Laserfiche WebLink
Mr. George Casady <br /> February 12, 1993 <br /> Page 2 of 3 <br /> ✓10. Walls and ceilings of corridors are required to be of 1-HR fire-resistive <br /> conswction. Section 3305(g). An az�chitectural section through the corcidor is <br /> necessary to determine how this is accomplished. <br /> ✓ 11. Interior openings into corridors are required to be protected as set forth in <br /> Section 3305(h). Self-closing or automatic closing twenty-minute rated door <br /> assemblies properly gasketed shouid be provided. Other openings are limited to <br /> 3/4-HR rated fixed glazing and shall not excced 2590 of the azea of the common <br /> wali. <br /> ✓ 12. All doorways leading to accessible rooms shall have an unobstructed clear width <br /> of not less than 32 inches. Section 3106(j). <br /> l�� 13. Accessible doors shall have maneuvering clearances per Section 3106(j)3. <br /> i/14. A clear circulaz unobstnicted floor space 60 inches in diametcr within the toilet <br /> room is required. Doo:s may encroach into this space by not more than 12 <br /> inches. Section 3106(k)2. <br /> r�15. Provide grab bazs per Section 3106(k)5c and 3106(k)11. <br /> ✓16. A clear space 30 inches wide, 29 inches high znd 17 inches in depth shall be <br /> provided under each lavatory. Section 3106(k)7c. A clear floor space not less <br /> than 30 inches wide and 48 inches deep is required in front of lavatories and <br /> sinks. Section 3106(k)7a. <br /> �17. The bottom of at least one mir shall be within 40 inches of the floor. Secdon <br /> 3105(b)3 and 3106(k)8. <br /> ✓18. Hand drying equipment and toilet accessories shall be placed within 40 inches of <br /> the tloor. Section 3106(k)8. <br /> ✓19. Provide signage per Section 3106(p) to accessible parking spaces, entrances <br /> (when not all entrances aze accessible), toilet and bathing facilities (when not all <br /> are accessible) and at every major junction along or leading to an exterior <br /> accessible route of travel. Secdon 3103(b)4. <br /> �20. Controls, operadng mechanisms and hazdware shall be accessible in accordance <br /> with Section 3106(c). Section 3105(d)8. <br /> N� 21. Alarm systems shall include both audible and visible alarms and shall be located <br /> per Section 3105(d)9. <br />