My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3420 BELL AVE 2018 Plans 2022-11-23
>
Address Records
>
BELL AVE
>
3420
>
Plans
>
3420 BELL AVE 2018 Plans 2022-11-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2022 3:27:15 PM
Creation date
1/8/2020 9:53:51 AM
Metadata
Fields
Template:
Address Document
Street Name
BELL AVE
Street Number
3420
Permit
C1904-016
Year
2018
Notes
CONVERT FINISHED BASEMENT INTO ADU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> NOTE: THIS DRAWING f�EPKESENTS CURRENT KNOWN SITE CONDITIONS. ACTUAL SITE CONDITIONS AT ThE TIME OF INSTALLATION MAY VARY AND/OR .� � <br /> ALTER FINAL DIM�NSIONS. DO NOT SCALE Df�AWiNGS FOI� DIMEN510NS. ALL DIMENSIONS CIT�D ON DI�AWINGS ARE TO BE USED IN Th� FIELD. � o <br /> Tt1ESE PLANS AI�E Tf1E 50LE PI�OPERTY OF NEIL KELLY COMPANY AND AIZE FOIZ OUR U5E ONLY. Tt1EY AIZE NOT TO BE I�EPI�ODUCF_D OR OTIIEIZWISE � o � <br /> USED FOR BIDDING, CONSTRUCTION OR PERMITTING PARTIALLY OI� IN WhOLE BY ANY OThER PARTIES WITNOUT PERMISSION FROM Tf1E NEIL KELLY Q � � <br /> , COMPANY. TIL� DESIGN MAY VARY DUE TO HEIGIIT, WIDTH � ThICKNE55. Tt1E5E PLANS ARE DESIGNED TO MEET TNE 20 I 5 EDITION OF ThE EVERETT �+ � � <br /> RESIDENTIAL CODE AND TNE 20 I 5 EV�RETT BUILDING CODE AND ANY OThER CODES, AMENDMENTS, AND SUPPL�MENTS CURRENTLY IN �FFECT. N � N � <br /> � � <br /> � � o <br /> "� � ".' `', <br /> 0 <br /> � � <br /> � � `nH <br /> � � � � <br /> • � � ``'wz <br /> � ° � <br /> 48'-I" v � O � <br /> 10'-8" ' 9'-8" ' 10'-�" ' 17'-3" � � � <br /> EL�CT�ICAL L�G�ND •� °� � <br /> All new and reworked outlets in kitchen and bathrooms to � ° � ° I � ° � �� � � � <br /> 4-I I � 4-9 5-8 4-10 <br /> be on GFCI � � <br /> All new and reworked outlets in bedroonis to be on AFCI � <br /> (E) 59 I 9 XO (E) 59 I 9 XO (E) 5� I y XO <br /> -Ef}- SINGLE POLE SWITCH <br /> `�- 3-WAY SWITCH — anseaoaRo — — easesonao <br /> HEATER HEATER �VERIFY':EXISTING <br /> N N I � �GD /DWI N 5/8"7YPEXGWBATCEILINGONLY ISSUES & REVISIONS <br /> MICRO � O � N � L.C) IF LNING SPACE ABOVE. I/2"GWB � � <br /> � I I / \ I I _<. � M W.AT WALL�i DISWIl: Ofj Z I 2O I fS-U <br /> 110v DUPLEX OUTLET �--\�_— i , (� INSUIJa�E ALL WAKM WALL�AND Rev15eCI: <br /> r— = A CCILING. <br /> � 220v outlet STORAGE I ' � � >= rr+eR J <br /> —-I CA�ETTOE KICK Revised: <br /> CN:7�I-I��J�� HEATERSIZETBD N � �� Revise�: <br /> RECESSED LIGHT FIXTURE � NEW WALL <br /> I BY ELECTRICIAN ReViSef]: <br /> PENDANTLIGHT � � " KITCNEN � LIVING ROOM / Rcviscd: <br /> (E) 4x I O <br /> � � Cr1:7'-I/2" a" - � CI1: 7'-�i��" — — — Revised: <br /> SURFACE MOUNT LIGHT ��e W c� � � / Revised: <br /> � HOOD DUCTLESS RAN6� A �I � N N Reviszd: <br /> �- WALL MOUNT LIGHT FIXTURE Y100U PER SEC. _ �' <br /> {��� �" M I 503.3 3 I I <br /> � APPLIANCE CIRCUIT � I N / Revised: <br /> 1 � /'v" NEW WALL / Revised: <br /> GD SWITCH GARBAGE DISPOSAL ��,�� L���� l " i N `" � _ "�� GARAGE II r <br /> �j� i � _ � --�� r�r� � C.t1.6- I 0-5/8 <br /> N NEW(ORNOLABEL) ��� ��ry� —�---�--- �< „ � <br /> �, ��\IY <br /> E EXISTING � � : rH�� � � <br /> � RELOCATE 8 �� N I N N ��� � � _ _ (E) 4xI0_ <br /> 2 2� , 26 <br /> � SMOKE DETECTOR � _�--- — _ <br /> co CODetector �_ NDINING I `` N _� —� <br /> �-- / 2� \ <br /> EXHAUST FAN ONLY I O'-8" `-J�r6° S 4�-7°j� ,� �}, J�-3° ��'� ° � \ / <br /> HALL � s <br /> �— N c� �� ' 2 I a'SOLID CORE � <br /> �i � �- Ct1:7'-3/�F° �� 000R(zo MiNure� <br /> � f1ALL I / SELF CLOSING <br /> 0 <br /> 9 I � CI1:7'-I I/8° � 2'� (E) 4x I 0 <br /> N � Q I ��_ � � — — - - <br /> � � r , �IREPLACE MUDf�00M <br /> � CONSTRUC�fION LEC�END W i � / cN.i�-o�� �E���: ��sT�N� � <br /> � 5/8'Tl'PE X GNlB f�i CEILING UNCr' <br /> \ IF LIVINCG SPF�CE F�BOVE. I/2 G�NB � <br /> \ MIDI.F\T WALLS <br /> ,��� ��,���''i�'?����.;�� PANTRY � o� I I I \ CEILI GrE ALL WARJvt WALLS AND <br /> '�a' I <br /> NEW WALLS / INa \ L — —_—_----J � <br /> r...............� aw / � Q <br /> � � � �����J DEMO WALLS Im= LY_, <br /> � BATt1R OM � \ \�3 � � <br /> �. ��- �_ �� hA L � O <br /> I I EXISTWG BEAMS � -y2�c�F8 RC PERS C�� I 26 Ch:�' I" I \ \ 28 <br /> � � 0 — - � �� �M�f 505�43• 1�_ t1�7 �L • • <br /> CEILING HEIGHT CHANGE iNT��"unENT SYSrEM f�/�7�t/ l r,-s � �E� 7s 80��p � � <br /> tL <br /> CONTROL VTO I 20 CFM � �r- I�-�j"SOLID CORE � <br /> w � a DOOR(20 MINUTE) O -- � <br /> (E) OT � F� SELF CLOSING W— � � � <br /> N1A ER -� � � � <br /> TAN MECIIANICAL VENTIIATION: � N <br /> � EXTENTS OF FRAMING � � !1\ � Q O <br /> EXISTINGSPAN&DIRECTIONOF / � � WIIERE LOCAL OR WI10LE tiOIJSE MECYIANICAL \LJ � <br /> � � O(� � O� C> � <br /> FRAMWG2x10@12"o.c. W VENTILATION IS PKOVIDED, TF1E EQUIPMENT <br /> J w 511ALL BE DESIGNED IN ACCORDANCE OF TI1E <br /> �Q I � I ' O 20I 8 IRC�WA, STATE AMENDMENTS PER SEC. � � Q� � I '' � <br /> `�'� W I {� �m M I 505 EXCEPTION: TF1E Wf10LE f10USE � � � z � <br /> "' ' MECIIANICAL VENTILATION SYSTENI IS PERMITTED � <br /> � c=n I `� TO OPERATE INTERMITTENTLY WIIERE TI1E � <br /> SYSTEM 11AS CONTROLS TY1AT ENABLE � � O � � <br /> 26 I 6EDROOM w OPERATION FOF�NOT LESS TI1AN 25%OF EACFi - —� N -� �-- � <br /> � CI1:7'-I/2" 4 1 1 0 U R S E G M E NT A N D V E N T I L A T I O N R A T E Q� -G-� _j z <br /> ---- I PRESC�IBED. -6 � Q� � Q <br /> `_� EXf1AUST DISCt1ARGE: O `, f � (J� � <br /> PLY SHEAR PANEL,N!H=RE STORAGE <br /> OCCUREs, PER EXISTWG CH:7,_�„ � i DOMESTIC COOKING EXf1AUST EQUIPMENT � W � � <br /> 2x STUDS � 16" O.C. <br /> DRI�L & =PDXY 3 8 � x 6-1 2 511ALL COMPLY N/ITFi TF1E REQUIREMENTS OF TF1E � O U <br /> � � �� � �� O � 20I 8 I�C�WA, STATE AMENDMENTS SEC. <br /> 4"min. EMBED UX �/ CLOSET M I 503.3 EXCEPTION: Wf1ERE INSTALLED IN U W <br /> EXISTING CONC. SLAB NlEDGF ANCHOR BOLTS _ <br /> ' @ 3" FROM EA. END OF �, ACGORDANGE WITI1 MANUFACTURERS .� <br /> NEN! 'J�JALL `A!/ 2x � INSTRUCTIONS, AND Wf1E�E MECIIANICAL OR z <br /> P roF s�LL Pi_aT_ NATURAL VENTILATION IS OTIIERWISE PROVIDED, O <br /> w LISTED AND IABELED DUCTLESS RANGE t100DS � n / <br /> �'�� � � �' :°-,�� • SFIALL NOT P�E REQUIRED TO DISCIIARGE TO TF1E 1�- <br /> • • . .� .:a ; .• s :r�.r . �a OUTDOORS. � Q_ <br /> .d <br /> . . . -.. '� .e� .. .e - • -- JII SMOKE ALARMS: ' Q <br /> � BASEBOARDJI <br /> -� � HEATER SMOKE AIARMS 5F1ALL P�E INSTALLED PER 20 I 8 <br /> �a.•4 ' w ' � IRC �WA, STATE AMENDMENTS SEC. R3 I 4.3 <br /> �I ,.• • • ° ' IN EACFi SLEEPING ROOM. OUTSIDE EACh1 <br /> EXISTING CONC. FTG PI�OPOS ED SEPARATE SLEEPING AREA IN TI1E IMMEDIATE <br /> VICINITY OF TI1E BEDROOM. SMOKE ALARMS PAGE <br /> SIIALL BE INSTALLED NOT LESS TI1AN 3 FEET <br /> I N TERI OR WALL D ETAI L 110RIZONTALLY FROM TI1E DOOR OR OPENING 3 <br /> A KI TC N E N / D I N I N G TF1AT CONTAINS A BATIITUB OR 5110WER. <br /> 3 sca�E: N.r.s. PROVIDE APPROVED CARBON MONOXIDE <br /> � �LO O I� P LA N ALARMS PER 20 I 8 IRC�WA. STATE <br /> AMENDMENTS SEC. R31 5.I <br /> CARBON MONOXIDE ALARMS IN DWELLING UNITS <br /> SCALE: I/4" = I'_O" SIIALL BE INSTALLED OUTSIDE OP EACI1 PROPOSED <br /> ALL WOOD IN CONTACT WITI-1 CONCRETE SEPARATE SLEEPING AREA IN Tt1E IMMEDIATE <br /> St1ALL BE PRESSURE TI:EATED. DIMENSIONS IN FEET VICINITY OF Tt1E BEDROOMS. BASEMENT <br /> COMBINATION CAKBON MONOXIDE AND SMOKE FLOOR PLAN <br /> SOLIU BLOCKING UNDE�ALL BEA�?ING WALLS. <br /> ALARMS SFIALL BE PERMITTED TO BE USED IN <br /> INTERIOR WALLS TO BE Pf�AMED WITF1 2X4 HEM-FIR No.2 � �� LIEU OF CARBON MONOXIDE ALARIv1S. <br /> S'TUDS @ I 6" O.C. AT eiEARINC' WALLS, 24"O.C. � �j'�� <br /> MINIMUM AT NON BEAR.ING WALLS. <br /> APRIL 18,2019 <br /> NKClBx24v1-SP Mny2012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.