�ENERAL NOTES�
<br /> 1. ALL EXISTING BUILDING COLUMNS, EXTERIOR WALLS, EXTERIQR WINDOWS, AND ,
<br /> STRUCTURAL MEMBERS TO REMAIN, UON.
<br /> ����
<br /> 2. NEW RESTROOM(S) TO BE FULLY ACCESSIBLE PER THE PROVISIONS OF ANSI `"� ,
<br /> A117.1 SECTION 603 AS SUMMARIZED ON SHEET T1,2
<br /> T��r�� P�w�� ��i
<br /> KEY NUTES� O .
<br /> RESTROOM ACCESSORY MANUFACTURER: BOBRICK, CLASSIC SERIES, UON. .
<br /> STAINLESS STEEL WITH SATIN FlNISH a r C h I t@ C t S
<br /> 1. WATER CLOSEf. REFER TO 604/T1.2.
<br /> FLUSH CONTROLS SHALL BE ON OPEN SIDE OF THE WATER CI.OSET. 2505 Third Avenue
<br /> Suite 324
<br /> 2. SINK IN CQUNTER TOP. REFER TO 6Q6/T1.2. Seattie, WA 98121
<br /> 3. WALL HUNG SINK. REFER TQ 606fT1.2. 206.720.7001 phone
<br /> 206.720.2949 fax
<br /> 4. SURFACE MOUNTED MIRROR. 24X36. REFER TO 603/T1.2.
<br /> 5. SURFACE MOUNTED TOILEf PAPER DISPENSER MOUNTED BELOW GRAB BAR ��craftarchitects.com
<br /> MOUNTING ZONE. REFER TO 604.7/T1.2.
<br /> 6. SURFACE MOUNTED SANITARY NAPKIN DISPOSAL REFER TO 606/T1.2.
<br /> A B A5� C D 7. SURFACE MOUNTED TOILEf SEAT COVER DISPENSER. REFER TO 606/T1.2. �
<br /> 8. TOILET PARTITION, OVERHEAD BRACED. REFER TO 604/T1.2. �
<br /> � •
<br /> 4 '� 9. RECESSED PAPER TOWEL DISPENSER/WASTE RECEPTACLE, TYP. REFER TO O
<br /> '� � I'i j i;�I ��� � 606/T1.2.
<br /> �4 17 i �l,
<br /> �
<br /> ,
<br /> ,' ;
<br /> .�
<br /> I �
<br /> - -� - -- -- - -- I � - � 10. SURFACE MOUNTEO GRAB BARS PER ICC�ANSI A117.1 SECTIONS 604 AND m
<br /> � fi �;�; � I ; ii I � 609, SEE ALSO DETAIL 19�A5.1. PROVIDE BLOCKING AS REQUIRED. � �
<br /> ' 1 '� oc
<br /> ,o ,o � , � , , �� � � � �
<br /> 3 o II� �1 � �a ii i , 11. FLOOR DRAIN WITH TRAP PRIMER. 17' SQUARE SECTION OF FLOOR TO SLOPE � Q N
<br /> 7 � I ; II 15 TOWARD FLOOR DRAIN. �� �
<br /> 1 6 ' ;4i /� �
<br /> ; ; � �
<br /> ---------- ----- __ __�
<br /> �� ---- ---- - ��� --- - 12. WALL HUNG URINAL. REFER TO 805�T1.2. � Q
<br /> a Q
<br /> 13. MANEUVERING CLEARANCES / CLEAR FLOOR SPACE REQUIRED AT FIXTURE. W
<br /> REFER TO 305, 404, 604/T1.2., TYP. � � � �
<br /> 14. WAINSCOT, TYPICAL ALL (4) WALLS, UNO OR SHOWN WITHOUT WAINSCOT IN w T ~
<br /> : RTICAL OR BRUSHED ALUMINUM TOILET ROCJM ELEVATIONS ELEVATION. CC
<br /> IuIAX ALLOWABLE STRESSES VE /� � �
<br /> HORIZONTAL FORCE OF 250 POUNDS TRIM CAP �� ��4" = 1'-0" SEE T1.2 FOR MOUNTING HEIGHTS AND RELATIONSHIPS 15. WHITE INSULATION/COVER, SEE 606.6/T1.2. �
<br /> APPliEO AT ANY POINT ON THE GRAB BAR, � � I �
<br /> FASTENER MOUNTING DEVICE OR 16. SIGNAGE WITH BRAILIE, REFER TO 703/T1.2 W
<br /> SUPPORTING STRUCTURE. SINGLE OCCUPANCY: TRIMCO, 529, BLUE, MENS: TRIMCO, 527, BLUE, O Q �
<br /> WAINSCOT W/ MEfAL WOMENS: TRIMCO, 528, BLUE
<br /> PARTmON AS SCHEDULED TRIM AT SHEET EDGES � � ' W
<br /> z PER FINISH PLANS 17. ONE-PIECE, BARRIER-FREE, TRANSFER 7YPE SHOWER MODULE, 36AX36" WITH
<br /> � RECTANGULAR SHAPED FOLD DOWN TRANSFER SEAT WITH PHENOLIC SLATS W
<br /> ^ PER ICC/ANSI A117.1 SECTION 614.3 AND 610.4. BASIS OF DESIGN = � �
<br /> � ��2u �8 CDX-PNW, XS38BFAC OR EQUIVALENT. CONTROL AND HAND-SHOWER m
<br /> A � � B C D REQUIREMENTS PER ICC/ANSI At 17.1 SECTIONS 608.4 & 608.5. SURFACE /�
<br /> 1/4" DIA SHEE� MEfAL SCREWS TO �' MOUNTED GRAB BARS PER ICC/ANSI A117.1 SECTION 609, SEE ALSO DETAIL ,'`i
<br /> METAL BLDCKING�BACKING d- � � � ��� 14�A5.1. PROVIDE BLOCKING AS REQUIRED. WATER TEMPERATURE IN SHOWER
<br /> � 4 I ;-���`g�ls t �yt� NOT TO EXCEED 120 DEGREES PER ICC/ANSI A117.1 SECTION 608.8. �
<br /> 1 1/2" DIA GRAB BAR STRATEGIZE LOCATION OF IAMINATE ,� ' I /� = THRESHOLD HEIGHT NC�-��EX�EED 1/ ER ICC/ANSI A117.1 SECTIONS
<br /> (1 1�4" MIN TO 2" MAX OUTSIDE DIA) SEAMS TO MINIMIZE VISIBILITY. L j ' i � � i � � �s1/� � �J��� 608.6. (EXCEPTION � EXISTING FACILITI�°�N TRANSFER TYPE SHOWER
<br /> WHENEVER POSSIBLE. , � ;I '� �
<br /> LAYOUT SEAMS SYMMEfRICALLY » i , ; 14 _ � �� �r��`C � �P� , COMPARTMENTS WHE� �Rf�Vt�tQN �F A THRESHOLD 1/2" IN HEIGHT WOULD
<br /> - - - - ---- � �-
<br /> a - , � , a '� ��"� DISTURB THE STRUCTURAL REINFORCEMENT OF THE FLOOR SLAB, A CON3ULTANT
<br /> Q � _ �p �p ❑ � � , ' ��� I �� ,,S � � �� THRESHOLD� IuIAXIA�UM IN HEIGHT SHALL BE PERMITTED.) � �
<br /> � z � I, i
<br /> � i i I �� ` � ��
<br /> � COVE FL.00RING I �� � 3 � ,i�'i �� � � 18. PEDESTAL BEN N 20" DEEP X 42" MIN X 18" A�, FLOOR MOUNTED TO BE
<br /> i PROTRUDING ELEMENT RETURN UP WALL �$ I� � !
<br /> 7 15 �, ; ��� � yt.� �� FULLY ACCESSIBLE PER ICC/ANSI A117.1, SECTION 903.
<br /> � '`'�-_ 16 GA METAL STUD B�OCKING W/ (1) '�' 6 1 i �
<br /> � - --_______ __ �_-_ . .__.._____- _ ___ i I y�l, �
<br /> '`� � A35 CLIP TOP AND BOTTOM R� � ���,��?� � 19. RECESS SIZED TO ACCOMMODATE ADA BENCH. �
<br /> OR 3/4 PLYWOOD BACKING _ _ ��(�1/`� �y.� �
<br /> �� 20. ELECTRIC, 'INSTA-HOT'/POINT OF USE WATER HEATER, LOCATED UNDER SINK.
<br /> PLAM, FRP, OR CERAt�iC TILE OVER AT RESIUENT SHEET FLOOR � � EEMAX, SP4208 OR EQUNALENT, 4.1 KW, 208V, 1-PHSE, 41 F RISE � 0.5
<br /> WATER-RESISTANT GWB i �- �.�' GPM
<br /> OR PREFABRICATED SHOWER MODULE
<br /> � � � � � 21. NEW ACCESSIBLE (HI/LO) DRINKING FOUNTAIN AND CANE DETECTABLE FLOOR
<br /> GRAB BAR DETAIL SECTIC�N � WAINSCC�T TOILET RODM ELEVATIQNS MOUNTED APRON/GUARD. 48" H X 48" w MININUM FRP SURROUND OVER
<br /> 19 3" = 1'-0" �� 1" = 1'-0" � 1/4" = 1'-0" SEE T1.2 FOR MOUNTING HEIGHTS AND RElATIONSHIPS Wq�R RESISTANT GWB, CENTERED BEHIND FOUNTAIN. (NOT REQUIRED AT
<br /> RECESSED LOCATION). ��52 REGlST�RED
<br /> ARCHIfiE�'� �
<br /> 22. INSTALL FILM ON EXISTING WINDOW TO OBSCURE PARTI110N BEYOND.
<br /> KA YN Nl CRb4�FT
<br /> sTa?E F wasa�+ �x`
<br /> ��''���
<br /> .� � - 608.2.1 Transfer-type Shower Compartments.
<br /> Submittals/Revisions:
<br /> ��£ � Transfer-type shower compartments shall comply
<br /> ,...,:,,� fr x�,����:�.,,.
<br /> with Section 608.2.1. O��ZO��8 FOR PERMIT
<br /> � . O � `�' _ 10 10 �t 36
<br /> � = � � �41tEfi -r � ,.FTM,
<br /> �' � ,; � 915
<br /> �� � � i 6 r�� � °,
<br /> � ;� g 3 ��,� � R00�� 5 � bac�all
<br /> � i 1 11 A s,t i
<br /> <a
<br /> � � TOILET � �- - 13��� �� ��� �� '� � �
<br /> ROOM � __. ,� A5.1 � -- 3 seat �n
<br /> �05 �; -- - 18 �'`� wall � �` �walltrol � rn
<br /> �� :s.r �.
<br /> �- , �
<br /> r -
<br /> .'. . � 6 � _----� � -------- --
<br /> � � � 19 �i - i �
<br /> a�r �; � � �� �- i i
<br /> 3 , e� ,�: .w -,.. � � � �;r� i' i c
<br /> ��
<br /> ,
<br /> � � j � �
<br /> _ ,. ; �
<br /> )
<br /> � �
<br /> N � �: 21 � (,�j �- � O ) I cp �
<br /> � � �= 5 go a , , M
<br /> Q �, , �° ,
<br /> � �. . _ _�f, .. ... ,�: i
<br /> , i � �
<br /> W
<br /> � � i _�
<br /> o �T-
<br /> 3
<br /> � �� x � 19 �� -- ----
<br /> W �� » � 48�On Sheet Title: INTERIOR ELEVATIONS
<br /> '" 18� �� p�
<br /> ��
<br /> Q TOIL�T 104 , '
<br /> 6 � Note: inside finished dimensions measured
<br /> � RooM � & DEfAILS
<br /> z 1.04 i t3� ' 3 � at the center points of opposing sides
<br /> ° ` � - � FIG.608.2.1 Date: 07/11/18
<br /> Q � �$ I i
<br /> > �� � ���� � � TRANSFER-TYPE SHOWER
<br /> W � � ' g �pM 11 ,5 � COMPAFi7'MENi'SIZE�46dD CLEARANCE
<br /> �; ' 104
<br /> 16 3 Design:
<br /> Z • 56
<br /> o � � �� � ° Drawn:
<br /> W � 3 � 10 ' 10
<br /> � :; � ���
<br /> � �� �� �:�a
<br /> � 3 ��ri � � n� � � r -'� `�.���`
<br /> Z Project Na: 18-Q76.05
<br /> W
<br /> � 7'-3" 3 Approved: KCR
<br /> Q�
<br /> � �
<br /> r
<br /> 0
<br /> E N ENLARGED RCP TOILET ROOMS N ENLARGED TC�ILET RC�OMS Building No:
<br /> a � ��4„ _ �'-0" 1 ��4„ _ �'-0"
<br /> 0
<br /> �
<br /> � Sheet No:
<br /> .
<br /> �
<br /> �
<br /> � COPYRIGHT CRAFT ARCHITECTS 2018
<br />
|