Laserfiche WebLink
.� � ( ( <br /> ATG-Everctt <br /> 1997 UDC Architecmral Synopsis <br /> Pa e2of3 <br /> Exterior poors and Windows: N <br /> Stairway Construction N -Not req'd to be enclosed when only 2 <br /> Floors connected 1005.3.3.1 <br /> c �' � �w►�Rwls�woco�s �: .- a. .:�T�r <br /> Section 708 FIRE BLOCKS AND DRAFT STOPS <br /> 708.1 General; re uired in combustible construction. <br /> 708.2 R uired fire blockin <br /> 708.3.1.1.3 Floor/ceilin assemblies dreft sto s—max. concealed area 1,000 sf. <br /> 708.3.1.2 Attic draft sto s—max. area 3 000 sf. <br /> Saction 712 Usabte s ace under floon <br /> Usable space under the first floor shall be enclosed and protected on the <br /> side of the usable space except where protected by an automatic sprinkler <br /> ;, stem. exce t. 1 <br /> , : • INTERIORFNiI�f1E8 , : �'�'"�;:,: �:�+�'...."�"�'".�d�.�.;.-�R-�?.•: . <br /> Seetion 804 MAXIMUM ALLOWABLE FLAME SPREAD <br /> Table 8-b Enclosed vertical exits; I <br /> Other exits; II <br /> Rooms and areas; III <br /> Section 807 SANITATION <br /> 807.1.1 Floois; Cove 800r u wall min. 5" <br /> 807.1.2 Walls; Wainscot on walls within 2'of front and sides of urinals and water <br /> closets to hei ht of 4' <br /> 'CHAPTER 9 :-'. ,FIRE�RO7'ECTJON81fs78M8' -",: "''}�. '=�: <br /> f.CHAPTER 10 � "' i OF'EdREBi ''' �tr�Y1�'�.i�..•�._ .'.,:5- ,� ; ,::t�:_'�i_ <br /> Section 1003 GENERAL <br /> 1003.2.3 WIDTH <br /> 7003.2.2.2. Occupant loadlfloor <br /> 2 Basement will have equipment that will need only occasional servicing and <br /> therefore is wnsidered an unoccupied space. <br /> Table 10-A Main Floor 5283 sf office/ 100= 53 occupants <br /> +Z7g4 sf inech/300=9 occupants =62 occupanWmaln floor <br /> Therefore, need hvo means of egress from Main Floor and one from <br /> Basement. <br /> 1003.2.3.2 Minimum width: TABLE 10-B. <br /> Stairvva s: 0.3 x 62= 18.6 inches, all other: 0.2 x 62= 12.4 inches. <br /> 1003.3.1 DOORS ' <br /> 7003.3.1.5 Swing; Swing in the direction of travel when the occupan!load is 50 or <br /> more. <br /> 1003.3.1.7 Landings; Not less than 44" in direction of travel. Width shall not be less <br /> than the width of the stainvay. When the occupant load is less than 50, the <br /> deor shall not reduce a re uired dimension b more then 7". <br /> 1003.3.3 STAIR\NAYS <br /> 1003.3.3.3 Max. rise: 7.5", min. run 10". Min rise 4". <br /> 1003.3.3.6 Handrails: both sides re uired. <br /> 1003.3.3.13 Stairwa identification not re uired since the ro ect is less than 4 stories. <br /> Section 1004 THE EXIT ACCESS <br /> 1004.2.2 TRAVEL THROUGH INTERVENING ROOMS <br /> Exception 2: Where only one exit is required from a space, exit access may <br /> occur through an adjoining or intervening room which in tum provides direct <br /> access to an exit or to a corridor. <br /> Exception 3: Rooms with a cumulative occupant load of less than 10 may <br /> access exits through more than one intervening room. <br /> Exception 4: Where access to more than one exit is required from a space, <br /> such spaces may access ane required exit through an adjoining or <br /> intervenin room. All other re uired access to exits shall be directl from <br />