Laserfiche WebLink
i � il! .I_ <br /> �� <br /> � 101tE � l�£AN <br /> OF SFRViCE M�11� OF <br /> �OIE9C01,IMBH 6WD W�L ARCFi1�IS,P.S.ND <br /> FAR!FEA�F SHN.�BE COP�D; <br /> A�BREVIAT1bNS G�NERAL NU1'ES �� � � � � � � � � <br /> an�aR us�ro�oc�m�r <br /> T0.1 TELECOM AND SECURITY LEGEND AND NOTES �^s°� �� <br /> er ea��w�ao wui �s <br /> A AMPERE MC MAIN CROSS CONN�CT; M�TAL CLAD (CABLE) 1. PERFORM WORK IN ACCORDANCE WITH APPLICABLE .��� / EXISTING ELECTRICAL TO BE REMOVED TELECOMMUNICATIONS DEVICE acp ACCESS CONTROL PANEL T1.1 HAWTHORNE TELECOM AND SECURITY FLOOR PLAN <br /> AC AIR CONDITIONING; ALTERNA`fING CURRENT; MCC MOTOR CONTROL CENTER NATIONAL AND STATE CODES AS AMENDED LOCALLY (X=REPRESENTS THE#OF TELECOMMUNICATIONS MODULES) T2.1 SECURITY ENLARGED PLANS AND ELEVATIONS <br /> ABOVE COUNTER AND ENFORCED BY THE AHJ. EXISTING ELECTRICAL TO REMAIN (W=TELECOMMUNICATIONS WALL PHONE MTD AT+48��AFF) CREDENTIAL/CARD READER <br /> MCB MAIN CIRCUIT BREAKER (B=BLANK COVER PLATE) _� (CR=CARD READER,WALL MOUNTED) T3.1 TELECOM AND SECURITY DETAILS <br /> AF AMP FRAME MDF MAIN DISTRIBU710N FRAME <br /> 2. OBTAIN AND PAY FOR PERMITS REQUIRED FOR -�s (CR/P=CARD READER WlPIN,WALL MOUNTED) <br /> AF AMP FUSE; AMP FRAME MDP MAIN DISTRIBUTION PANEL NEW ELECTRICAL WORK x (F=MODULAR FURNITURE DEVICE) �R (CR/M=CARD READER, MULLION MOUNTED) T4.1 TELECOM AND SECURITY DETAILS <br /> AFF ABOVE FINISHED FLOOR INSTALLATION OF WORK. ARRANGE AND SCHEDULE Y (AC=ABOVE COUNTER DEVICE) <br /> MFR MANUFACTURER REQUIRED INSPECTIONS. �s=suRFacE MouNT> T5.1 TELECOM AND SECURITY SCHEDULES <br /> AG ABOVE GRADE MH MANHOLE - - � — MATCHLINE OR PROPERTY LINE (WAP=WALL MOUNTED WIRELESS ACCESS POINT DATA DEVICE) �s DOOR POSITION SWITCH <br /> AHJ AUTHORITIES HAVING JURISDICTION MIN MINIMUM 3. DRAWINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE � <br /> ABOVE CEILING TELECOMMUNICATIONS DEVICE DE DOOR ENTRY STATION, WALL MOUNTED <br /> AHU AIR HANDLING UNIT MLO MAIN LUGS ONLY COMPONENTS AS REQUIRED FOR A COMPLETE - - - - ENLARGED PLAN BOUNDARY r--� (X=REPRESENTS THE#OF TELECOMMUNICATIONS MODULES) 0 <br /> AIC AMPERE INTERRUPTING CURRENT M� MULTIMODE OPERATIONAL SYSTEM WHETHER OR NOT L�� � <br /> SPECIFICALLY SHOWN ON THE DRAWWGS. AP �(AP=ACCESS POINT DEVICE) Ms DOOR MASTER STATION, DESK TOP <br /> AL ALUMINUM MPOE MAIN POINT OF ENTRY � (SV=SECURITY VIDEO CAMERA) <br /> ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MPOP MAIN POINT OF PRESENCE DETAIL/PLAN IDENTIFIER <br /> AS AMP SWITCH 4. DEVICE LOCATIONS ARE APPROXIMATE. COORDINATE E1.1 L� FIRE RESISTANT 3/4" PLYWOOD BACKBOARD SECURITY WALL MOUNTED BUTTONS <br /> MTD MOUNTED DEVICE LOCATIONS AND ELEVATIONS WITH � (DR=DOOR RELEASE) <br /> AT AMP TRIP I�ITS MANUAL TRANSFER SWITCH APPROPRIATE DOCUMENTS WCLUDING CASEWORK A �� <br /> (LD=LOCKDOWN) <br /> ATS AUTOMATIC TRANSFER SWITCH SHOP DRAWINGS AND ARCHITECT'S INTERIOR SECTION IDENTIFIER � TWO-POST EQUIPMENT RACK (PB=PANIC/DURESS) �5 <br /> ATM ASYNCHRONOUS TRANSFER MODE N N�UTRAL ELEVATIONS PRIOR TO ROUGH-IN. E1.1 �i <br /> AV AUDIO VISUAL (N) NEW � 6" DOUBLE-SIDED VERTICAL MANAGEMENT � SECURITY UNDER DESK MOUNTED BUTTONS � <br /> AWG AMERICAN WIRE GAUGE 5. LOCATIONS OF RACEWAY, PATHWAY AND SIMILAR A ELEVATION IDENTIFIER • �(DR=DOOR RELEASE) <br /> NAC NOTIFICATION APPLIANCE CIRCUIT ITEMS ARE SHOWN SCHEMATICALLY. COORDINATE E1.1 � „ (LD=LOCKDOWN) <br /> NEC NATIONAL ELECTRICAL CODE INSTALLATION, INCLUDING BUT NOT LIMITED TO 10 DOUBLE-SIDED VERTICAL MANAGEMENT (PB=PANIC/DURESS) <br /> BAS BUILDING AUTOMATION SYSTEM NATIONAL ELECTRICAL MANUFACTURERS CABLING, TELECOMMUNICATION PATHWAYS AND REVISION DEFINITION AREA, AREA ENCIRCLED <br /> NEMA CONTAINS CHANGES MADE SUBSEQUENT TO � 12" DOUBLE-SIDED VERTICAL MANAGEMENT �s KEYED SWITCH, WALL MOUNTED <br /> BATT BATTERIES ASSOCIATION SPACES, AND EXACT LOCATION OF HORIZONTAL AND Ks � <br /> BKBD BACKBOARD NF NON-FUSED BACKBONE CABLING WITH LOCATIONS OF FIXED PREVIOUS ISSUE <br /> BIL BASIC IMPULSE INSULATION LEVEL NIC NOT IN CONTRACT CASEWORK AND BUILDING CONDITIONS AFFECTING THE 8 3.65" DOUBLE-SIDED VERTICAL MANAGEMENT -�s Ao AUTO OPERATOR BUTTON, WALL MOUNTED <br /> BKR BREAKER NL NIGHT LIGHT WORK OF THIS CONTRACT. � REVISION CALLOUT <br /> BLDG BUILDING � 6" DOUBLE-SIDED VERTICAL MANAGEMENT -�►- REQUEST TO EXIT DETECTOR, WALL MOUNTED <br /> OS OCCUPANCY SENSOR 6. COORDINATE TELECOMMUNICATIONS WORK WITH THAT <br /> OF OTHER TRADES. REFER TO ELECTRICAL, � FLAG NOTE TAG � <br /> C CONDUIT; DEGREES CELSIUS OFC OPTICAL FIBER CABLE MECHANICAL, ARCHITECTURAL, STRUCTURAL, CIVIL, � WALL MOUNTED ENCLOSURE �-- REQUEST TO EXIT DETECTOR, CEILING MOUNTED <br /> CAB CABINET OHL OVERHEAD LINE AND LANDSCAPE DRAWWGS AND SPECIFICATIONS. O DEMOLITION NOTE TAG <br /> CAT CATEGORY OL OVERLOAD <br /> COORDINATION SHALL OCCUR PRIOR TO FABRICATION, � FLOOR MOUNTED SERVER ENCLOSURE � REQUEST TO EXIT, INTEGRAL MICRO SWITCH r �, <br /> CATV COMMUNITY ANTENNA TELEVISION OSP OUTSIDE PLANT PURCHASE, AND INSTALLATION OF WORK. O EQUIPMENT TAG � N M <br /> C B C I R C U I T B R E A K E R � 110 BLOCK WITH LEGS � REQUEST TO EXIT BUTTON, WALL MOUNTED � � �' <br /> CCTV CLOSED CIRCUIT TELEVISION P POLE 7. NEW CABLING INSTA L L A T I O N S S H A L L B E C O N C E A L E D I N AHU-01 MECHANICAL EQUIPMENT TAG - <br /> WALL, CEILINGS, AND BELOW RAISED FLOOR SPACES N <br /> CLG CEILING PBX PRIVATE BRANCH EXCHANGE UNLESS OTHERWISE NOTED ON THE DRAWINGS. s�Q HORN, WALL MOUNTED 0� 3 N <br /> CM CEILING-MOUNTED PF POWER FACTOR CABLING IN ACCESSIBLE CEILING SPACES SHALL BE AHU MECHANICAL EQUIPMENT TAG �� � � ��� � • L � <br /> CO CONDUIT ONLY PH PHASE INSTALLED AS OPEN CABLING NEAR STRUCTURES AND s� STROBE, WALL MOUNTED N � <br /> ^ VIDEO SECURITY CAMERA MOUNTING TYPES � � > x <br /> COW COMPUTER ON WHEELS PIR PASSIVE WFRARED WALLS OR AS SPECIFICALLY NOTED ON DRAWINGS. _�_�°°��� � w v <br /> SEE SPECIFICATIONS FOR SUPPORT REQUIREMENTS. Y (P=PENDANT MOUNTED) � STROBE/HORN, CEILING MOUNTED ., �-�- <br /> CR CONTROLLED RECEPTACLE PIV POST INDICATING VALVE N NORTH ARROW �(R=ROOF PARAPET MOUNTED) � � • <br /> CT CURRENT TRANSFORMER PNL PANEL 8. PROVIDE FIRESTOPPING SYSTEMS FOR CONDUIT AND (W=WALL MOUNTED W/BRACKET) � � -�-+ • <br /> Ps DOOR HARDWARE POWER SUPPLY (DIV 08) V V o <br /> CU COPPER PP PATCH PANEL RACEWAY SYSTEMS AT PENETRATIONS, SLEEVES AND LOCATION WHERE PICTURE WAS TAKEN AND X (X=QUANTITY OF DOORS) � � .— op <br /> ;.. .. <br /> ;c-�- VIDEO SECURITY CAMERA ID �+ cc> <br /> PT POTENTIAL TRANSFORMER SLOTS OF FIRE RATED CONSTRUCT ON FOR 9O DIRECTION #��-(WHERE APPLICABLE REPRESENTS THE CAMERA#OR TYPE) EL ELECTRIFIED LOCKSET/EXIT DEVICE � � � o <br /> D D C D I R E C T D I G I T A L C O N T R O L P V C P O L Y V I N Y L C H L O R I D E H O R I Z O N T A L P A T H W A Y S A N D S P A CO <br /> � � <br /> DEMARC DEMARCATION POINT <br /> 9. MAINTAIN A MINIMUM SPACING OF 12" FROM c� C A M E R A, C E I L W G M O U N T E D E s E L E C T R I F I E D S T R I K E "N <br /> DISC DISCONNECT RCP REFLECTED CEILING PLAN � <br /> DIST DISTRIBUTION REC RECEPTACLE E L E C T R I C A L F E E D E R S AND BRANCH CIRCUIT WIRWG � Q � <br /> A N D 1 2" F R O M A U X I L I A R Y S Y S T E M CABLING. � AY� �� �� - c� C A M E R A, W A L L M O U N T E D ML E L E C T R I F I E D M A G N E T I C LOCK � � <br /> DSL DIGITAL SUBSCRIBER LINE REF REFER TO <br /> � � <br /> DWG DRAWING REV REVISION 10. MINIMUM SPACING FROM ELECTRICAL APPARATUS MH MAGNETIC HOLD OPEN DEVICE O � <br /> RM ROOM SUCH AS MOTOR DRIVEN EQUIPMENT AND � JUNCTION BOX � <br /> (E) EXISTING RU RACK UNIT TRANSFORMERS SHALL BE 6'-0". SPACING TERMINAL BLOCK N °� <br /> EA EACH REQUIREMENTS SHALL APPLY TO OPEN CABLING �F FURNITURE WALL FEED OUTLET BOX TB (MOUNTED ON DIN RAILS WITHIN PULL BOX) N � <br /> PATHWAYS WHERE EQUIPMENT IS LOCATED ON THE <br /> EF EXHAUST FAN SHT SHEET SAME FLOOR, FLOOR ABOVE, FLOOR BELOW, OR IN PULL BOX <br /> EIA ELECTRONIC INDUSTRIES ASSOCIATION SLC SIGNALING LINE CIRCUIT ROOMS ADJACENT TO SUCH EQUIPMENT AS THOUGH P XX �WHERE INDICATED,SUBCRIPT INDICATES PULL BOX NUMBER) <br /> ELEV ELEVATION SM SINGLEMODE WALLS AND FLOORS DID NOT EXIST. EXCEPTION: � <br /> EM EMERGENCY SMFC SURFACE-MOUNTED OPTICAL FIBER CABINET BUILDING CONSTRUCTION THAT RESULTS IN VAULT/ HANDHOLE �SUBCRIPT INDICATES TYPE) � <br /> EMT ELECTRICAL METALLIC TUBING SMR SURFACE METAL RACEWAY CONTINUOUS METALLIC BARRIER BETWEEN A � , <br /> ELECTRICAL APPARATUS AND CABLE PATHWAYS SHALL FLOORBOX �SUBSCRIPT INDICATES TYPE) <br /> ENCL ENCLOSURE SONET SYNCHRONOUS OPTICAL NETWORK gE CONSIDERED AS SUITABLE SEPARATION. A � <br /> EPM ELECTRONIC POWER METER SP SERVICE PROVIDER � POKE THROUGH �SUBSCRIPT INDICATES TYPE) � <br /> EPO EMERGENCY POWER OFF SPD SURGE PROTECTIVE DEVICE 11. PRIOR TO STARTING TELECOMMUNICATIONS A <br /> EQUIP EQUIPMENT SPEC SPEClFICATIONS INSTALLATION, CAREFULLY INSPECT INSTALLED WORK pOWER POLE, FLOOR TO CEILING <br /> ETR EXISTING TO REMAIN SPST SINGLE POLE SINGLE THROW OF OTHER TRADES AND VERIFY THAT SUCH WORK IS � ry <br /> EWC ELECTRIC WATER COOLER ST SHUNT TRIP COMPLETE TO THE POINT WHERE WORK MAY �.,J � <br /> STP SHIELDED TWISTED PAIR PROPERLY COMMENCE. NOTIFY THE ARCHITECT AND SURFACE METAL RACEWAY � <br /> ENGINEER IN WRITING OF CONDITIONS DETRIMENTAL � <br /> F FUSE; DEGREES FAHRENHEIT SVGA SUPER VIDEO GRAPHICS ARRAY � RACEWAY CONCEALED IN WALL OR IN CEILING � <br /> FA FIRE ALARM SW SWITCH TO THE PROPER AND TIMELY COMPLETION OF THE (EXPOSED IN UNFINISHEDAREAS) <br /> WORK. <br /> FAAP FIRE ALARM ANNUNCIATOR PANEL SWBD SWITCHBOARD o� � �' <br /> — RACEWAY RUN BELOW FLOOR OR BELOW GRADE <br /> FACP FIRE ALARM CONTROL PANEL 12. DO NOT BEGIN TELECOMMUNICATIONS INSTALLATION . <br /> ED BY OWNER TBB TELECOMMUNICATIONS BONDWG BACKBONE UNTIL ALL UNSATISFACTORY CONDITIONS ARE � � <br /> FBO FURNISH �� FLEXIBLE RACEWAY � � � <br /> FURNISHED BY OWNER INSTALLED BY TEL TELEPHONE RESOLVED. BEGINNING WORK CONSTITUTES � � <br /> FOIC ACCEPTANCE OF CONDITIONS AS SATISFACTORY. <br /> CONTRACTOR TELCO TELEPHONE COMPANY � RACEWAY (CIRCLE DENOTES VERTICAL <br /> FO10 FURNISHED BY OWNER INSTALLED BY OWNER TGB TELECOMMUNICATIONS GROUNDING BUSBAR TRANSITION) <br /> FSD FIRE SMOKE DAMPER 13. ROUTE CATEGORY 6/6A CABLES TO THEIR ASSIGNED P � <br /> TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION CROSS-CONNECT PER THE IDENTIFICATION LABEL AT <br /> TELECOMMUNICATIONS MAIN GROUNDING EACH TELECOMMUNICATIONS WORKSTATION DEVICE. � RACEWAY CONTINUATION `J � <br /> G GROUND TMGB gUSBAR � � <br /> TERMINATE ALL CABLES ON 48-PORT PATCH PANELS ON � RACEWAY STUB WITH BUSHING <br /> GF GROUND FAULT CIRCUIT INTERRUPTER TP TAMPERPROOF RACKS UNLESS OTHERWISE NOTED. � <br /> GFP GROUND FAULT PROTECTION TR 7ELECOMMUNICATIONS ROOM <br /> GND GROUND TTB TELEPHONE TERMINAL BOARD 14. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL [] RACEWAY SLEEVE WITH BUSHINGS � <br /> GRS GALVANIZED RIGID STEEL TV TELEVISION CONDUIT, OUTLET BOXES, JUNCTION BOXES, RACEWAY <br /> TVSS TRANSIENT VOLTAGE SURGE SUPPRESSION SYSTEMS, ETC. FOR A COMPLETE AND OPERATIONAL � EZ-PATH FIRE STOPPING SLEEVE � <br /> TYP TYPICAL PATHWAY SYSTEM FOR ALL TELECOMMUNICATIONS �, CABLE TRAY 12"W x 4"H OVERHEAD, UNLESS � <br /> HC HORIZONTAL CROSS CONNECT SYSTEMS PER THE SCOPE OF WORK INDICATED ON THE ;��;°,,;,;;;,�,�; , � � <br /> HID HIGH INTENSITY DISCHARGE CONSTRUCTION DRAWINGS AND BID SPECIFICATIONS. ��� \�\���"'`'" OTHERWISE NOTED � <br /> :�:: t; <br /> HP HORSEPOWER UG UNDERGROUND � � <br /> IBLE CEILINGS � � <br /> HTR HEATER UL UNDERWRITERS LABORATORIES 15. CABLE TRAY PATHWAYS ABOVE ACCESS CABLE TRAY, OVERHEAD LADDER TYPE � <br /> Hz HERTZ UON UNLESS OTHERWISE NOTED SHALL BE PROVIDED BY THE ELECTRICAL � <br /> UPS UNINTERRUPTIBLE POWER SUPPLY CONTRACTOR. CABLE TRAY PATHWAYS BELOW RAISED � <br /> FLOOR SPACES SHALL BE PROVIDED BY THE HOMERUN TO PANEL � � <br /> IC INTERMEDIATE CROSS CONNECT USB UNNERSAL SERIAL BUS TELECOMMUNICATIONS CONTRACTOR. � (INDICATES PANEL DESIGNATION AND CIRCUIT NUMBER) <br /> IBC INTERNATIONAL BUILDING CODE UTP UNSHIELDED TWISTED PAIR � � � <br /> IDF INTERMEDIATE DISTRIBUTION FRAME UV UNIT VENTILATOR #�j,� �'(GAUGE OF WIRE OTHER THAN AWG#12) � � � <br /> IEEE INSTITUTE OF ELECTRICAL AND ELECTRONIC �'0'�NUMBER OF CONDUCTORS <br /> ENGINEERS V VOLTS �(GROUND CONDUCTOR) <br /> �(PHASE CONDUCTORS) <br /> IG ISOLATED GROUND VA VOLT AMPERES <br /> (NEUTRAL CONDUCTOR) <br /> IMC INTERMEDIATE METALLIC CONDUIT VFD VARIABLE FREQUENCY DRIVE <br /> ISDN INTEGRATED SERVICES DIGITAL NETWORK <br /> y � <br /> W WATT; W I RE <br /> � <br /> J JUNCTION W/ WITH �� � � � ���� <br /> ��" ��� <br /> W/O WITHOUT <br /> � �, ����- <br /> kVA KILOVOLT AMPERE Wq WORKSTATION AREA <br /> r �' �r <br /> � �� <br /> kW KILOWATT WAN WIDE AREA NETWORK <br /> KCMIL THOUSAND CIRCULAR MILS WG WIRE GUARD � � <br /> KVAR KILOVOLT AMPERE REACTIVE �� �� <br /> WH WATT HOUR METER ����' �� <br /> WP WEATHERPROOF ���� <br /> � �� <br /> y <br /> LAN LOCAL AREA NETWORK <br /> LCP LIGHTING CONTROL PANEL XMFR TRANSFORMER <br /> �oa No. <br /> LEC LOCAL EXCHANGE CARRIER <br /> 17-1011 <br /> LT LIGHT y WYE <br /> LTG LIGHTING <br /> 6-2-17 <br /> M METER Z IMPEDANCE <br /> MAN METROPOLITAN AREA NETWORK � � <br /> MAX MAXIMUM <br /> D <br /> � � <br /> D� <br /> s�r nn.E <br /> I�OT ALL SYM�OL3 MAY APPEAR ON THE DRAWINGS TE LE CO M AN D <br /> � SECURITY <br /> LEGEND AND � <br /> NOTES <br /> s�r No. <br /> H n R G I S <br /> E N G I N E E R S a <br /> � ■ 1 <br /> �?�€�3��r��:r...,�<>,��:;a,}��a <br /> _���citiia,.�<:...,:;,���;��_��.�� <br /> . . � l.��i:r't1iLQJ.;)'.s`.�`:3 &'af Eti£:ytY..'�IZ <br />