My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1304 80TH ST SW EVERETT SCHOOL DISTRICT 2018-01-02 MF Import
>
Address Records
>
80TH ST SW
>
1304
>
EVERETT SCHOOL DISTRICT
>
1304 80TH ST SW EVERETT SCHOOL DISTRICT 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2019 7:26:51 AM
Creation date
12/12/2019 7:07:29 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1304
Tenant Name
EVERETT SCHOOL DISTRICT
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
337
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E.S.D. BUS FACILITY <br /> DETENTION TANK CALCULATIONS <br /> SUMMARY OF INPUT ITEMS <br /> 1) TYPE OF FACILITY: TANK <br /> P.) TANK DIAMETER(ft) , STORAGE DEPTH(ft) : 8.00, 4.25 <br /> 3) VERTICAL PERMEABILITY(min/in) : .00 <br /> 4) PRIMARY DESIGN HYDROGRAPH FILENAME: 100yd <br /> 5) PRIMARY RELEASE RATE(cfs) : 2.65 <br /> 6) NUMBER OF TEST HYDROGRAPHS: 2 <br /> TEST HYD 1 FILENAME: lOyd TARGET RELEASE(Cfs) : 1.29 <br /> TEST HYD 2 FILENAME: 2yd TARGET RELEASE(cfs) : .25 <br /> 7) NUMBER-OF-ORIFICES, RISER-HEAD(ft) , RISER-DIAM(in) : 2, 4.25, 18 <br /> 8) ITERATION DISPLAY: NO <br /> BOTTOM ORIFICE: ENTER Q-MAX(cfs) <br /> 0.29 <br /> DIA.= 2.28 INC14ES <br /> TOP ORIFICE: ENTER []EIGHT(f t) <br /> 3.2 <br /> DIA.= 9.22 INCHES <br /> PERFORMANCE: INFLOW TARGET-OUTFLOW ACTUAL-OUTFLOW PK-STAGE STORAGE <br /> DESIGN HYD: 4.29 2.65 2.64 4.24 13055 <br /> TEST HYD 1: 2.88 1.29 .57 3.26 11340 <br /> TEST HYD 2: 1.89 .25 .25 3.10 6340 <br /> SPECIFY: D - DOCUMENT, R - REVISE, F. - ADJUST ORIF, E - ENLARGE, S - STOP <br /> e <br /> ENLARGEMENT OPTION: ALLOWS FOR INCREASING STORAGE AT A SPECIFIED <br /> STAGE HEIGHT, TO PROVIDE A FACTOR OF SAFETY. <br /> ENTER: STORAGE-INCREASEW , STAGE-HEIGHT(ft) <br /> 45 4.25 <br /> PERFORMANCE: INFLOW TARGET-OUTFLC.- ACTUAL-01"i FLOW PK-STAGE STORAGE <br /> DESIGN HYD: 4.29 2.65 1 .13 3.37 16837 <br /> TEST HYD 1: 2.88 1.29 .25 3.19 15720 <br /> Ti-T HYD 2: 1.89 .25 .25 3.06 6360 <br /> Large diameter detention pipe r:.11 require 16,837 cf of storage. <br /> STRUCTURE DATA: R/D TANK (FLAT GRADE) <br /> RISER-HEAD TANK-DIAM STOR-DEPTH TANK-LENGTH STORAGE-VOLUME <br /> 4.25 FT 8.00 FT 4.25 FT 698.4 FT 18948 CU-FT <br /> DOUBLE ORIFICE RESTRICTOR: DiA(INCHES) HT(FEET) Q-MAX(CFS) <br /> BOTTOM ORIFICE: 2.28 .00 .290 <br /> TOP ORIFICE: 9.22 3.20 2.360 <br />