Laserfiche WebLink
W <br /> GENERALNOTES � <br /> ROOFING MATERIAL TO BE � � <br /> ALL CONSTRUCTION SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL 2X8 PT LEDGER AT WALL WITH 1/2 X 4" MID ROOF"UNDER SHINGLE"VENTING TO COMPOSITION OVER 30LB FELT o � <br /> CODE,2015 INTERNATIONAL BUILDING CODE,AND THE 2015 WASHINGTON STATE STAGGERED LAG BOLTS AT 18"OC INTO RIM PROVIDE LOWER ATTIC VENTILATION. 7/16"OSB ROOF � � <br /> ENERGY CODE. JOIST. LAG BOLTS SHALL BE 2" FROM TOP OR 4X4 SUPPORT POST SHEATHING.8D AT 6" � O <br /> RIM JOIST <br /> BOTrOM AND 2"TO 5"FROM ENDS OF LEDGER \ OC AT EDGES AND � U � <br /> R-408.2 (WAC 51-51)UNDERFLOOR VENTILATION REQUIRES 1 SQ FT OF NET FREE � � SOLID TIGHT FITTING \ 12"OC AT FIELD � (/� � <br /> CROSS VENTILATION FOR EACH 300 SQ FT OF UNDERFLOOR AREA COVERED. SIDWG �� BLOCKING(NO VENTS) ; INSULATION <br /> H1 ROOF TO TOP PER ENERGY � � <br /> R-408.4 UNDERFLOOR ACCESS: MINIMUM 18"X 24"CLEAR ACCESS THROUGH METAL FLASHING � \ DTT2 CONNECTOR �� PLATE CONNECTION� �INFORMATION � � � <br /> FLOOR, MIN 16"X 24"THROUGH EXT WALL � �I�,/ �� AT EACH TRUSS PAGE � �• <br /> L � � <br /> a a T VENTED 2X ��,�/,� � ^� (� <br /> R-317.1 WOOD FLOOR JOIST CLOSER THAN 18"AND WOOD GIRDERS CLOSER THAN BLOCKING � � <br /> 12"FROM THE EXPOSED GROUND MUST BE PRESSURE TREATED. �°� � o � a°� a �°� � � °� - INSULATION PER ENERGY � <br /> ° � ° � °�° ° ° � �NFORMATION PAGE / ' �INSULATION BAFFLE WITH 1" � � <br /> FASTENERS INTO OR IN CONTACT WITH PRESSURE TREATED OR FIRE RETARDANT LUS28o MIN AIR SPACE TO EXTEND � <br /> RIM JOIST HEADER PER PLAN TO 12"VERTICALLY ABOVE � � � <br /> TREATED WOOD SHALL BE OF HOT-DIPPED GALVANIZED STEEL,STAWLESS STEEL, MSTC28 OR(2)HTT4 ���'6�� � INSULATION � � <br /> ' SILICON BRONZE OR COPPER. EXCEPTION: 1/2 INCH DIAMETER OR GREATER STEEL AT TWO LOCATIONS TO ��� SHEATHWG PER <br /> BOLTS. CONNECT FLOOR 2X8 DECK JOISTS SW SCHEDULE � � <br /> SOLID BLOCKING NOTE: GABLE ENDS THAT ARE DIRECTLY UP AGAINST <br /> DIAPHRAGM TO DECK JOISTS 5 FT SETBACK SHALL HAVE NO GABLE VENTS <br /> R-806.2 ATi�IC VENTILATION REQUIRES NET FREE CROSS VENTILATION 1/150 OF 2X6 WALL FRAMING AT 16"OC npy <br /> ATTIC AREA. OR 1/300 IF 40-50 PERCENT IS UPPER VENTILATION.VENTED BLOCKING <br /> �d <br /> AND GABLE END VENTING IS NOTALLOWED WHEN THE EXTERIOR WALL IS 5 FT OR ROOF OVERHANG INTRUDI NG INTO TYPICAL ROOF 70 WALL <br /> LESS FROM THE PROPERTY LINE OR WHEN THE EAVE OR OVERHANG IS LESS THAN D4 DECK CONNECTION TO WALL D3 4X4 DECK RAILING POST SUF'PORT �2 D� <br /> 5 FT FROM THE PROPERTY LINE.WHEN APPLICABLE SEE D2 5 FT PROPERTY LINE SETBACK AND HEADER SECTION <br /> R-807 ATTIC ACCESS REQUIRES 22"X 30"MIN CLEAR OPENING IN A READILY <br /> ACCESSIBLE AREA.30"MW HEADROOM, INSULATE AND WEATHERSTRIP <br /> ROOF TO WALL 1'-6" 1 HOUR FIRE PROTECTION <br /> R-310 EGRESS OPENINGS SHALL HAVE A SIL�HEIGHT OF NOT MORE THAN 44" 8D NAILS AT 6"OC PERIMETER PROVIDED BY 5/8"GWB AT BATT INSULATION PER <br /> ABOVE THE FLOOR WITH A MIN OF 5.7 SQUARE FEET,A MIN WIDTH OF 20"AND A MIN NAILING TO LEDGER FLASHING BATT INSULATION PER <br /> ALL SIDES ENERGY INFORMATION PAGE ENERGY INFORMATION PAGE <br /> HEIGHT OF 24". PARALLEL OR <br /> - TIGHT FIT SOLID PERPENDICULAR NAILWG TO SOLID BLOCKING. � <br /> R-314.3 INTERCONNECTED SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING BLOCKING \ � ROOF FRAMING 18" MAXIMUM ENCROACHMENT INTO SPACING PER PERIMETER <br /> ROOM, IN THE IMMEDIATE VICINITY OUTSIDE EACH SLEEPING AREA AND ON EACH \ � _�� __ 5'SETBACK.THIS WIDTH WCLUDES NAILWG OF FLOOR DIAPHRAGM <br /> STORY. y�i ���� TRIM, FINISHES, EAVESAND BASEPLATE NAILWG <br /> BASEPLATE NAILWG � �� OVERHANGS. 1 HOUR MINIMUM FIRE PER SW SCHEDULE i'���,' � <br /> SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY PER SW SCHEDULE ��\ \ RESISTIVE CONSTRUCTION. � /� <br /> FROM THE DOOR OR OPENING OF A BATHROOM THAT CONTAINS A TUB OR \ RIM JOIST 3/4"FLOOR PLYWOOD 3/4" FL'OOR PLYWOOD <br /> SHOWER. R314 � 2X LEDGER, BLOCK, � / y, �� ` � � <br /> SHEARWALL PER RqFTER OR TRUSS WITH RIM JOIST ❑ <br /> IONIZATION SMOKE ALARMS:SHALL NOT BE INSTALLED LESS THAN 20 FT SCHEDULE (2) 16D TO EACH STUD FLOOR JOIST �� FLOOR JOIST <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE PER PLAN PER PLAN � � <br /> IONIZATION SMOKE ALARMS WITH AN ALARM-SILENCING SWITCN SHALL NOT BE FLOOR JOIST �PERIMETER NAILING �� � Q�/ <br /> INSTALLED LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED PER SW SCHEDULE BATT INSULATION PER FLOOR TO TOP WALL FRAMING � 6L � <br /> BASEPLATE NAILING � FLOOR TO TOP <br /> COOKWG APPLIANCE ENERGY INFORMATION PAGE PER SW SCHEDULE PLATE CONNECTION PLATE CONNECTION W <br /> I PER SW SCHEDULE PER SW SCHEDULE � <br /> ' PHOTO ELECTRIC SMOKE ALARMS:SHALL NOT BE INSTALLED LESS THAN 6 FT TYPICAL PARALLEL OR � <br /> HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKINGAPPLIANCE. PERPENDICULAR LOWER �$�� CANTILEVER INTRUDING INTO WALL FRAMING TYPICAL UPPER FLOOR W <br /> R315.1 CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE EACH SLEEPING CA� ROOF TO WALL CONNECTION C3 5 FT PROPERTY LINE SETBACK CZ CANTILEVER UPPER FLOOR C� I 1 <br /> AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS. .JOIST SECTION � <br /> J <br /> R-308.4 SAFETY GLAZING IS REQUIRED AT ENCLOSURES FOR TUBS AND SHOWERS � <br /> AND WHEN PLACED WITHIN 24"ARC OF EITHER VERTICAL EDGE OF DOOR AND 12"MIN REQUIRED 3/4"SUBFLOOR NAILED WITH 8D AT 6" BASEPLATE NAILING s/1 <br /> LAZING IS LESS THAN 60"ABOVE FLOOR. BETWEEN BEAM AND OC AT EDGES AND 12"OC AT FIELD PER SW SCHEDULE <br /> NAILING TO SOLID BLOCKING. BASEPLATE NAILING r� <br /> GROUND. 18"MIN SPACING PER PERIMETER WALL FRAMING PER SW SCHEDULE W <br /> M-1503 RANGE HOOD SHALL DISCHARGE TO THE OUTDOORS THROUGH A SINGLE REQUIRED BETWEEN BATT INSULATION \ NAILING OF FLOOR DIAPHRAGM �� WALL FRAMING � <br /> WALL DUCT THE DUCT SERVING THE HOOD SHALL HAVE A SMOOTH INTERIOR JOISTS AND GROUND. � <br /> SURFACE, SHALL BE AIR TIGHT AND SHALL BE EQUIPPED WITH A BACKDRAFT PER ENERGY , 3l4" FLOOR PLYWOOD ��. BATT INSULATION �� <br /> DAMPER. SOLID BLOCKWG OVER BEAM INFORMATION PAGE PER ENERGY \ 3/4"FLOOR PLYWOOD �■L <br /> � / 4"CONCRETE SLAB FLOOR INFORMATION PAGE � � <br /> FLOOR JOIST PRESSURE TREATED FLOOR JOIST a. <br /> • R319.1 BUILDINGS SHALL HAVE APPROVED ADDRESS NUMBERS. MIN SIZE 4 IN WITH FLOOR JOIST I � / PER PLAN SILL PLATE \\ RIM JOIST � PER PLAN � <br /> � <br /> 1/2 IN STROKE AND CONTRASTING BACKGROUND AND VISIBLE FROM STREET. PER PLAN � <br /> RIM JOIST ' r � � -� , �, n/ <br /> DESIGN CRITERIA PT POST OR 90LB PROVIDE A23 AND AC4 � v� e � o . PRESSURE TREATED o. \� Id� <br /> I o �` FLOOR TO TOP � " SILL PLATE � <br /> FELT AT BOTTOM OR APPROVED • I I1=1II I I I-'=1 FLOOR TO TOP a <br /> ROOF LIVE LOAD 25-ROOF DEAD LOAD 15 � - POSITIVE CONNECTION BATT INSULATION �?� ' PLATE CONNECTION ,�rrr-m <br />