My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2821 WETMORE AVE TUOHY KRUSE MINOR PLLC 2018-01-01 MF Import
>
Address Records
>
WETMORE AVE
>
2821
>
TUOHY KRUSE MINOR PLLC
>
2821 WETMORE AVE TUOHY KRUSE MINOR PLLC 2018-01-01 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/2/2019 11:01:35 AM
Creation date
12/2/2019 10:55:32 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2821
Tenant Name
TUOHY KRUSE MINOR PLLC
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
88
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
:: <br />✓ 6 The non-absorbent floor and base in the toilet room should be indicated as a <br />smooth, hard suAace that extends up the walls by srx inches, per IBC section <br />1210. Typically sheet vinyl or ceramic tile is indicated to meet this requirement. <br />ADDED note "SMOOTH, HARD, NON-ABSORBENT SURFACE EXTENDING 6" <br />UP THE WALL, TYP." to both enlarged plan and interior elevations. Client was <br />not sure of material at the time of pertnitting. <br />, j 7 the ceiling details should comply with the attached Field Technicai Information <br />Publication 401, dafed June 2005...in regards [o the support and bracing of fhe <br />ceiling systems, including 2' wide wall angies at fhe ceiling termination. <br />ADDED ceiling details t thru 4/A-9 to depict ceiling suppoA and bracing system. <br />Note: BERC2 was substituted for the 2" wall angles. <br />8 Partitions should be detailed on fhe drawings fo indicate that fhe partition over six <br />/eet high have adequate strength to resisf the loads to which they are subjecfed, <br />but not /ess than a horizontal load o/ 5ps/, per IBC secfion 1607.13. <br />ADDED Detail 61A-8 lo show partition bracing for walls over 6 feet in height. <br />9 The basement ceiling height should be indicated on the drawings including the <br />� minimum Gearance t the underside of strucfure. To be used as storage, the <br />mrnimum required dear height is 7'-0', the unused area should be ident�ed as <br />sforage or not habitable space. All other occupiable and habifa6le spaces in the <br />basement should have a ceiling height o/ 7'-6', per ISC section 1208.2. <br />ADDED nole indicating the area is STORAGE and the ceiling height is 7'-0" clear <br />on basement Plan on Sheel A-9. Also, note was added indicating that minimum <br />clear height of 7'-0" is to be used as Storage (not habitable space), 7'�" is <br />required foi habitable space per IBC section 72082. <br />4474 <br />END OF COMMENT RESPONSE <br />REGISTERED <br />OF <br />. t��.' G;� rt,� C-�a��n.,,Y �io_.�;�ris�: <br />P�..�fi�.._.,'J.� 9�h5E:._, <br />A-7 <br />A-9 <br />A-8 <br />A-5 <br />Date Ofi2E2007 <br />pege 2 of 2 <br />