1707 SCENIC DR SNO CO PUD Geotech Report 2022-10-25
>
Address Records
>
SCENIC DR
>
1707
>
SNO CO PUD
>
Geotech Report
>
1707 SCENIC DR SNO CO PUD Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:07:07 PM
Creation date
1/6/2020 2:11:56 PM
Metadata
Fields
Template:
Address Document
Street Name
SCENIC DR
Street Number
1707
Tenant Name
SNO CO PUD
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FINISHED GRADE <br /> TEMP EROSION CONTROL BLANKET <br /> (CURLEX II OR SC150) <br /> ___\ <br /> HYDROSEED FINISHED SLOPE <br /> � � 2:1 SLOPE, MAX. <br /> � <br /> � EXISTING GRADE <br /> � <br /> � <br /> � SAND DRAINAGE BLANKET <br /> STRUCTURAL FILL � <br /> � <br /> � \ <br /> �EXISTING SOILS I \ <br /> 1 <br /> 6'MIN., <br /> BENCH IN STRUCTURAL FILL(TYP.) TO BE DETERMINED IN <br /> FIELD BY ENGINEER <br /> � — <br /> N � <br /> O� � <br /> i _ <br /> 1 <br /> O <br /> N KEY(3'DEEP x 6'WIDE,MIN.) <br /> N <br /> N <br /> o GENERAL NOTES <br /> o NOTE 1: STRUCTURAL FILL <br /> � FILL USED ON THE PROJECT SHOULD BE STRUCTURAL FILL MATERIAL.STRUCTURAL FILL SHOULD CONSIST OF PROPERLY MOISTURE <br /> = CONDITIONED AND COMPACTED ON-SITE FILL SOILS OR IMPORTED GRANULAR MATERIAL SUCH AS WSDOT GRAVEL BORROW THAT IS FREE <br /> ` � OF DEBRIS,ORGANIC CONTAMINANTS,OR ROCK FRAGMENTS LARGER THAN 4 INCHES. FILL SHOULD BE COMPACTED TO THE REQUIRED <br /> � PERCENTAGE OF THE MAXIMUM DRY DENSITY(MDD)PER AMERICAN SOCIETY FOR TESTING AND MATERIALS(ASTM)D 1557. <br /> > <br /> m <br /> W NOTE 2: REGRADED SLOPES <br /> "_- REGRADED SLOPES SHOULD BE NO STEEPER THAN 2H:1V.THE OUTER 8 FEET(HORIZONTAL DISTANCE)FROM FINISHED GRADE OF <br /> � REGRADED SLOPES SHOULD BE REMOVED AND REPLACED WITH STRUCTURAL FILL COMPACTED TO AT LEAST 90 PERCENT OF THE MDD <br /> F, PER ASTM D 1557. STRUCTURAL FILL SHOULD BE PLACED IN APPROX�MATELY 6 INCH LOOSE LIFTS PRIOR TO COMPACTION.REGRADED <br /> ¢ SLOPES SHOULD BE OVERBUILT BY AT LEAST 2 FEET AND THEN CUT BACK TO DESIGN GRADE PRIOR TO PLACING LANDSCAPING <br /> � MATERIALS.THE BOTTOM OF THE FILL ZONE SHOULD BE KEYED INTO THE EXISTING SOILS BY AT LEAST 3 FEET BELOW LOWESTADJACENT <br /> � GRADE.THE KEY SHOULD BE AT LEAST 6 FEET WIDE.THE STRUCTURAL FILL MATERIALS SHOULD BE BENCHED INTO THE TEMPORARY CUT <br /> 0 <br /> � SLOPE AT LEAST 5 FEET HORIZONTALLY AND NO MORE THAN 3 FEET VERTICALLY.THE SLOPES SHOULD BE TRACK WALKED PRIOR TO <br /> Q PLACING LANDSCAPE MATERIALS AND HYDROSEEDING. <br /> F <br /> � <br /> 3 NOTE 3: FILL SLOPES <br /> 0 <br /> �; NEW SLOPES SHOULD BE NO STEEPER THAN 2H:1V.IF EXISTING FILL IS WITHIN THE OUTER 8 FEET(HORIZONTAL DISTANCE)FROM <br /> o FINISHED GRADE OF FILL SLOPES,THEN EXISTING FILL SHOULD BE REMOVED TO A DISTANCE OF AT LEAST 8 FEET FROM THE SLOPE FACE <br /> a AND BE REPLACED WITH STRUCTURAL FILL COMPACTED TO AT LEAST 90 PERCENT OF THE MDD PER ASTM D 1557. STRUCTURAL FILL <br /> � <br /> w SHOULD BE PLACED IN APPROXIMATELY 6 INCH LOOSE LIFTS PRIOR TO COMPACTION. ALL FILL SLOPES SHOULD BE OVERBUILT BY AT <br /> � LEAST 2 FEETAND THEN CUT BACK TO DESIGN GR,4DE PRIOR TO PLACING LANDSCAPING MATERIALS.THE BOTTOM OF THE FILL ZONE <br /> w <br /> o SHOULD BE KEYED INTO THE EXISTING SOILS BY AT LEAST 3 FEET BELOW LOWESTADJACENT GRADE. THE KEY SHOULD BE AT LEAST 6 <br /> N FEET WIDE.THE STRUCTUR.4L FILL MATERIALS SHOULD BE BENCHED INTO THE TEMPORARY CUT SLOPE AT LEAST 5 FEET HORIZONTALLY <br /> � AND NO MORE THAN 3 FEET VERTICALLY. THE SLOPES SHOULD BE TRACK WALKED PRIOR TO PLACING LANDSCAPE MATERIALS AND <br /> � HYDROSEEDING. <br /> � <br /> N <br /> � NOTE 4: SAND DRAINAGE BLANKET <br /> N THE SAND DR,4INAGE BLANKET SHALL BE AT MINIMUM OF 12 INCHES THICK AND SHALL CONSIST OF SAND DRAINAGE BLANKET PER WSDOT <br /> � STANDARD SPECIFICATION 9-03.13(1). <br /> � <br /> � NOTE 5: MONITORING AND TESTING <br /> Q THE OWNER SHOULD EMPLOY THE GEOTECHNICAL ENGINEER TO OBSERVE EARTHWORK ACTIVITIES AND TO TEST STRUCTURAL FILL <br /> %� PLACED ON THE SITE.THE CONTRACTOR SHOULD FACILITATE OBSERVATIONS AND TESTING BY THE OWNER'S REPRESENTATIVES AS <br /> o NEEDED. <br /> � <br /> 0 <br /> � Slope Construction and Regrading <br /> 0 <br /> 0 <br /> � Beverly Park Substation <br /> W <br /> � Everett, Washington <br /> � <br /> 0 <br /> � �]EOENGINEER� Figure4 <br /> � <br /> � <br />