|
�111�_ � ,
<br /> DOOR TYPE LEGEND
<br /> WINDOW FLASHING INSTALLATION
<br /> �
<br /> A B C D E F G _STEP 1 : INSTALL SILL FLASHING
<br /> _ _ _ — — — /� PAPER AT BOTTOM OF
<br /> E INTERIOR TO DECK GARAGE TO EXTERIOR, INTERIOR OVERHEAD DOOR @ UNIT 1 &2 GARAGE OVERHEAD DOOR @ UNIT 3 GARAGE OPENING, STAPLE ALONG TOP
<br /> DOOR HARDWARE EXTERIOR TO ENTRY HOUSE TO GARAG INTERIOR TO PATIO @ UNIT 3
<br /> EDGE 3/8" FROM TOP OF PAPE
<br /> ALL DOORS TO HAVE
<br /> LEVER STYLE � ONL
<br /> ,
<br /> HARDWARE W/ �❑ �� �' ,' / �/ � ��� ��� ��� ��� ��� ���
<br /> ANTI�UE PEWTER OR � � % � �� LEAVE BOTTOM EDGE Carl J. CO1S011 - Architect PLLC
<br /> ANTIQUE BRONZE ��� � / ��� ��� ��� ��� ��� �
<br /> UNATTACHED FOR WATER
<br /> INI H. ALL DOOR , 23623 2��1 AVe. W
<br /> F S � ,' � RESISTENT BARRIER TO GO
<br /> MA CH EV�ER F�I IS�H � �' � � � � PAPER �
<br /> UNDERNEATH FLASHING Bothell W 98
<br /> � ; 6�� MIN� 425-806-3703
<br /> DOOR, BASE, &TRIM � ` \� ;�STEP 2: INSTALL JAMB
<br /> PAINTING � ` `� \ � � � FLASHING PAPER AT SIDES OF ��wwCarlColsonArchitect.COri1
<br /> ALL DOORS, BASE,
<br /> �� �, OPENING, TWO ROWS OF
<br /> DOOR&WINDOW �� �� � � � C0111111eYCla.l & ReSldelltla.
<br /> TRIM TO BE PRIMED & �, � � STAPLES DO NOT STAPLE
<br /> BELOW ROW OF STAPLES AT AYC�11teCtUYe
<br /> PAINTED W/ ENAMEL , � � � �
<br /> �, s° MIN SILL FLASHING PAPER
<br /> PAINT-COLOR �
<br /> SELECTION BY
<br /> OWNER PTD. SOLID CORE WD. PTD. SOLID CORE WD. DOOR FIBERGLASS FRENCH DOOR (W/ PTD. METAL DOOR W/ PTD. SOLID CORE WD. 16'x 7'OVERHEAD CARRIAGE SYTLE INSULATED 8'x 7'OVERHEAD CARRIAGE SYTLE IN LEAVE BOTTOM EDGE
<br /> W LAZING& W/CLOSER SECURITY LOCK DBL. SAFETY GLASS& MINI-BLINDS SECURITY LOCK, DOOR W/PRIVACY METAL GARAGE DOOR W/AUTOMATIC CLOSER. ,,JY • � , ; � METAL GARAGE DOOR W/AUTOMATIC CLOSER. '�� UNATTACHED FOR WATER 3313 O ake s Ave.
<br /> DOOR /G , �
<br /> C L O S E R, S E C U R I T Y L O C K &W E A T H E R S T R I P P I N G. S E E B E T W E E N G L A S S)S E C U R I T Y L O C K, D E A D B O L T, & L O C K @ B E D R O O M S E E B I D I N F O F O R T Y P E S E E B I D I N F O F O R T Y P E ,
<br /> &WEATHERSTRIPPING. PLAN &SCHEDULE FOR SIZE DEADBOLT, &WEATHERSTRIPPING. WEATHERSTRIPPING. SEE PLAN &SCHEDULE V � I,,(r��S� V"' V',7 - 1 2" M A X. � R E S I S T E N T B A R R I E R T O G O
<br /> IN UNDERNEATH FLASHING Apartments
<br /> SEE PLAN &SCHEDULE &SWING SEE PLAN&SCHEDULE FOR SIZE& SEE PLAN&SCHEDULE FOR SIZE&SW G ,
<br /> FOR SIZE&SWING SWING FOR SIZE&SWING �a -�•: PAPER Pro�ect Address
<br /> WINDOW TYPE LEGEND NOTE: FLASHING PAPER TO 3313 Oakes Ave.
<br /> HORIZ. SLIDER � � BE COATED VAPOR BARRIER, Everett, WA 98206
<br /> SINGLE HUNG ALL WINDOWS SHALL HAVE A U-VALUE OF 0.28 TO MEET ENERGY CODE REQUIREMENTS /
<br /> B C D E F G H I 12��MAx. REINFORCED, GRADE A OR B.
<br /> � A � �
<br /> _ _ � � � �r —STEP 3: INSTALL �, -
<br /> ' N N r "NAIL-ON" WINDOW
<br /> r T I
<br /> i I �y N N T r T 3' - 11 1/2" � I �
<br /> � -l�1 r �
<br /> I T T �
<br /> ' T T T T• � i � `�' / / I \ Pro'ect Client
<br /> � 4016 HOR. SLIDER � �
<br /> r T � � ��� � \ � Rainier Building Corp.
<br /> � � i � � � P.O. Box 1947
<br /> � _ 2' - 5" 1' - 11" I � ' � / // E�-erett, W1-� 98206
<br /> i /
<br /> 2' - 5" 2' - 3" I � � // \
<br /> j 2' - 11" 2' - 5" � 2640 SINGLE HUNG 2040 SINGLE HUNG Sheet Title
<br /> I
<br /> � � �
<br /> � � � � 2646 SINGLE HUNG 2446 SINGLE HUNG
<br /> 2' - 11" ' 2' - 7" 3050 SINGLE HUNG 2650 SINGLE HUNG OBSCURE GLASS @ \ \ � � Window & Door
<br /> � � �OME LOCATIONS
<br /> � 3060 SINGLE HUNG 2860 SINGLE HUNG \
<br /> �— THESE DIMENSIONS REPRESENT
<br /> THE FRAME SIZE FOR WINDOW TYPES.COORDINATE W/WINDOW L 5 OF THESE WINDOWS @ UNIT#3 WILL HAVE OBSCURE GLASS STEP 4: INSTALL HEAD ' Legends & Details .
<br /> MANUFACTURER FOR ACTUAL WINDOW FRAME SIZE &ROUGH OPENING DIMENSIONS(TYP @ ALL WINDOWS) DUE TO PRIVACY VIEW ISSUES.SEE UNIT#3 UPPER FLOOR PLAN FOR NOTES FLASHING PAPER OVER TOP
<br /> WINDOW FLANGE
<br /> WINDOW & DOOR TRIM NOTES WINDOW & DOOR SILL PAN ASSEMBLY
<br /> NOTES: AT WINDOW HEAD
<br /> 2x4orDc8FRAMING / OVER THE WIiN OW HEADL IT �
<br /> INTERIOR TRIM NOTES / /
<br /> EXTERIOR TRIM NOTES // /
<br /> SHEE7ROCK � / // FLASHING PAPER, AND PLACE Professional Stamti
<br /> DOOR&WINDOW EXTERIOR TRIM DOOR&WINDOW INTERIOR TRIM THE WATER RESISTANT
<br /> ALL DOOR&WINDOW EXTERIOR TRIM SHALL BE ALL DOOR&WINDOW INTERIOR TRIM SHALL BE / BARRIER OVER THE FLANGE 7543
<br /> PRIMED AND PAINTED CEDAR PRIMED AND PAINTED M
<br /> DF SEE WINDOW FLASHING / REGISTERE .
<br /> METAL FLASHING @ WINDOW SEE BLOCKING NOTE IN / DIAGRAM FOR FLASHING @ OF THE METAL FLASHING ARCHITECT
<br /> , , TRIM HEAD � WINDOW GENERAL NOTES � ExrERioR DOORS a WiNDowS. ���'lG� �
<br /> � � � �� COORDINATE FLASHING W/ � .
<br /> � , ��$LOPED WEEPAREA JAMSILL GUARD INSTALLATION
<br /> � SEE BLOCKING NOTE IN WINDOW
<br /> � , A �
<br /> �� � GENERAL NOTES \ i SCHEDULED WINDOW ACC PTED�INDUST�RYMENTS& CARL J. COLSON
<br /> S ATE OF WASHINGTO
<br /> � / 5/4x6 PTD.WD.TRIM @ HEAD \ / OPENING SUBFLOOR STANDARDS
<br /> �X� SCHEDULED WINDOW OPENING �X� 1x4 PTD.WD.TRIM @ SIDE �� ,
<br /> / \ 5/4x4 PTD.WD.TRIM @ SIDE JAMB � � CASING&JAMBS SHEATNING 6" MiN , LAP WATER RESISTANT
<br /> Document Set T,y�e:
<br /> ; � / \ I BARRIER VERTICALLY 6" � ISSUED FOR PERI�TIT: FEB. 6, 2017
<br /> � / 2x PTD. CEDAR SILL W/SLOPE � � �
<br /> ,' � 1-1/2"OVERHANG ON SILL 1x4 PTD.WD.TRIM @ JAMSILL GUARD' �
<br /> 5/4x4 PTD.WD.TRIM @ BELOW SILL BELOW SILL G � I Revision Schedule
<br /> � � �
<br /> WINDOW SILL � � I � � LAP WATER RESISTANT Rev.
<br /> WINDOW HEAD WINDOW JAMB INSTALL MEMBRANE FLASHING PER / � � BARRIER HORIZONTALLY # Date Description .
<br /> 1, ' —� CEDAR SIDING � APPLICATION DETAIL PRIOR TO AND � � � 2�� MIN
<br /> ��, DURING WINDOW INSTALLATION �� I *� **
<br /> � r� BUILDING PAPER V � / , 1 *
<br /> CEDAR SIDING VINYL WINDOW-SEE WINDOW �� � � i— SLIP LOWER END OF
<br /> �I I I � SCHEDULE FOR TYPE I �
<br /> BUILDING PAPER PLYWOOD SHEATHING � � PTD.MDF SILL JAMB FLASHING PAPER
<br /> II � � AND SILL FLASHING
<br /> I I P�Ywoo�sHEarHiNG , �I � �� ' �' ' � `� � PAPER OVER WATER
<br /> �� SEALANT @ JOINT �� i �f �� � if ii
<br /> M E T A L F L A S H I N G N B A T T I N S U L A T I O N(R-2 1) � SEALANT&BACKER ROD � � � RESISTANT BARRIER AT
<br /> BATT INSULATION(R-21 �� � �� �� �� 2x PRIMED&PAINTED � i THE WINDOW SILL
<br /> � � I (1)LAYER OF 1/2"GWB 1 " ��� CEDAR SILL W/SLOPED TOP / � �
<br /> (1)LAYER OF 1/2"GWB �
<br /> �� � 2— � 5/4 x 4 P A I N T E D C E D A R � �
<br /> �� FLASHING MEMBRANE PER 5/4 x 6 PRIMED&PAINTED 2 WOOD TRIM W/DRIP EDGE � i � DRI�WING USE NOTIFICt�TION
<br /> CEDAR WOOD TRIM 1 LAYER OF 1/2"GWB � I This set of drawin s is bein issued as a Pro ress oi Permit Set oE
<br /> �I APPLICATION DETAIL � �' � 1 � — WEATHER RESISTANT g g g �
<br /> �� ��� � FLASHING MEMBRANE PER �� i i I Draryings and is subject to change and adding of addiuonal information
<br /> � HEADER PER STRUCTURAL DRAWINGS . �� APPLICATION DETAIL �� BATT INSULATION(R-21) � i %� BARR�ER PER SPEC' & � and drawings as requued b}re��iew of the Building Departmentin the
<br /> � � �i � PLYWOOD SHEATHING � % BUILDING CODE
<br /> � 5/4 x 6 PRIMED& PAINTED CEDAR �I i � � REQUIREMENTS jurisdiction where this project is located.
<br /> DO NOT USE THIS DR.���'ING FOR CONSTRUCTION UNLESS
<br /> WOOD TRIM W/DRIP EDGE �� PAINTED MDF CASING&TRIM I I THIS DRAWING HAS A BUILDING DEP�RT�IENT"APPRO�'ED"
<br /> ���
<br /> � ' I METAL FLASHING STAi�1P APPLIED BY THE B ILDING DEPARTi�1ENT UPON
<br /> O�oa �1 � i r i 1 i �
<br /> � I�� � f�,� � � � �, VINYL WINDOW-SEE WINDOW BUILDING PAPER CO�iPLETION OF THE PER�IIT RE`'IEW PROCESS.
<br /> VINYL WINDOW-SEE WINDOW � SCHEDULE FOR TYPE ' Do not use this drawing for Bidding ox Estimating Purposes unless
<br /> SCHEDULE FOR TYPE PAINTED CEDAR OR � '' authoxized by Client.During Constxuction Phase,the Clients General
<br /> LINE OF CEDAR SILL BELOW �--- HARDI-PLANK SIDING FLEXIBLE FLASHING MATERIAL
<br /> METAL FLASHING FLEXIBLE WINDOW/DOOR/OPENING FLASHING Contractor(Builder) or Developer shall be responsible for ensuring that all
<br /> ` Construction Personnel of the General Contractox and all Subcontractors
<br /> SHALL BE GRACE VYCOR V40 WEATHER � are supplied with allA ro ed and most current documents.
<br /> BARRIER STRIPS BY W.R. GRACE C0. ' ARCHITECTURAL COPYRIGHT �
<br /> WINDOW GENERAL NOTES
<br /> ROUGH OPENING GLAZING GLAZING ' GLAZING This sheet of drawings may not be reproduced in an}�form without
<br /> MARK' WIDTH HEIGHT TYPE QTY MANUFACTURER MATERIAL AREA THICKNESS TYPE U Value COMMENTS 1. CONTRACTOR SHALL VERIFY ALL WINDOW�UANTITIES AND SIZES BEFORE ORDERING EGRESS WINDOWS prior approval of Carl J.Colson-Architect P11C.
<br /> ! 2'- 11" 5'- 11 1/2" Sin le Hun w Grids at Top 12 Not Yet Selected Vinyl 2. ALL WINDOWS SHALL BE VINYL WINDOWS WITH DOUBLE GLAZING(1/2" MIN.AIR SPACE) ALL SLEEPING ROOMS ARE REQUIRED TO HAVE EGRESS WINDOWS.THE WINDOWS SHALL HAVE A These document,the ideas,and designs incorporated herein as an
<br /> , A 9 9
<br /> B 2'-7" 5'- 11 1/2" Single Hung w Grids at Top 15 Not Yet Selected Vinyl 3. ALL OPERABLE WINDOWS SHALL HAVE INSECT SCREENS. MINIMUM NET CLEAR OPENABLE AREA OF 5.7 S(�UARE FEET.THE MIN. NET CLEAR OPENABLE HEI instrument of service shall remain the property of Carl J.Colson-
<br /> DIMENSION SHALL BE 24"AND THE MIN. NET CLEAR OPENABLE WIDTH DIMENSION SHALL BE 20". ALL Architect PLLC and are solely for the use on this project only.These
<br /> C 2' - 11" 4' - 11 1/2" Single Hung w Grids at Top 10 Not Yet Selected Vinyl WINDOW SERIES EXIT WINDOWS SHALL HAVE SILLS NO HIGHER THAN 44"ABOVE THE FINISH FLOOR. files,drawings,ideas,or designs may not be tramsmitted electronically
<br /> D 2'-5" 4'- 11 1/2" Single Hung w Grids at Top 4 Not Yet Selected Vinyl �
<br /> - w Grids at To 10 Not Yet Selected Vinyl ALL WINDOWS SHALL BE MILGARD VINYL WINDOWS- MONTECITO SERIES WITH LOW-E/CLEAR GLASS WINDOW SUPPLIER SHALL VERIFY ALL EGRESS WINDOWS MEET EGRESS REQUIREMENTS BEFORE «ithout express permission oEArchitect.The}•are not be used b}�the
<br /> E 2' -5" 4' 5 1/2" Single Hung p (W/ARGON)OR JELD WEN PREMIUM VINYL WINDOWS.ALL WINDOWS SHALL HAVE A MIN. U VALUE OF ACCEPTING ORDER FROM CONTRACTOR.
<br /> client or any othex party or entity on other projects,in who e or part,or
<br /> i F �2'-3" 4' -5 1/2" ,Single Hung w Grids at Top 6 Not Yet Selected Vinyl �28
<br /> as an extension to this project except b��agreement in�vriting�vith
<br /> G 2' -5" 3' - 11 1/2" Single Hung w Grids at Top 3 Not Yet Selected Vinyl ALL WINDOWS SHALL HAVE SIMULATED DIVIDED-LITE GRIDS(@ GLASS INTERIOR& EXTERIOR BLOCKING AT WINDOWS appropriate Einancial compensation to Carl J.Colson-.lrchitect PLLC.
<br /> H 1'- 11" 3'- 11 1/2" Single Hung w Grids at Top 4 Not Ye t Se lec te d Viny l S U R F A C E) PR OVIDE BLOCKING @ EACH END OF WINDOW HEADERS FOR 1 STUD SPACE TO ACT AS BACKING FOR Cop`-right Carl J.Colson-PLLC,201%..�ll rights res�n-ed.O
<br /> ' I 3' - 11 1/2" 1' -5 1/2" Horz Slider-HV 1 Not Yet Selected Vinyl 6 SF INSTALLATION OF VALANCES/CURTAIN ROD ASSEMBLIES
<br /> Grand total:65 SAFETY GLAZING Project Number
<br /> I ALL GLASS LOCATED IN AN AREA WHICH THE 2012 INTERNATIONAL RESIDENTIAL CODE CONSIDERS WINDOW SILLGUARD/FLASHING INSTALLATION 2016-04
<br /> � HAZARDOUS SHALL BE SAFETY GLAZING.THESE INCLUDE: CONTRACTOR SHALL INSTALL ALL WINDOWS PER MANUFACTURERS INSTALLATION INSTRUCTIONS. sheet Issue�ate —
<br /> I A.)ALL GLAZING IN DOORS AND GLAZING IN ANY OPENING ADJACENT TO A DOOR WITHIN A 24"ARC OF PRIOR TO INSTALLING WINDOW IN ROUGH OPENING, CONTRACTOR SHALL INSTALL"JAMSILL GUARD" ( 03/28/16 �
<br /> ' EITHER VERTICAL EDGE OF THE DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM EXPOSED AVAILABLE AT PELLA NORTHWEST IN BELLEVUE 425-455-5550 OR wwwJAMSILL.COM) WHICH IS A VINYL
<br /> EDGE OF THE GLAZING IS LESS THAN 60"ABOVE THE WALKING SURFACE. WINDOW SILL DAM TO PREVENT WATER FROM ENTERING WALL CAVITY(INSTALL PER orawn ey
<br /> B.)TUB/SHOWER ENCLOSURES. MANUFACTURERS INSTRUCTIONS). CONTRACTOR SHALL THEN INSTALL WINDOW WRAP FLASHING PER Author Window&Door Legends& Details
<br /> WINDOW WRAP DETAIL ON TNIS SHEET.ALL WINDOWS SHALL HAVE METAL DRIP FLASHING INSTALLED Sca�e
<br /> OBSCURE GLAZING AT HEAD OF WINDOWS. As indicated
<br /> Sheet Plot Date2/6/2017 10:41:16 AM
<br /> CONTRACTOR TO REFER TO ELEVATION DRAWINGS FOR WINDOWS THAT MAY HAVE OBSCURE
<br /> GLAZING. � vvww.CarlColsonArchitect.com
<br />
|