My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7404 EVERGREEN WAY 2018 FIRST CHOICE HEALTHCARE Plans 2022-12-01
>
Address Records
>
EVERGREEN WAY
>
7404
>
FIRST CHOICE HEALTHCARE
>
Plans
>
7404 EVERGREEN WAY 2018 FIRST CHOICE HEALTHCARE Plans 2022-12-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/1/2022 3:53:40 PM
Creation date
1/2/2020 1:34:59 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
7404
Tenant Name
FIRST CHOICE HEALTHCARE
Permit
B1801-028
Year
2018
Notes
TI REMOVAL ADD NEW WALL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTE <br /> 1. VERIFY ALL CONDITIONS IN THE FIELD. <br /> 2. THESE DRAWINGS AND SPECIFICATIONS REPRESENT ONLY TI <br /> ARCHITECTURAL ASPECTS OF THIS PROJECT. ANY ADDITION� <br /> M.E.P. DRAWINGS, DOCUMENTATION AND/OR APPLICABLE <br /> PERMITS REQUIRED FOR THIS PROJECT WILL BE THE <br /> RESPONSIBILITY OF OTHER. <br /> �cu�rvu <br /> Q� RECESSED FIXTURE <br /> � � � TRACK LIGHTING <br /> 2'x4'FLUORESCENT <br /> 2'x4'FLUORESCENT <br /> NIGHT LIGHT FIXTURE <br /> 2'x2'FLUORESCENT <br /> (R) RELOCATED EXISTING FIXTURE <br /> (E) EXITING FIXTURE TO REMAIN <br /> (N) NEW FIXTURE <br /> s.o SMOKE DETECTOR <br /> REFLECTED CEILING NOTE LIGHTING SCHEDULE <br /> 1. LIGHTING SYSTEM IS SH�WN SCHEMATICALLY AND IS TO BE BIDDER DESIGNED TO MEET REQUIREMENTS OF <br /> OWNER, MECHANICAL SYSTEM, AND APPLICABLE CODES AND REQUIREMENTS. r�rPE DESCRIPTION MANUFACTURER MODEUPART#ITYPE u�►�P REMARK <br /> LF-1 RECESSED FIXTURE ROYAL PACIFIC 8123HAQ 23W RECESSED HOUSING <br /> 2. MECHANICAL SYSTEM SHALL BE BIDDER DESIGN TO MEET REQUIREMENTS OF OWNER APPLICABLE CODES AND ---- -_-- ____._ ___ <br /> REQUIREMENTS. <br /> LF-3 2X4 FLUORESCENT LIGHTOLIER 2'X4'-3-LAMP 34W 2X4 DROP IN <br /> 3. VERIFY NUMBER AND LOCATION OF SUPPLY REGISTERS WITH OWNER BEFORE PROCEEDING WITH WORK. �F-a 2X2 FLUORESCENT LI�HTOLIER 2�xa'-2-LAMP 2aw 2X2 DROP IN <br /> � <br /> 4. VERIFY NUMBER AND LOCATION OF RETURN REGISTERS WITH OWNER BEFORE PROCEEDING WITH WORK. *ALL FIXTURES LISTED ABOVE ARE FOR DESIGN PURPOSE ONLY. ACTUAL FIXTURE SHALL BE SELECTED BY THE <br /> ELECTRICAL CONTRACTOR WITH OWNER'S APPROVAL. E <br /> 5. PROVIDE SEISMIC BRACING FOR SUSPENDED CEILINGS PER DETAIL. •ALL OTHER LIGHT FIXTURES AND EXHAUST PAN ARE NOT LISTED ABOVE ARE FROM EXI5ITNG. <br /> (R) <br /> � <br /> (N)LF-1 <br /> UGHTING NOTES ELECTRICAL CALCULATION cR� tR� cR> <br /> PER 2015 WASHINGTON STATE ENERGY CODE: TABLE C405.4.2{2), LF-3 LF-3 LF-3 LF-3 <br /> 1. LIGHT SWITCHES SHALL BE INSTALLED 48"A.F.F. MULTIPLE SWITCHES SHOULD BE GANGED TOGETHER UNLESS INTERIOR LIGHTING POWER ALLOWANCE (LPD) <br /> OTHERWISE SPECIFIED. S� S.o S.o <br /> EXAM/TREATMENT ROOM - 1.33 WATT PER S.F. � <br /> 2. CONTRACTOR TO VERIFY ALL SWITCH LOCATIONS WITH TENANT PRIOR TO INSTALLATION. NUMBER OF PHYSICAL THERAPY ROOM -0.73 WATT PER S.F. <br /> SWITCHES FOR OPEN AREA IS BIDDER DESIGN. IMAGING ROOM(X-RAY} - 1.06 WATT PER S.F. <br /> LOBBY -0.72 WATT PER S.F. <br /> 3. CONTRACTOR SHALL PROVIDE EMERGENCY LIGHTING. STROBE LIGHTS, AUDIO VISUAL ALARMS, TO MEET ALL OFFICE -0.89 WATT PER S.F. (N�-� (N)�LF-1 <br /> APPLICABLE CODES. CORRIDOR- 0.53 WATT PER S.F. <br /> BREAK ROOM (KITCHEN) -0.74 WATT PER S.F. (E)2�x2'ACOUSTIC CEILING TILE �R� (R) <br /> EXISTING SUSPENDED CEILING TO LF-3 LF-3 <br /> 4. PROVIDE FIRE DAMPER AT ALL SUPPLY AND RETURN AIR OUTLETS, INLETS, OR DUCTS PENETRATING FIRE REMAIN.CLEAN GRID AND REPLACE <br /> RATED ASSEMBLIES, ENCLOSURE, WALLS, FLOORS OR SURFACES AND AS REQUIRED BY THE FIRE DEPARTMENT, TREATMENT ROOM: DAMAGED OR STAINED CEILING S.o <br /> IF APPLICABLE. 342 S.F. X 1.33 WATT=454.86 WATTAGE ALLOWED TILES AS REQUIRED <br /> LF-3: 34W X 4 FIXTURES = 136 WATT USED*OKAY (E) <br /> 5. ALL REQUIRED EXIT SIGN SHALL HAVE LETTERS SIX INCHES HIGH MINIMUM AND SHALL CONFORM WITH ALL SD <br /> LF-3 <br /> APPLICABLE CODES. PHYSICAL THERAPY ROOM (MASSAGE RM): � �R� <br /> 171 S.F. X 0.73 WATT= 124.83 WATTAGE ALLOWED <br /> 6. CONTRACTOR SHALL PROVIDE SEISMIC BRACING AT ALL RELOCATED LIGHT FIXTURES. LF-3: 34W X 2 FIXTURES = 68 WATT USED *OKAY LF-3 <br /> IMAGING ROOM (X-RAY): (N}�LF-1 (N)�LF-1 <br /> ELECTRICAL NOTES 119 S.F X 1.06 WATT = 126.14 WATTAGE ALLOWED ' �R� <br /> 1. EXTENSION OF EXISTING ELECTRICAL SYSTEM SHALL BE BIDDER DESIGN TO MEET THE REQUIREMENTS LF-3: 34W X 2 FIXTURES- 68 WATT USED *OKAY 5D <br /> LF-3 <br /> SHOWN, AND REQUIRED FOR LAWFUL AND PROPER INSTALLATION OF THE HIGHEST QUALITY. WORK SHALL LOBBY: (R) (R� <br /> CONFORM TO THE LATEST EDITION OF NATIONAL ELECTRIC CODE. STATE OF WASHINGTON ELECTRICAL CODE � <br /> AND ALL OTHER CODES APPLICABLE TO THE WORK DEVICES AND EQUIPMENT SHALL BE UNDERWRITER'S 160 S.F. X 0.72 WATT = 115.2 WATTAGE ALLOWED ! � __ __ __ <br /> LF-1: 23W X 3 FIXTURES = 69 W <br /> LABORATORIES, INC. LISTED AND LABELED, WHERE APPLICABLE. LF-3: 34W X 1 FIXTURE = 34 W LF-3 � � <br /> (N)LF-1 <br /> 2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN TOTAL, 103 WATTS USED *OKAY <br /> S.D <br /> CONTRACT INCLUDING APPROXIMATE LOCATION OF ALL NEW LIGHTING FIXTURES, OUTLETS, AND EQUIPMENT. OFFICE: � <br /> 3. GUARANTEE EACH SYSTEM IN ITS ENTIRETY AND ALL PARTS FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL 313 S.F. X 0.89 WATT= 278.57 WATTAGE ALLOWED �R� _-_- <br /> -- S.D <br /> LF-3: 34W X 4 FIXTURES - 136 WATT USED* OKAY <br /> ACCEPTANCE. - <br /> CORRIDOR: �R) <br /> 4. NEW SWITCH AND RECEPTACLES SHALL BE WHITE. _ (E�-� (E�-1 LF-3 <br /> 221 S.F. X 0.53 WATT 117.13 WATTAGE ALLOWED <br /> LF-1: 23 W X 5 FIXTURES = 115 WATT USED*OKAY �E} �E� <br /> 5. ALL WALL MOUNTED TELEPHONE AND ELECTRICAL OUTLETS TO BE INSTALLED 15"ABOVE FLOOR UNLESS ►-F-� �F-� E <br /> OTHERWISE NOTED OR REQUIRED. BREAK ROOM (KITCHEN): <br /> 6. ALL TELEPHONE AND COMPUTER WIRES SHALL BE PULLED BY TENANT CONTRACTOR UNLESS OTHERWISE 67 S,F. X 0.74 WATT=49.58 WATTAGE ALLOWED ��. <br /> LF-2: 24 W X 2 FIXTURES = 48 WATT USED *OKAY <br /> NOTED. ELECTRICAL CONTRACTOR SHALL PRQVIDE PULL WIRES AND BOXES AT EACH LOCATION. <br /> 7. CONTRACTOR MAY USE EXISTING LIGHT FIXTURES IF IN PROPER WORKING CONDITION AND CODE COMPLIANT. <br /> 8. ALL CORE DRILL LOCATIONS SHALL BE VERIFIED WITH DESIGNER PRIOR TO DRAWING.ALL UNUSED CORE <br /> DRILLS SHALL BE PLUGGED AND CAPPED AS REQUIRED TO MAINTAIN FLOOR FIRE RATING. <br /> 9. ELECTRICAL CONTRACTOR SHALL PROVIDE SEPARATE SWITCHING SYSTEM IN DAYLIGHT AREAS AS REQUIRED <br /> PER 2006 WASHINGTON STATE ENERGY CODE. <br /> NORTH <br /> � Reflected Ceilin Plan <br /> SCALE. 1/4 - 1 - 0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.