My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5001 COLBY AVE 2017 Plans 2022-11-07
>
Address Records
>
COLBY AVE
>
5001
>
Plans
>
5001 COLBY AVE 2017 Plans 2022-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2022 1:55:48 PM
Creation date
1/8/2020 10:36:29 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
5001
Permit
C1711-007
Year
2017
Notes
NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following Washington State Energy Code information is required: � <br /> V <br /> a. Post Energy Code Compliance Certificate within 3 ft. of electrical panel (these are available p � <br /> at www.energy.wsu.edu/code) V � � <br /> b. Provide door blower test affidavit by final building inspection � 4 � <br /> , c. Provide (1) pro grammable thermostat � � Z <br /> d. Provide duct sealing affidavit by final inspection ��,�� � � <br /> e. A minimum of 75% of all interior lighting shall be high-�f�reie�Ey � ��t�t5 Q <br /> f. All required insulation and glazing values � � a <br /> g. Building framing cavities shall not be used for ducts or plenums. Installation of ducts in � <br /> exterior walls, floors, or ceilings shall not displace required envelope insulation. � � � <br /> N � � <br /> � � � <br /> � � <br /> � j41'-6" M <br /> W <br /> 11'-4 1/2" 8'-7 1/2" 20' 1'-6° <br /> � 3,5„ 5, 2'-11 1/2" 3�-2" 2' 3'-5 1/2" 2'-7" 4' 5'-9° 5' 2'-8" ��j��'� Z <br /> � <br /> �SW1 �'„�� <br /> SW1 2 SW1 tt t� � <br /> 5040LS 030SH �{ <br /> 1� � <br /> �A\\ \\\ � A � \\\\\\ \\�� � V ` � <br /> � j EGRESS WINDOW � FaN GLASSY SW1 � 4036LS SW� � � 504oLS SW� �5��`� � <br /> � P E R R-310.1 _ N — ,�\\ \V` � A \\\ \\ \\\� \\\\\\\V�� � <br /> � - - <br /> � MASTER BEDROOM �, 5o cFnn v-ro �� � �_� � �o � � � <br /> . � � � oa ;�s� � � o <br /> , � � � <br /> N ; .� � <br /> a �N � R311.3.2 MIN LANDING 36 X 36 _ <br /> 100 CFM WITH 7 3/4" MAX RISE �J <br /> i WHOLE HOUSE FAN PER � � FAN FAN VTO TO TOP OFTHRESHOLD � �, o, �, � /� /y�,�'� r��� � <br /> M1507.3 W/24 HR TIMER � 2020 SKYLIGHT _ � a, �� <br /> � N ��� �-� � <br /> i R-4 DUCT INSULATION, AND � D I N I N G � � Q <br /> � � � '�S�SONE RATING. VT(�? � �FAN � ISLAND �� � � �� ��CK � �_'� � <br /> , �s �� , �� w O <br /> � 6'-41l2" rU'�' � - <br /> �� 3'-6"��4'-8" WHOLE HOUSE FAN: �ABEL SHALL BE � � � � <br /> % 2468 � AFFIXED TO THE CONTROL THAT READS: Q� -� W = <br /> i � "WHOLE HOUSE VENTILATION (SEE � � <br /> � 2668 2468 LINEN N � -0PERATING WSTRUCTIONS)" w Q <br /> � � SMOKE ALARM 4068 I ( V <br /> � � j PER R314 SD CARBON MONOXIDE �z _ � SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN J <br /> N �, � � . ' _ c o ALARM PER R315.1 W U U "' N 3 FT HORIZONTALLY FROM THE DOOR OR OPENING OF A �J <br /> c�i� i � R807.1 -22X30 ATTIC � -' Q � BATHROOM THAT CONTAINS A TUB OR SHOWER. R314 � <br /> � � ACCESS. INSULATE m �� cn <br /> � AND WEATHERSTRIP. � W � IONIZATION SMOKE ALARMS: W <br /> % 2468 N� � SHALL NOT BE INSTALLED LESS THAN 20 FT <br /> i I �v � HORIZONTALLY FROM A PERMANENTLY INSTALLED � <br /> � j 2668 2668 � � <br /> N 5068 5oss N DN I t�'1 GREAT ROOM � COOKING APPLIANCE. �,z <br /> � +) �� IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING W <br /> � J\ SWITCH SHALL NOT BE INSTALLED LESS THAN 10 FT �' <br /> � 1 1 Q v� HORIZONTALLY FROM A PERMANENTLY INSTALLED Q <br /> 3'-6" 3'-6" 6'-2" 3'-8° 3'-6" � N <br /> i � � ALL EXT WINDOW AND DOOR �, - <br /> o COOKING APPLIANCE. <br /> i �_ ��, I� I � HDRS TO BE 4X8 DF#2 U.N.O. � `° Li <br /> � j N � _ � �' PHOTO ELECTRIC SMOKE ALARMS: a <br /> � � _ �a SHALL NOT BE INSTALLED LESS THAN 6 FT <br /> � j BEDROOM 2 0 � � � �5� HORIZONTALLY FROM A PERMANENTLY WSTALLED �j" <br /> � BEDROOM 3 �' �� � COOKING APPLIANCE. W <br /> � � � SAFETY i �-, - � � <br /> j GLASS 3 1/8 X 9 24F GLB � �.�C�� � � � � � O <br /> \ tV <br /> � <br /> j EGRESS WINDOW EGRESS WINDOW ��� �� � ��� � � � <br /> j PER R-310.1 PER R-310.1 N 3068 2050FX SW� 7050FX � <br /> / � SW1 <br /> �� \ \ � .A\\\\ ,A\ \ � A �A � � Z <br /> �� � 404oLS � 4040LS �W� pE�',K PORCH$EAMS � � <br /> SW1 SW1 TO BE 4X8 DF#2 J � <br /> 0 nniN 4x4 Pos-r UPPER FLOOR PLAN C7 a <br /> ' 3'-2" 4' 2'-8 1!2" 2'-11 1/2" 4� 3,_2,� � 6'-8 1/2" � 3'-0 1/2" 7' 3'-3" SCALE 1/4"=1 FT � ' � <br /> 9'-101/2" 10'-1 1/2" 6'-81/2° I 13'-31/2" 1'-6" ��������' ��v��� W � <br /> i fi�ll�9��lUIN�b�S 6EEN REVIEWED FOR W <br /> , „I � �b���F�1��Q�LIEVANT DOCOUMENI'S. � � <br /> 41-6 ( i ��l�a;� ��`C� DA7E l��"Z21��' � LL <br /> � UP �� � ���l��'�� �Y m a <br /> � * j �����"��1�1`.�`g�v�i e5�n ups�� <br /> I �" ,v�r��n�s�, <br /> - �p��4���.�Ma�nrrt av r r��n. <br /> DATE: <br /> ����� �,,�- 11/17/2017 <br /> � �'i1J� .,� �„ � �� ���i <br /> ��~7 �� (i l:� � � �' � EHD JOB: <br /> li�"- <br /> 2109 <br /> �;���T �� �������� SHEET: <br /> �`���':��,�'�I��� �'�� ����v��`�' <br /> 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.