> sinks. Section 3106(k)7a. <br /> �17. The bottom of at least one mir shall be within 40 inches of the floor. Secdon <br /> 3105(b)3 and 3106(k)8. <br /> ✓18. Hand drying equipment and toilet accessories shall be placed within 40 inches of <br /> the tloor. Section 3106(k)8. <br /> ✓19. Provide signage per Section 3106(p) to accessible parking spaces, entrances <br /> (when not all entrances aze accessible), toilet and bathing facilities (when not all <br /> are accessible) and at every major junction along or leading to an exterior <br /> accessible route of travel. Secdon 3103(b)4. <br /> �20. Controls, operadng mechanisms and hazdware shall be accessible in accordance <br /> with Section 3106(c). Section 3105(d)8. <br /> N� 21. Alarm systems shall include both audible and visible alarms and shall be located <br /> per Section 3105(d)9. <br />
The URL can be used to link to this page
Your browser does not support the video tag.