My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5001 COLBY AVE 2017 Plans 2022-11-07
>
Address Records
>
COLBY AVE
>
5001
>
Plans
>
5001 COLBY AVE 2017 Plans 2022-11-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2022 1:55:48 PM
Creation date
1/8/2020 10:36:29 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
5001
Permit
C1711-007
Year
2017
Notes
NEW SFR
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: 2015 Washington State Windows and Doors � <br /> . � <br /> Prepared by: Dennis Smiley/ Emerald Home Design Quantity width �t width �n Height Ft Height �n R406 ADDITIONAL ENERGY EFFICIENCY REQUIREMENTS O � <br /> Windows 1 7 0 4 0 � <br /> Builder-Glacier View Properties 4 5 0 4 0 U � <br /> Plan Name- 1470 2 4 0 4 o Medium Dwelling Unit (1500-5000 SF) requires 3.5 point from table R406 � � � <br /> 1 2 0 5 0 <br /> Design Temp- 21 /70 deg- 21 49 1 5 6 3 o This project selects the following: � � � <br /> 1 7 0 5 0 � (�Zf' Q <br /> Conditioned Floor Area 1,470 1 4 0 3 6 '� <br /> Average Ceiling Ht s.49 1 2 0 3 o EFFICIENT BUILDING ENVELOPE 1a: � � �. <br /> Conditioned Volume 12476 0 0 0 0 0 <br /> Prescriptive compliance is based on Table R402.1.1 with the following modifications: � � t/j <br /> 0 0 0 0 o Vertical fenestration U = 0.28 � � � <br /> ' Component U-Factor Area UA 0 0 0 0 o Floor R-38 � � � <br /> Glazing and Doors o.2so 3za 91.7 0 0 0 0 o Slab on grade R-10 perimeter and under entire slab � � � <br /> Below grade slab R-10 perimeter and under entire slab .,J <br /> skyi�gnts o.soo 4 Z.o 0 0 0 0 0 or � ''' <br /> Attic Area - R-49 0.026 1,026 26J 0 0 0 0 0 � <br /> Compliance based on Section R402.1.4: Reduce the Total UA by 5%. <br /> Above Grade Walls- R-21 Int 0.056 1,653 92.6 0 0 0 0 0 m <br /> Floors- R-38 0.025 1,Q26 25.7 Glass Doors 2 5 0 6 10 <br /> 0.5CREDITS <br /> Below Grade Walls- R-21 Interior 0.042 0 0.0 0 0 0 0 0 � <br /> Slab Below Grade- R-5 Thermal Break at slab edge 0.570 - 0.0 0 0 0 0 0 <br /> Slab on Grade - R-10 Perimeter 0.540 - 0.0 Non-Glass Doors 1 3 0 6 8 � <br /> 1 2 s 6 8 HIGH EFFICIENCY HVAC EQUIPMENT 3a: <br /> Duct Leakage Coefficient o 0 0 0 o Gas, propane or oil-fired furnace with minimum AFUE of 94%, or - <br /> Location of Ducts- Unconditioned Space 1.1 Tota) SF 32a Gas, propane or oiled-fired boiler with minimum AFUE of 92% <br /> To qualify to claim this credit, the building permit drawings shall specify the option <br /> sum of ua 239 nnechanical ventilation being selected and shall specify the heating equipment type and the minimum <br /> Envelope Heat l.oad 11692 equipment efficiency. <br /> Air Leakage Heat Load 6602 This Project Floor Area 1,470 Q <br /> Building Design Heat Load 18295 This Project Number of Bdrs 4 �.0 CREDITS <br /> Building Duct Heat Load 20124 <br /> Maximum Heat Equipment Output 28174 Table M1507.3.3(1) <br /> Continuous Whole House Mechanical Ventilation � <br /> EFFICIENT WATER HEATING 5a: J <br /> TABLE R402.1.1 FI Area 0-1 Bdrs 2-3 Bdrs 4-5 Bdrs 6-7 Bdrs >7 Bdrs All showerhead and kitchen sink faucets installed in the house shall be rated at 1.75 � <br /> INSULATION AND FENESTRATION REQUIREMENT BY COMPONENT(a) <1500 30 45 60 75 90 GPM or less. All other lavatory faucets shall be rated at 1.0 GPM or less. W <br /> 1501-3000 45 60 75 90 105 C � <br /> FENESTRATION U-FACTOR (b) 0.28 3001-4500 60 75 90 105 120 To qualify to claim this credit, the building permit drawings shall specify the option W <br /> SKYLIGHT(b) U-FACTOR o.5 4501-6000 75 90 Zo5 Zzo 13s being selected and shall speci#y the maximum flow rates for all showerheads, kitchen <br /> GLAZED FENESTRATION SHGC(b,e) NR 6001-7500 90 105 120 135 150 sink faucets, and other lavatory faucets. <br /> V <br /> CEII.ING R-VALUE (k) 49 >7500 105 120 135 150 165 <br /> WOOD FRAM WALL (g,m.n} R-VALUE 21 INT O.5 CREDITS � <br /> MASS WAIL R-VALUE (i) 21/21 Table M1507.3.3(2) � <br /> FLOOR R-VALUE 38 Runtime Percentage and Multiplying Factor W <br /> BELOW GRADE (c,m) WALL R-VALUE 10/15/21 INT+TB 25% 33% 50% 66% 75% 100% EFFICIENT WATER I-IEATING 5c: � <br /> SLAB (d) R-VALUE AND DEPTH 10, 2 FT 4 3 2 1.5 1.3 1 Water heating system shall include one of the following: � <br /> For SI: 1 foot = 304.8 mm, ci = continuous insulation, int = intermediate framing. M1507.2 Recirculation of air. Exhaust air from bathrooms Gas, propane or oil water heater with a minimum EF of 0.91 W <br /> � and toilet rooms shall not be recirculated within a residence or CL. <br /> � ) or to another dwelling unit and shall be exhausted directly to Solar water heatin su lementin a minimum standard water heater. Solar water � <br /> a R-values are minimums. U-factors and SHGC are maximums. When g pp g <br /> insulation is installed in a cavity which is less than the label or design thickness of the outdoors. Exhaust air from bathrooms and toilet rooms heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the � <br /> the insulation, the compressed R-value of the insulation from Appendix Table shall not discharge into an attic, crawl space or other areas Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 � <br /> A101 .4 shall not be less than the R-value specified in the table. inside the building. Certified Solar Water Heating Systems. � <br /> or <br /> b The fenestration U-factor column excludes sk li hts. The SHGC column Electric heat pump water heater with a minimum EF of 2.0 and meeting the standards W � � <br /> � ) Y �9 M1507.3 Whole-house mechanical ventilation system. , <br /> applies to all glazed fenestration. Whole-house mechanical ventilation systems shall be of > p <br /> NEEAs Northern Climate Specifications for Heat Pump Water Heaters. I` <br /> designed in accordance with Sections M1507.3.1 through � .� <br /> (c) "10/15/21 +TB" means R-10 continuous insulation on the exterior of the wall, M1507.3.3. To qualify to claim this credit, the building permit drawings shall specify the option � � <br /> or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation being selected and shall specify the water heater equipment type and the minimum - <br /> plus a thermal break between the slab and the basement wall at the interior of M1507.3.1 System design. The whole-house ventilation equipment efficiency and, for solar water heating systems, the calculation of the Q � <br /> . the basement wall. "10/15/21 +TB" shall be permitted to be met with R-13 cavity system shall consist of one or more supply or exhaust fans, minimum energy savings. � J <br /> insulation on the interior of the basement wall plus R-5 continuous insulation on or a combination of such, and associated ducts and controls. A. <br /> the interior or exterior of the wall. "TB" means thermal break between floor slab Local exhaust or supply fans are permitted to serve 1.5 CREDITS � <br /> and basement wall. as such a system. Outdoor air ducts connected to the return �[ � <br /> side of an air handler shall be considered to provide supply W � <br /> (d) R-10 continuous insulation is required under heated slab on grade floors. See ventilation. a. Projects using this option may not use Option 1 a, 1 b or 1 c. Q <br /> R402.2.9.1. � � <br /> M1507.3.2 System controls. The whole-house mechanical b. Projects may only include credit from one space heating option, 3a, 3b, 3c or 3d. When "� <br /> (e) There are no SHGC requirements in the Marine Zone. ventilation system shall be provided with controls that a housing unit has two pieces of equipment (i.e., two furnaces) both must meet the � � <br /> enable manual override. standard to receive the credit. � � <br /> (i) The second R-value applies when more than half the insulation is on the <br /> interior of the mass wall. M1507.3.3 Mechanical ventilation rate. The wholehouse c. Plumbing Fixtures Flow Ratings. Low flow plumbing fixtures {water closets and urinals) DATE: <br /> � mechanical ventilation system shall provide outdoor and fittings (faucets and showerheads) shall comply with the following requirements: <br /> (k) For single rafter- or joist-vaulted ceilings, the insulation may be reduced to R- air at a continuous rate of not less than that determined in 11/17/2017 <br /> 38• accordance with Table M1507.3.3(1). 1. Residential bathroom lavatory sink faucets: Maximum flow rate - 3.8 Umin (1.0 gaUmin) <br /> when tested in accordance with ASME A112.18.1/CSA B125.1 . EHD JOB: <br /> (m) Int. (intermediate framing) denotes standard framing 16 inches on center with Exception: The whole-house mechanical ventilation 2. Residential kitchen faucets: Maximum flow rate � 6.6 Umin (1.75 gal/min) when tested <br /> headers insulated with a minimum of R-10 insulation. system is permitted to operate intermittently where the in accordance with ASME A112.18.1/CSA B125.1. 2109 <br /> system has controls that enable operation for not less 3. Residential showerheads: Maximum flow rate - 6.6 Vmin (1 .75 gal/min) when tested in <br /> (n) Log and solid timber walls with a minimum average thickness of 3.5 inches than 25-percent of each 4-hour segment and the ventilation accordance with ASME A112.18.1/CSA B125.1. <br /> are exempt from this insulation requirement. rate prescribed in Table M1507.3.3(1) is multiplied SHEET: <br /> by the factor determined in accordance with Table � � <br /> M1507.3.3(2). ���l���f,._,)" ��� ������ � <br />
The URL can be used to link to this page
Your browser does not support the video tag.