Laserfiche WebLink
�111�_ � , <br /> DOOR TYPE LEGEND <br /> WINDOW FLASHING INSTALLATION <br /> � <br /> A B C D E F G _STEP 1 : INSTALL SILL FLASHING <br /> _ _ _ — — — /� PAPER AT BOTTOM OF <br /> E INTERIOR TO DECK GARAGE TO EXTERIOR, INTERIOR OVERHEAD DOOR @ UNIT 1 &2 GARAGE OVERHEAD DOOR @ UNIT 3 GARAGE OPENING, STAPLE ALONG TOP <br /> DOOR HARDWARE EXTERIOR TO ENTRY HOUSE TO GARAG INTERIOR TO PATIO @ UNIT 3 <br /> EDGE 3/8" FROM TOP OF PAPE <br /> ALL DOORS TO HAVE <br /> LEVER STYLE � ONL <br /> , <br /> HARDWARE W/ �❑ �� �' ,' / �/ � ��� ��� ��� ��� ��� ��� <br /> ANTI�UE PEWTER OR � � % � �� LEAVE BOTTOM EDGE Carl J. CO1S011 - Architect PLLC <br /> ANTIQUE BRONZE ��� � / ��� ��� ��� ��� ��� � <br /> UNATTACHED FOR WATER <br /> INI H. ALL DOOR , 23623 2��1 AVe. W <br /> F S � ,' � RESISTENT BARRIER TO GO <br /> MA CH EV�ER F�I IS�H � �' � � � � PAPER � <br /> UNDERNEATH FLASHING Bothell W 98 <br /> � ; 6�� MIN� 425-806-3703 <br /> DOOR, BASE, &TRIM � ` \� ;�STEP 2: INSTALL JAMB <br /> PAINTING � ` `� \ � � � FLASHING PAPER AT SIDES OF ��wwCarlColsonArchitect.COri1 <br /> ALL DOORS, BASE, <br /> �� �, OPENING, TWO ROWS OF <br /> DOOR&WINDOW �� �� � � � C0111111eYCla.l & ReSldelltla. <br /> TRIM TO BE PRIMED & �, � � STAPLES DO NOT STAPLE <br /> BELOW ROW OF STAPLES AT AYC�11teCtUYe <br /> PAINTED W/ ENAMEL , � � � � <br /> �, s° MIN SILL FLASHING PAPER <br /> PAINT-COLOR � <br /> SELECTION BY <br /> OWNER PTD. SOLID CORE WD. PTD. SOLID CORE WD. DOOR FIBERGLASS FRENCH DOOR (W/ PTD. METAL DOOR W/ PTD. SOLID CORE WD. 16'x 7'OVERHEAD CARRIAGE SYTLE INSULATED 8'x 7'OVERHEAD CARRIAGE SYTLE IN LEAVE BOTTOM EDGE <br /> W LAZING& W/CLOSER SECURITY LOCK DBL. SAFETY GLASS& MINI-BLINDS SECURITY LOCK, DOOR W/PRIVACY METAL GARAGE DOOR W/AUTOMATIC CLOSER. ,,JY • � , ; � METAL GARAGE DOOR W/AUTOMATIC CLOSER. '�� UNATTACHED FOR WATER 3313 O ake s Ave. <br /> DOOR /G , � <br /> C L O S E R, S E C U R I T Y L O C K &W E A T H E R S T R I P P I N G. S E E B E T W E E N G L A S S)S E C U R I T Y L O C K, D E A D B O L T, & L O C K @ B E D R O O M S E E B I D I N F O F O R T Y P E S E E B I D I N F O F O R T Y P E , <br /> &WEATHERSTRIPPING. PLAN &SCHEDULE FOR SIZE DEADBOLT, &WEATHERSTRIPPING. WEATHERSTRIPPING. SEE PLAN &SCHEDULE V � I,,(r��S� V"' V',7 - 1 2" M A X. � R E S I S T E N T B A R R I E R T O G O <br /> IN UNDERNEATH FLASHING Apartments <br /> SEE PLAN &SCHEDULE &SWING SEE PLAN&SCHEDULE FOR SIZE& SEE PLAN&SCHEDULE FOR SIZE&SW G , <br /> FOR SIZE&SWING SWING FOR SIZE&SWING �a -�•: PAPER Pro�ect Address <br /> WINDOW TYPE LEGEND NOTE: FLASHING PAPER TO 3313 Oakes Ave. <br /> HORIZ. SLIDER � � BE COATED VAPOR BARRIER, Everett, WA 98206 <br /> SINGLE HUNG ALL WINDOWS SHALL HAVE A U-VALUE OF 0.28 TO MEET ENERGY CODE REQUIREMENTS / <br /> B C D E F G H I 12��MAx. REINFORCED, GRADE A OR B. <br /> � A � � <br /> _ _ � � � �r —STEP 3: INSTALL �, - <br /> ' N N r "NAIL-ON" WINDOW <br /> r T I <br /> i I �y N N T r T 3' - 11 1/2" � I � <br /> � -l�1 r � <br /> I T T � <br /> ' T T T T• � i � `�' / / I \ Pro'ect Client <br /> � 4016 HOR. SLIDER � � <br /> r T � � ��� � \ � Rainier Building Corp. <br /> � � i � � � P.O. Box 1947 <br /> � _ 2' - 5" 1' - 11" I � ' � / // E�-erett, W1-� 98206 <br /> i / <br /> 2' - 5" 2' - 3" I � � // \ <br /> j 2' - 11" 2' - 5" � 2640 SINGLE HUNG 2040 SINGLE HUNG Sheet Title <br /> I <br /> � � � <br /> � � � � 2646 SINGLE HUNG 2446 SINGLE HUNG <br /> 2' - 11" ' 2' - 7" 3050 SINGLE HUNG 2650 SINGLE HUNG OBSCURE GLASS @ \ \ � � Window & Door <br /> � � �OME LOCATIONS <br /> � 3060 SINGLE HUNG 2860 SINGLE HUNG \ <br /> �— THESE DIMENSIONS REPRESENT <br /> THE FRAME SIZE FOR WINDOW TYPES.COORDINATE W/WINDOW L 5 OF THESE WINDOWS @ UNIT#3 WILL HAVE OBSCURE GLASS STEP 4: INSTALL HEAD ' Legends & Details . <br /> MANUFACTURER FOR ACTUAL WINDOW FRAME SIZE &ROUGH OPENING DIMENSIONS(TYP @ ALL WINDOWS) DUE TO PRIVACY VIEW ISSUES.SEE UNIT#3 UPPER FLOOR PLAN FOR NOTES FLASHING PAPER OVER TOP <br /> WINDOW FLANGE <br /> WINDOW & DOOR TRIM NOTES WINDOW & DOOR SILL PAN ASSEMBLY <br /> NOTES: AT WINDOW HEAD <br /> 2x4orDc8FRAMING / OVER THE WIiN OW HEADL IT � <br /> INTERIOR TRIM NOTES / / <br /> EXTERIOR TRIM NOTES // / <br /> SHEE7ROCK � / // FLASHING PAPER, AND PLACE Professional Stamti <br /> DOOR&WINDOW EXTERIOR TRIM DOOR&WINDOW INTERIOR TRIM THE WATER RESISTANT <br /> ALL DOOR&WINDOW EXTERIOR TRIM SHALL BE ALL DOOR&WINDOW INTERIOR TRIM SHALL BE / BARRIER OVER THE FLANGE 7543 <br /> PRIMED AND PAINTED CEDAR PRIMED AND PAINTED M <br /> DF SEE WINDOW FLASHING / REGISTERE . <br /> METAL FLASHING @ WINDOW SEE BLOCKING NOTE IN / DIAGRAM FOR FLASHING @ OF THE METAL FLASHING ARCHITECT <br /> , , TRIM HEAD � WINDOW GENERAL NOTES � ExrERioR DOORS a WiNDowS. ���'lG� � <br /> � � � �� COORDINATE FLASHING W/ � . <br /> � , ��$LOPED WEEPAREA JAMSILL GUARD INSTALLATION <br /> � SEE BLOCKING NOTE IN WINDOW <br /> � , A � <br /> �� � GENERAL NOTES \ i SCHEDULED WINDOW ACC PTED�INDUST�RYMENTS& CARL J. COLSON <br /> S ATE OF WASHINGTO <br /> � / 5/4x6 PTD.WD.TRIM @ HEAD \ / OPENING SUBFLOOR STANDARDS <br /> �X� SCHEDULED WINDOW OPENING �X� 1x4 PTD.WD.TRIM @ SIDE �� , <br /> / \ 5/4x4 PTD.WD.TRIM @ SIDE JAMB � � CASING&JAMBS SHEATNING 6" MiN , LAP WATER RESISTANT <br /> Document Set T,y�e: <br /> ; � / \ I BARRIER VERTICALLY 6" � ISSUED FOR PERI�TIT: FEB. 6, 2017 <br /> � / 2x PTD. CEDAR SILL W/SLOPE � � � <br /> ,' � 1-1/2"OVERHANG ON SILL 1x4 PTD.WD.TRIM @ JAMSILL GUARD' � <br /> 5/4x4 PTD.WD.TRIM @ BELOW SILL BELOW SILL G � I Revision Schedule <br /> � � � <br /> WINDOW SILL � � I � � LAP WATER RESISTANT Rev. <br /> WINDOW HEAD WINDOW JAMB INSTALL MEMBRANE FLASHING PER / � � BARRIER HORIZONTALLY # Date Description . <br /> 1, ' —� CEDAR SIDING � APPLICATION DETAIL PRIOR TO AND � � � 2�� MIN <br /> ��, DURING WINDOW INSTALLATION �� I *� ** <br /> � r� BUILDING PAPER V � / , 1 * <br /> CEDAR SIDING VINYL WINDOW-SEE WINDOW �� � � i— SLIP LOWER END OF <br /> �I I I � SCHEDULE FOR TYPE I � <br /> BUILDING PAPER PLYWOOD SHEATHING � � PTD.MDF SILL JAMB FLASHING PAPER <br /> II � � AND SILL FLASHING <br /> I I P�Ywoo�sHEarHiNG , �I � �� ' �' ' � `� � PAPER OVER WATER <br /> �� SEALANT @ JOINT �� i �f �� � if ii <br /> M E T A L F L A S H I N G N B A T T I N S U L A T I O N(R-2 1) � SEALANT&BACKER ROD � � � RESISTANT BARRIER AT <br /> BATT INSULATION(R-21 �� � �� �� �� 2x PRIMED&PAINTED � i THE WINDOW SILL <br /> � � I (1)LAYER OF 1/2"GWB 1 " ��� CEDAR SILL W/SLOPED TOP / � � <br /> (1)LAYER OF 1/2"GWB � <br /> �� � 2— � 5/4 x 4 P A I N T E D C E D A R � � <br /> �� FLASHING MEMBRANE PER 5/4 x 6 PRIMED&PAINTED 2 WOOD TRIM W/DRIP EDGE � i � DRI�WING USE NOTIFICt�TION <br /> CEDAR WOOD TRIM 1 LAYER OF 1/2"GWB � I This set of drawin s is bein issued as a Pro ress oi Permit Set oE <br /> �I APPLICATION DETAIL � �' � 1 � — WEATHER RESISTANT g g g � <br /> �� ��� � FLASHING MEMBRANE PER �� i i I Draryings and is subject to change and adding of addiuonal information <br /> � HEADER PER STRUCTURAL DRAWINGS . �� APPLICATION DETAIL �� BATT INSULATION(R-21) � i %� BARR�ER PER SPEC' & � and drawings as requued b}re��iew of the Building Departmentin the <br /> � � �i � PLYWOOD SHEATHING � % BUILDING CODE <br /> � 5/4 x 6 PRIMED& PAINTED CEDAR �I i � � REQUIREMENTS jurisdiction where this project is located. <br /> DO NOT USE THIS DR.���'ING FOR CONSTRUCTION UNLESS <br /> WOOD TRIM W/DRIP EDGE �� PAINTED MDF CASING&TRIM I I THIS DRAWING HAS A BUILDING DEP�RT�IENT"APPRO�'ED" <br /> ��� <br /> � ' I METAL FLASHING STAi�1P APPLIED BY THE B ILDING DEPARTi�1ENT UPON <br /> O�oa �1 � i r i 1 i � <br /> � I�� � f�,� � � � �, VINYL WINDOW-SEE WINDOW BUILDING PAPER CO�iPLETION OF THE PER�IIT RE`'IEW PROCESS. <br /> VINYL WINDOW-SEE WINDOW � SCHEDULE FOR TYPE ' Do not use this drawing for Bidding ox Estimating Purposes unless <br /> SCHEDULE FOR TYPE PAINTED CEDAR OR � '' authoxized by Client.During Constxuction Phase,the Clients General <br /> LINE OF CEDAR SILL BELOW �--- HARDI-PLANK SIDING FLEXIBLE FLASHING MATERIAL <br /> METAL FLASHING FLEXIBLE WINDOW/DOOR/OPENING FLASHING Contractor(Builder) or Developer shall be responsible for ensuring that all <br /> ` Construction Personnel of the General Contractox and all Subcontractors <br /> SHALL BE GRACE VYCOR V40 WEATHER � are supplied with allA ro ed and most current documents. <br /> BARRIER STRIPS BY W.R. GRACE C0. ' ARCHITECTURAL COPYRIGHT � <br /> WINDOW GENERAL NOTES <br /> ROUGH OPENING GLAZING GLAZING ' GLAZING This sheet of drawings may not be reproduced in an}�form without <br /> MARK' WIDTH HEIGHT TYPE QTY MANUFACTURER MATERIAL AREA THICKNESS TYPE U Value COMMENTS 1. CONTRACTOR SHALL VERIFY ALL WINDOW�UANTITIES AND SIZES BEFORE ORDERING EGRESS WINDOWS prior approval of Carl J.Colson-Architect P11C. <br /> ! 2'- 11" 5'- 11 1/2" Sin le Hun w Grids at Top 12 Not Yet Selected Vinyl 2. ALL WINDOWS SHALL BE VINYL WINDOWS WITH DOUBLE GLAZING(1/2" MIN.AIR SPACE) ALL SLEEPING ROOMS ARE REQUIRED TO HAVE EGRESS WINDOWS.THE WINDOWS SHALL HAVE A These document,the ideas,and designs incorporated herein as an <br /> , A 9 9 <br /> B 2'-7" 5'- 11 1/2" Single Hung w Grids at Top 15 Not Yet Selected Vinyl 3. ALL OPERABLE WINDOWS SHALL HAVE INSECT SCREENS. MINIMUM NET CLEAR OPENABLE AREA OF 5.7 S(�UARE FEET.THE MIN. NET CLEAR OPENABLE HEI instrument of service shall remain the property of Carl J.Colson- <br /> DIMENSION SHALL BE 24"AND THE MIN. NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE 20". ALL Architect PLLC and are solely for the use on this project only.These <br /> C 2' - 11" 4' - 11 1/2" Single Hung w Grids at Top 10 Not Yet Selected Vinyl WINDOW SERIES EXIT WINDOWS SHALL HAVE SILLS NO HIGHER THAN 44"ABOVE THE FINISH FLOOR. files,drawings,ideas,or designs may not be tramsmitted electronically <br /> D 2'-5" 4'- 11 1/2" Single Hung w Grids at Top 4 Not Yet Selected Vinyl � <br /> - w Grids at To 10 Not Yet Selected Vinyl ALL WINDOWS SHALL BE MILGARD VINYL WINDOWS- MONTECITO SERIES WITH LOW-E/CLEAR GLASS WINDOW SUPPLIER SHALL VERIFY ALL EGRESS WINDOWS MEET EGRESS REQUIREMENTS BEFORE «ithout express permission oEArchitect.The}•are not be used b}�the <br /> E 2' -5" 4' 5 1/2" Single Hung p (W/ARGON)OR JELD WEN PREMIUM VINYL WINDOWS.ALL WINDOWS SHALL HAVE A MIN. U VALUE OF ACCEPTING ORDER FROM CONTRACTOR. <br /> client or any othex party or entity on other projects,in who e or part,or <br /> i F �2'-3" 4' -5 1/2" ,Single Hung w Grids at Top 6 Not Yet Selected Vinyl �28 <br /> as an extension to this project except b��agreement in�vriting�vith <br /> G 2' -5" 3' - 11 1/2" Single Hung w Grids at Top 3 Not Yet Selected Vinyl ALL WINDOWS SHALL HAVE SIMULATED DIVIDED-LITE GRIDS(@ GLASS INTERIOR& EXTERIOR BLOCKING AT WINDOWS appropriate Einancial compensation to Carl J.Colson-.lrchitect PLLC. <br /> H 1'- 11" 3'- 11 1/2" Single Hung w Grids at Top 4 Not Ye t Se lec te d Viny l S U R F A C E) PR OVIDE BLOCKING @ EACH END OF WINDOW HEADERS FOR 1 STUD SPACE TO ACT AS BACKING FOR Cop`-right Carl J.Colson-PLLC,201%..�ll rights res�n-ed.O <br /> ' I 3' - 11 1/2" 1' -5 1/2" Horz Slider-HV 1 Not Yet Selected Vinyl 6 SF INSTALLATION OF VALANCES/CURTAIN ROD ASSEMBLIES <br /> Grand total:65 SAFETY GLAZING Project Number <br /> I ALL GLASS LOCATED IN AN AREA WHICH THE 2012 INTERNATIONAL RESIDENTIAL CODE CONSIDERS WINDOW SILLGUARD/FLASHING INSTALLATION 2016-04 <br /> � HAZARDOUS SHALL BE SAFETY GLAZING.THESE INCLUDE: CONTRACTOR SHALL INSTALL ALL WINDOWS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. sheet Issue�ate — <br /> I A.)ALL GLAZING IN DOORS AND GLAZING IN ANY OPENING ADJACENT TO A DOOR WITHIN A 24"ARC OF PRIOR TO INSTALLING WINDOW IN ROUGH OPENING, CONTRACTOR SHALL INSTALL"JAMSILL GUARD" ( 03/28/16 � <br /> ' EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED AVAILABLE AT PELLA NORTHWEST IN BELLEVUE 425-455-5550 OR wwwJAMSILL.COM) WHICH IS A VINYL <br /> EDGE OF THE GLAZING IS LESS THAN 60"ABOVE THE WALKING SURFACE. WINDOW SILL DAM TO PREVENT WATER FROM ENTERING WALL CAVITY(INSTALL PER orawn ey <br /> B.)TUB/SHOWER ENCLOSURES. MANUFACTURERS INSTRUCTIONS). CONTRACTOR SHALL THEN INSTALL WINDOW WRAP FLASHING PER Author Window&Door Legends& Details <br /> WINDOW WRAP DETAIL ON TNIS SHEET.ALL WINDOWS SHALL HAVE METAL DRIP FLASHING INSTALLED Sca�e <br /> OBSCURE GLAZING AT HEAD OF WINDOWS. As indicated <br /> Sheet Plot Date2/6/2017 10:41:16 AM <br /> CONTRACTOR TO REFER TO ELEVATION DRAWINGS FOR WINDOWS THAT MAY HAVE OBSCURE <br /> GLAZING. � vvww.CarlColsonArchitect.com <br />