Laserfiche WebLink
-- <br /> COPYRIGHT NOTICE <br /> THIS DOCU�ENT AND THE INFOR�IATION HEREIN <br /> REIATiNG TO THE PROJECT ARE AN INSTRU�IENT <br /> OF SERV�CE AND THE COPYRIGHTED PROPERTY OF <br /> BOTESCH, NP,SH AND HALL ARCHITECTS, P.S. NO <br /> PART HEREOF SHALL BE COPIED, DUPLICATED, <br /> DISTRIBUTED, DISCLOSED OR �ADE AVAILABLE TO <br /> OTHERS OR USED TO ANY EXTENT �HATSOEVER, <br /> Board of Directors: <br /> EXCEPT AS EXPRESSLY AUTHORIZED IN RITING <br /> BY BOTESCH, NASH AND HALL ARCHITECTS, P.S. <br /> Ted Wenta, P'resident <br /> Carotiine Mason, Vice-P'residcnt <br /> Traci Mitchell, Legislative aepresentative <br /> Caroti Andrews, Member � <br /> P�am LeSesne, Member <br /> • + <br /> Superintendent: - <br /> Dr. Gary Cohn <br /> � w <br /> � <br /> Q <br /> 0 <br /> DESIGN TEAM z o . <br /> o � <br /> � <br /> N � <br /> OWNER: PROJECT ARCHITECT: ELECTRICAL ENGINEER: TELECOM AND SECURITY ENGINEER: W W <br /> � � <br /> EVERETT SCHOOL DISTRICT N0. 2 BOTESCH, NASH & HALL ARCHITECTS, P.S. AWA ELECTRICAL CONSULTANTS, INC. HARGIS ENGtNEERS <br /> Fcrcilities crnd Planning Department 2727 Ocrkes Avenue, Suite 100 19015 36th Avenue West, Suite E ; 1201 3rd Avenue, Suite 600 <br /> 3900 Brocrdway Everett, WA 98201 Lynnwood, WA 98036 Seattle, WA 98101 <br /> Everett, WA 98201 (425) 259-0868 (425) 775- 1799 (206) 448-3376 <br /> (425) 385-4190 <br /> � <br /> � <br /> Q . <br /> � <br /> � �- <br /> o r� <br /> � � � <br /> _ � I <br /> GEN ERAL N OTES ABBREVlATION S SYM BOL LEGEN D PROJECT DATA DRAWI N G IN DEX � N <br /> � � � <br /> � � <br /> 1. Atiti construction shatiti comptiy with the 2015 Internationati Buil.ding a � N�� � c/� � � <br /> A.B, ANCNOR BOLT L LONCr, LENGTN DATUM P'OINT MAJOR� AP�pLICABLE CODES <br /> Code �IBC�, Washingt,on St,ate regulations for barrier-free design, aBv aeove LAM �aMiNare INTEFcNAT10NAL BUILDING CODE - 2015 GI.ON COVE� SNEET � � ,�, a <br /> A/C AIR CONDITIONING LAV LAVATORY GI.I NAWTNOt�NE KEY PLAN Z I� <br /> Washington '�JtQte Energy Code, At'1C� A�� appl.icab1.e 1.oca1. codes, ACT ACOUSTICAL GEILING TILE 1b, s� P"OUND WASNINGTON STATE BUILDING CODE � <br /> ordinances Qt'ld standards. AD AkEA DRAIN LF LINEAR FOOT DETAIL NUMBER � � <br /> CNAPTER 51-50 WAC � � <br /> ADJ ADJUSTABLE LL LIVE LOAD AkCNITECTURAL � O � <br /> AFF ABOVE FINISH FLOOR LOC LOCATION p INTER'NATIONAL P'LUMBING CODE - 2015 U � � � <br /> ALUM ALUMINUM LT LIGNT INTEFcNATIONAL MECNANICAL CODE - 2015 <br /> ALT ALTEI�NATE LP LOW P'OINT `' A-000 ADI.I NAWTNOf�NE DEMO P'LAN � }' � <br /> 2. The Contractor is to Verify atiti existing conditions dimensions r �` wASNiNGTON STATE ENEkGY CODE - 2015 � � <br /> � � APPkOX ApP'ROXIMATE AD2.1 NAWTNOf�NE DEMO kEFLECTED CEILING P'LAN � � <br /> detai�s, etc, and notify the Architect of any and atiti discrepancies aacN AI�CHITECT M �..� SNEET NUMBEk A1.1 NAwTNOkNE FL00� P'LAN � � � o <br /> ASPH ASpHALT � <br /> rior to roceedin with the work, AUTO AUTOMATIC MAs MASONRY A2.1 NAWTNO�NE �EFLECTED CEILING P�LAN <br /> P P g MAT MATEI�IAL ; I <br /> aG�. AGGREGATE A7.1 NAWTNORNE INTERIOF� ELEVATIONS � �, N <br /> Ma,x MAXIMUM NAI�ITNOR�NE ELEMENTARY SCNOOL Aq,l NAWTNOI�NE SCNEDULES AND WALL TYP'ES <br /> B MECH MECHANICAL DETAIL NUMBEf� <br /> 3, �O I'lOt sca�.e drawings; dimensions govern. The Contractor BD BOAI�D MFD MANUFACTUI�ED 1105 P'OP�LAR� ST(�EET a N <br /> BLDG BUILDING MFR MANUFACTURIER 0 EVERETT WA qS2OI ELEGTR�ICAL a�� � <br /> shatiti notify the Architect immediatetiy of any and a1.ti BLK s�oc�c MH MANHOLE a-000 � � <br /> discre ancies. The drawin scaties are indicated to rovide visual. BLKG BLOCKING M�N MINIMUM o 0 <br /> p g p B�� BE�� nisc MISCELLANEOUS CONSTRUCTION TYP'E (CNAP'TEf� 6,� E0.0 COVEF� SNEET <br /> B M B E A M M,O. MASONI�Y OPENING SNEET NUMBE(� V B S P'k I N K L E t�E D EI,O NAWTNOf�NE LIGNTIN G P'LAN � Q <br /> p r o p o r t i o n a n d s h o u ti d b e v e r i f i e d w i t h s i m i l,a r d r a w i n g s a n d 1.i s t e d 8.�, BENCH MARK r�n M E T AL E2.o NAWTNOf�NE P'OWER P'LAN � N � <br /> dimensions. BSMr BASEMENT N N r,oaTu SECTION NUMBEI� OCCUP�ANCY �CNAPTER 3� E3.0 NAWTNOI�NE I�ISER AND P�ANELS N � � <br /> BTM BOTTOM NA NOT AppLICABLE E <br /> BTWN BETWEEN NIC NOT IN CONTRACT � TELECOM AND SECUkITY <br /> 4. Atiti dimensions are to be center 1.ine of stud, or face of No NUMBEPo a-000 <br /> concret,e watiti, untiess noted otherwise, cae � CABINET Nor� NOMINAL T0.1 TELECOM AND SECURITY LEGEND AND NOTES <br /> c.a. CATCN BASIN NTs NOT TO SCALE SNEET NUMBER T1.1 NAWTNOI�NE TELEGOM AND SECUaITY FLOOt� pLAN <br /> c� CONTPoOL JOINT T2.1 SECUR'ITY ENLARGED P'LANS AND ELEVATIONS � <br /> 5. Where devices or items or arts thereof are referred to in ��,� CENTER LINE o <br /> P c�� CEILING oa OVERALL WALL SECTION LETTEk T3.) TELECOM AND SECURITY DETAILS � i , <br /> sin ular it i5 intended that 5uch shatiti a �- to as man such c�o CL05ET o.C. ON GENTER� (5) T4.1 TELECOM AND SECURITY DETAILS MONITO�E� AUT�II�ATIC FIRE W <br /> g / PI� Y Y CLR CLEAPo OD OUTSIDE DIAMETEa <br /> devices items or arts as are re ired to ro erti com 1.ete the cMu GONGfdETE MASONRY UNIT OPNG OPENING a o0o T5.1 TELECOM AND SECUR'ITY SGNEDULES � DETECTION SYSTEIVI REQUIRED � <br /> / p � P P Y I� C O C L E A N O U T O P'P O P P O S I T E <br /> w0t.,�. COL COLUMN O,F,C,I, Ot�INER FUR�NISNED- <br /> CONC CONCR�ETE CONTRACTOPo INSTALLED s N E E T N U M e E a S U P E R V I S E� AUTOMATIC � , <br /> C O N T C O N T I N U E (C O N T I N U O U S) O,F,O,I, o�NER F��N�sNEo- SPRINKLER SYSTEM REQUIRED <br /> CTR COUNTE�d Ot�(NER' INSTALLED <br /> 6. It shatiti be the responsibi"�ity of the Contractor to tiocate ati� cpr CARPET � INTERIOR ELEVATION NUMBER ' <br /> C.P,0,1, CONTRACTOR FURNISHED- p � � <br /> existing UtI�It185 whether S�'l0UJt1 hereon Ot" t'lOt and to protect them OWNEPo INSTALLED pER PERIMETER � <br /> €rom damage. The Contractor shatiti bear ati1. expense of repair or o p�. Pf�OPER'TY LINE 4 a-000 2 <br /> DBL DOUBLE PLAM PLASTIC LAMINATE �4dditional Permits Are Requir�d � � <br /> replacement Of UtI�It18S Or other property damaged by operations It'1 DF DR�INKING FOUNTAIN p�g�, PLUMBING � <br /> II DIA Q� DIAMETEk For T'his Project To Include. <br /> COt'1�Ut'1CtI0t'1 with the execution Of f'lIS UJOY'1[, DIM DIMENSION P'LF POUNDS PER LINEAR FOOT 3 SNEET NUMBER <br /> DISP' DISpENSEk P'LYWD PLYWOOD <br /> PNT PAINT (ED) `�, S rinkier <br /> DN �N pR pAll� <br /> h n r r i eri AY1G� con orm Y" IY' m n DR DEER PREFIN PREFINISHED � ' �' e <br /> _ 7. T e Co t acto w titi v f f to a�ti e e e ts of - - - � � �I Plumbing %� Pe���rm <br /> 1 1_ y � DTL D�TAIL p�F POUNDS pER� SQUARE FOOT 1-NI� WALL �DEMD WALL � Mechanical ��J r�� � � <br /> A�� Utll.Ity companies, Ur1�GSS noted other�.uise Irl the p�ans Arld DS DOWNSP'OUT pg� POUNDS pER� SOUARE INCH ,�` � i' <br /> s ecifications. E F'TN PAkTIT10N � <br /> p Ph/C POLYVINYL CNLOR'IDE <br /> E EAST 2-N(� WALL �EXISTING WALL � Ef@Ctt'IC�I <br /> EA EAGN � � <br /> 8. Existin elevations and locations to be oined sha1.1. be verified EB EXPANSION BOLT �A I�ETU�1N AIR' � J <br /> 9 J EJ EXPANSION JOINT (��P R'EFLECTED GEILING P'LAN 2-Nk SMOKE WALL NEW WALL � � <br /> b the Gontractor before construction 1.a out. If the differ from E� ELEVATION ao �ooF o�A,N <br /> y y � ELEC ELECTRIC (AL) R'ECPT R'ECEPTAGLE <br /> those shown Ot1 the drawings, t�'lE Contractor shatiti notify the EQUIR EQU P'MENT F�EF R'EFERENCE/R'EFR'IGERATOR' q-N� wA�� �ire deteGtion a�d alarm sysiem updates P� � <br /> EN! EACH WAY R�EINF R'EINFOR�GE (MENT) +'pa bQ C2QUif�'i��1f0Ug�19U�p@ft7llt�f@�. V� <br /> Architect, so modifications can be made before proceeding with the �eo�o R'EQUIR'E (D) y = <br /> UJOrt[, EXIST EXISTING r' <br /> EXT EXTEf�IOk R'EV R'EVISE(D);R'EVISION;R'EVER'SE �ontaet Firs[?�pa►��nen1 at 425-257-81 <br /> RM ROOM 0 ta clarify s�ape, a � <br /> F R.O, ROUGH OPENING <br /> FD FLOOR DRAIN ���.�• RIGHT OF WAY ��$C�fl.a{permit required from P�rmit Services <br /> q. A1-ti debris shatil. be removed from the premises and atiti areas FDN FOUNDATION R.T.U. RlOOF TOP UNIT KEYNOTE NUMBEf� � � <br /> FE FII�E EXTINGUISHER RB f�ESILIENT BASE :!J;il@W iri+t}!k pC C@J1510liS t4�25-257•$��Q�.Alarm <br /> shati� be tief t in broom cl.ean condition At a1.1. times. FEC FIkE EXTINGUISNER' CABINET �i11��deteGtion permit a�plicati�n�nd drawmgs <br /> FH FIRE NYDRANT r�, s �TN � i,(} ,,��$�J�3tTli���'(��I��.'Ct��l t�}��%1�fi�l�i�J�TVIC$S. a � <br /> FIN FINISH SAN SANITARY } � <br /> 10. The Contractor shalti take Q�� necessary precautions t0 ensure FIN FLPo FINISH FLOOR SB SPLA5H BLOCK DEMO KEYNOTE NUMBER� � <br /> FLPo,FL, FLOOR � $OLID CORE � � <br /> the safety of the OCCUpAt'1tS At'ld �.uorkers At atiti times, FLUOR FLUORESCENT c,�H SCHEDULE <br /> FT or (') FOOTE(D)(ING)/FIRE RATED 5D STORM DRAIN I�IATCN L I N E - � <br /> FTG FOOTING SEAL SEALANT � � <br /> ��. Fire extinguishers: Verify the req�irements and tiocations UJIt�'1 FUR FUR'RED/FUR�RING SF SQUAf�E FOOT � � � � � <br /> , SHT BNEET <br /> the f ire mars�ati. The Gontractor �s to supptiy f ire extinguishers and � SIM SIMILAR� <br /> .. <br /> SPEC SPECIFICATION f�ICTUI�E NUMBEf� ���������� ���i� ��������� „ � , _ <br /> cabinets AS re ired and/or AS indicated OYl the drawin S. GA GAGE, GAUGE � �A�E � � <br /> � � g GALV. GALVANIZED <br /> GB GI�AB BAI� SERV SERVICE O <br /> qq 1 GG GENERAL CONTRACTOPo SS SANITARY SEWEf� �y�'h� Fire �larshal, � � ' �� <br /> I2. Sound It'15U�At8 Abl� 1.umbin UJQt��S. GL GLASS GLAZING SST STAINLESS STEEL f�EVI510N CLOUD �- <br /> P 9 ' STC SOUND TRANSMISSION CLA55 <br /> GWB GYPSUM WALLBOARD-TYpE X STD STANDARD I�EVISION NUMBER <br /> 13. The plans and specifications are minimums and where details Hc H NOLLOW GORE sTs STORM SEVIER <br /> STRUCT STRUCTUR�AL; STRUCTUR�E <br /> QY"6 t'lOt specificaltiy shown, consistent practices shatil be used. NDW HAk'DWAR'E SUP SUP'PLY O 3��s <br /> Codes AI'1C� ordinances tA1[6 recedence over �ans AYId s ecif ications HDWD HAR'Dl�(OOD SUSR SUSPEND (ED) - - ` <br /> p p p SSV STAIN 3 VARNISH <br /> NM HOLLOVd METAL � REGISTERED <br /> ACId �.uherever inconsistencies BXISt� It wititi be the Contractor's NOR�IZ NOF�IZONTAL SVyS STORM WATER SEV�IER� � Y <br /> ARCHITECT <br /> responsibil.ity to immediatetiy notify the Owner and provide NT HEGHT�E� r <br /> HTG HEATING T.O.C. TOP OF CURB NDREW M. AL <br /> acceptabtie corrections At C10 additionati charge, HTR HEATER TELE TELEPHONE �SECTION LETTEf� �����������������������C�� STATE OF WAS' NGTON <br /> HVAC HEATING, VENTILATING TEMP TEMP'ORARY <br /> APP�t�V�������I�I��ll��1���� <br /> AND AIR CONDITIONING TtG TONGUE d GF�OOVE XX - - XX ,���Lf�,������,'t���T;��'��� ���� <br /> 14, Use 5/8-inch GWB Tv e X in ati1. 1.ocations unl.ess noted uw HOT WATER Tv TELEVISION , <br /> / / p / T.0.6. TOP OF BEARING <br /> otherwise, I T,0.5. TOp OF STEELET �����������������'A�9�� <br /> ID INSIDE DIAMETEf� T.O.N(. TOP OF WALL <br /> INCL INCLUDE TYP' TYpICAL <br /> 15. The Contractor shal.ti provide mechanica1., p1.umbing and '" °�' �"� '"c" <br /> electrical. permits, INSUL INSULATION u,v,� a Y �oB. NG. <br /> INT INTERIOa V VOLT <br /> V.C.T. VINYL COMP'OSITION TILE �' <br /> J VERT VER'TICAL GOLUMN GRID REFERENCE Thi$ permit review do�s not cover i�-10ii <br /> JST. JOIST W WEST ����rai ADA, FHA or HUD regulations <br /> 16. Sheet-metati flashing at skytiights, roof hatches, rooftop �TR �,A,TEa <br /> ar�d standarcis, includingthe DATE �-i7 <br /> mechanicati units, masonry head sitil.s, soffits, pdrapet watils, K �c, waTER c�osET ��irh{ousingAccessibilitYGuidelines. <br /> �c� KILOWATT �p ��p � ti�n�e with thase regulations is the �- <br /> reg1ets, expansion joints, etc,, shatiti be insta�'l.ed as recommended ������������af th��wnEr r�f the building. <br /> HlH WATE(� HEATER DRAWN BY <br /> by SMACNA (Sheet Metati and Air Conditioning Contractors Nationati w�o V1ITNOUT � �R <br /> Association) manuati. �T wE�GNr <br /> W.W.F, WELDED WIR'E FABR'IC <br /> W.W.M. WELDED WIF�E MESN <br /> ���,� �� ����E� CHECKED BY <br /> 17. Penetrations through rated construction shatiti be protected by pkOJECT NOF�TN �H <br /> U.L. Listed T stop material.s and methods per 2015 IBC. �����W�� ��� ����,� <br /> 18, Seatiing caul.king and weather-stripping shatil- be instatil.ed to S"EET T'T�E � <br /> provide a complete buil.ding enve1.ope NOR'TN Permit#: B1706-0Q7 <br /> s�t�Rddr�55: liia POP�aR sr � <br /> lq. Prior approva1. is req�ired on a1.1. changes or al.terations to the DOOR' NUMBEI� Owner: EVERETTSCHOOLDIST2 <br /> approved p�ans oo� <br /> Tenant: HAWTHORNE ELEM SCHOoL <br /> App. Date: 6/5/2017 <br /> WINDOW NUMBER Proposed Use: CQMMERCIAL <br /> Description: ADQ INT�OOR/WALLTO CREATE SECURE <br /> � ENTRY VESTIBLE-HAWTHORNE <br /> '�,�, ��/�cs��;7. <br /> WALL TYPE /� � �,1f'' � <br /> 00 '�� `���'���� �+ �� <br /> Reviewed By:_`I I` / .� Date: ���_�'���� <br /> a�i <br /> /Office Set 1ob Site Set Fire/Planning Set <br /> F: ��- f <br /> � � ��� �� ��� <br /> ��I�OOM NAME <br /> ROOM <br /> oo, �G 1 . 0 H W <br /> � <br /> (�OOM NUMBEf� <br /> H <br /> W <br />