Laserfiche WebLink
, _� .. _ _ : _ _ . _ ___ ____ _ ___ __ _ _ _ __ _ _ ___ _ _ ___ _ _ <br /> �yn-.�.__ __ ___. <br /> GENERAL NOTES FIRE SAFETY ISSUES CASEWORK, PRESSURE TREATED WOOD, & FINISHES <br /> 1. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES THAT EXIST WITHIN THE 1. FIRE BLOCKING SHALL BE REQUIRED AT ALL LOCATIONS REQUIRED BY THE 2015 1. ALL PAINT AND LIKE FINISHES SHALL BE APPLIED IN ACCORDANCE WITH THE <br /> DRAWINGS. INTERNATIONAL RESIDENTIAL BUILDING CODE. MANUFACTURER'S RECOMMENDATIONS. <br /> 2. ALL METHODS, MATERIALS, AND WORKMANSHIP SHALL CONFORM TO THE 2015 2. ALL BEDROOMS SHALL HAVE WINDOWS THAT COMPLY WITH 2O15 INTERNATIONAL 2. CARPET CONTRACTOR SHALL FURNISH AND INSTALL RUBBER REDUCER STRIPS AT ALL <br /> INTERNATIONAL RESIDENTIAL BUILDING CODE. RESIDENTIAL BUILDING CODE EGRESS REQUIREMENTS. REFER TO WINDOW SCHEDULE LOCATIONS WHERE CARPET AND RESILIENT FLOORING MEET. PROVIDE COLOR SAMPLES TO <br /> 3. THE CONTRACTOR SHALL INDEMNIFY AND HOLD CARL J. COLSON - ARCHITECT FOR ALL WINDOW SIZES AND EGRESS REQUIREMENTS. OWNER FOR APPROVAL. <br /> PLLC AND THEIR CONSULTANTS HARMLESS FOR INJURY OR DEATH TO PERSONS OR 3. ALL NEW BEDROOMS (AND AREAS ADJACENT TO BEDROOM ENTRY) SHALL HAVE 3. PREPARE FLOOR PER FLOORING AND CARPET MANUFACTURERS RECOMMENDATIONS TO <br /> FOR DAMAGE TO PROPERTY CAUSED BY THE CONTRACTOR, HIS AGENTS, SMOKE DETECTORS (W/ BATTERY BACKUP) HARDWIRED INTO THE ELECTRICAL SYSTEM. PROVIDE LEVEL AREA FOR FLOORING INSTALLATION AND LEVEL FLOORING TRANSITIONS. . <br /> EMPLOYEES OR SUBCONTRACTORS. 4. OCCUPANCY SEPARATION WALLS ARE REQUIRED IN THIS PROJECT BETWEEN THE 4. ALL FLOORING MATERIALS TO BE LIGHT WEIGHT. CERAMIC TILE SHALL BE THIN-SET TYPE. Carl J. Colsori - Architect PLLC <br /> 4. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ADJACENT WORK LIVING SPACE AND ATTACHED GARAGE AT EACH RESIDENTIAL UNIT. <br /> AND SHALL REPAIR SAID DAMAGE AT HIS OWN EXPENSE. 5. NO AREA SEPARATION WALLS ARE REQUIRED IN THIS PROJECT. CASEWORK & MILLWORK 23623 ZOth Ave. � <br /> 5. ANY WORK INSTALLED IN CONFLICT WITH THESE DRAWINGS SHALL BE CORRECTED 6. CONSTRUCTION TYPE: TYPE V-B. CONTRACTOR NOTE: THE FLOOR PLANS SHOW KITCHEN AND BATH CABINETS IN FLOOR PLANS Bothell WA 98021 <br /> BY THE SUBCONTRACTOR AT NO EXPENSE TO THE OWNER OR CARL J. COLSON - 7. ADDRESSES SHALL BE POSTED ON THE BUILDING AS REQUIRED BY THE WOODINVILLE ONLY. CONTRACTOR SHALL COORDINATE SELECTION OF CABINET MANUFACTURER AND TYPE � <br /> ARCHITECT PLLC. CODE / 2015 IRC AND APPLICABLE FIRE SAFETY CODE. WITH HOME OWNER. 42S-SO6-3703 <br /> 6. ONLY APPROVED "PERMIT SET" MARKED DRAWINGS INCORPORATING ALL ADDENDA 8. ALL REQUIRED FIRE RATED DOORS SHALL BEAR A LABEL FROM A RECOGNIZED 1. ALL MILLWORK (WOODWORK AND CABINETRY) SPECIFIED ON THESE DRAWINGS SHALL BE <br /> AND DIMENSIONAL CLARIFICATIONS SHALL BE USED DURING THE EXECUTtON OF THE AGENCY. FURNISHED AND INSTALLED BY THE MILLWORK CONTRACTOR UNLESS NOTED OTHERWISE. WWWCaYlCOlS011ArC�1lteCt.COrT1 <br /> WORK. 2. THE MILLWORK CONTRACTOR SHALL BE RESPONSIBLE FOR APPLYING FINISHES FOR ALL Commercial & Residential <br /> 7. ALL PRODUCTS AND MATERIALS SPECIFIED IN THE DRAWINGS (W/ EXCEPTION OF MOISTURE CONTROL MILLWORK IN HIS SHOP. DO NOT APPLY FINISH COATS IN FIELD. <br /> SPECIFIC FINISH COLORS AND FLOORING) ARE INTENDED TO BE ON AN "OR EQUAL" 3. ALL MATERIALS AND WORKMANSHIP MUST BE EQUAL IN ALL RESPECTS TO THE STANDARDS Architecture <br /> BASIS. ANY PROPOSED SUBSTITUTIONS MUST BE SUBMITTED TO CARL J. C�OLSON - 1. ALL INTERIOR FACE OF EXTERIOR WALLS AND CEILINGS SHALL BE PAINTED WITH A SET FORTH IN THE ARCHITECTURAL WOODWORKING INSTITUTE (A.W.I.). MOST CURRENT EDITION <br /> ARCHITECT PLLC OR OWNER IN WRITING FOR APPROVAL WITHOUT DELAY OF P.V.A. PAINT TO MINIMIZE MOISTURE PENETRATION OF EXTERIOR WALLS OR CEILING PUBLISHED BY THE A.W.I. AND THE STANDARDS SET BY THE OWNER / CONTRACTOR. <br /> SCHEDULE. INSULATION SPACE, 4. PLYWOOD SHALL PER THE GRADE AND TRADEMARK IDENTIFICATION OF THE AMERICAN 3313 Oakes Ave. <br /> 8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATIONS AND COORDINATION OF 2. WALLS: INSERT STAPLED BATTS WITH A PERM RATING EQUAL TO OR LESS THAN 1 .0 MAY PLYWOOD ASSOCIATION (APA). <br /> SUBCONTRACTORS' WORK TO SECURE COMPLIANCE WITH DRAWINGS AND BE INSTALLED IF STAPLES ARE PLACED MAXIMUM 8" O.C. AND GAPS BETWEEN THE 5. PARTICLEBOARD BACKING SHALL BE PERMITTED IN AREAS OF THE CASEWORK THAT ARE NOT <br /> SPECIFICATIONS. THIS INCLUDES THE ACCURATE LOCATION OF STRUCTURAL FACING AND FRAMING DO NOT EXCEED 1/16". VISIBLE. ApiLrtmentS <br /> MEMBERS AND OPENINGS FOR MECHANICAL, ELECTRICAL, STAIRS, AND 3. THE FOLLOWING OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, 6. PROVIDE CUT-OUTS IN MILLWORK AS REQUIRED FOR ALL ELECTRICAL ITEMS. VERIFY ALL Project r�ddress <br /> MISCELLANEOUS EQUIPMENT. GASKETED, OR WEATHERSTRIPPED TO LIMIT AIR LEAKAGE: EXTERIOR JOINTS AROUND REQUIREMENTS PRIOR TO FABRICATION. <br /> 9. AT COMPLETION OF THE WORK, REMOVE ALL DEBRIS FROM THE SITE, LEAVING THE WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATION, BETWEEN 7. FIT AND SECURE CABINET HARDWARE PER MANUFACTURER'S PRINTED INSTRUCTIONS. 3313 OakeS AVe. . <br /> BUILDING CLEAN. ALL WINDOWS AND GLASS SHALL BE WASHED, ALL CARPETS SHALL WALLS AND ROOF AND BETWEEN WALL PANELS: OPENINGS AT PENETRATIONS OF UTILITY EXERCISE CAUTION NOT TO INJURE OR MAR SURFACES. REPAIR ANY AND ALL DAMAGED EVeYett, WA 98206 � <br /> BE CLEANED (AS NECESSARY) AND VACUUMED. ALL FLOORS SHALL BE CLEANED AND SERVICES THROUGH WALLS, FLOORS, AND ROOF. SURFACES TO LIKE-NEW CONDITION. <br /> SWEPT. CONTRACTOR SHALL REPAIR OR REPLACE ANY DAMAGED ITEMS PRIOR TO 4. ALL EXTERIOR WINDOWS SHALL BE DESIGNED TO LIMIT AIR LEAKAGE INTO OR FROM THE 8. ALL MILLWORK ELECTRICAL MATERIAL, WORKMANSHIP, AND INSTALLATIONS SHALL BE IN <br /> FINAL INSPECTION. BUILDING ENVELOPE. MANUFACTURED WINDOWS SHALL HAVE AIR INFILTRATION RATES NO CONFORMANCE WITH APPLICABLE LOCAL, STATE, AND NATIONAL ORDINANCES AND CODES. ALL � <br /> GREATER THAN 0.5 CFM. MATERIAL AND FIXTURES TO BE U.L. APPROVED. <br /> BUILDING CODE NOTES 9. THE GENERAL CONTRACTOR SHALL FURNISH ALL NECESSARY WOOD BLOCKING FOR A <br /> ELECTRICAL / MECHANICAL/ PLUMBING COMPLETE AND SECURE iNSTALLATION. <br /> 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN <br /> ACCORDANCE WITH THE APPLICABLE SAFETY CODES. 1. HEATING WILL BE PROVIDED BY A GAS FIRED FORCED AIR FURNACE TO BE LOCATED IN WATERPROOFING CONSTRUCTION NOTES Pro�ect Client <br /> 2. THE CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY PERMITS AND FEES. GARAGE. HOT WATER WILL BE PROVIDED BY A GAS FIRED WATER HEATER LOCATED IN THIS ENTIRE SET OF ARCHITECTURAL DRAWINGS IS PREPARED AS A PERMIT SET OF DRAWINGS Rainier Building Corp. <br /> 3. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE DESIGN-BUILD AND SHALL BE GARAGE. GENERAL CONTRACTOR AND MECHANICAL SUBCONTRACTOR SHALL REVIEW ONLY FOR THE OWNER AND BUILDER FOR THIS PROJECT ONLY. ALL DETAILS AND DRAWINGS P.O. Box 1947 <br /> UNDER SEPARATE PERMITS TO BE OBTAINED BY THE CONTRACTOR. FURNACE AND WATER HEATER LOCATION AND DETERMINE ROUTE FOR EXHAUST FLUE SHOWN ARE FOR PERMIT PURPOSES ONLY AND DO NOT CONSTITUTE THE FULL SET OF DETAILS <br /> 4. ALL WORK SHALL CONFORM TO THE APPLICABLE BUILDING CODES AND PRIOR TO FRAMING OF BUILDING. MECHANICAL SUBCONTRACTOR TO PROVIDE HEATING REQUIRED TO CONSTRUCT THIS PROJECT. THE BUILDER SHALL BE RESPONSIBLE FOR E�-erett, WA 98206 <br /> ORDINANCES. IN CASE OF ANY CONFLICT WHERE THE METHODS OR STANDARDS OF LOAD CALCULATIONS TO APPLICABLE BUILDING DEPARTMENT FOR APPROVAL AND DEVELOPING CONSTRUCTION DETAILS NECESSARY TO CONSTRUCT A WEATHERTIGHT, DURABLE Sheet Title <br /> INSTALLATION OF THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE PERMIT PRIOR TO CONSTRUCTION. GENERAL CONTRACTOR AND MECHANtCAL BUILDING. . <br /> REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL SUBCONTRACTOR SHALL REVIEW ALL DRAWINGS PRIOR TO CONSTRUCTION TO BEST ALL FLASHING, WEATHERPROOFING, ROOFING, AND WATERPROOFING DETAILS AND General Notes <br /> GOVERN. NOTIFY THE ARCHITECT OF ANY AND ALL CONFLICTS IN WRITING. DETERMINE ROUTING OF ALL NEW DUCTWORK AND VENT LOCATIONS. CONSTRUCTION OF THESE DETAIL ASSEMBLIES ARE THE FULL AND COMPLETE RESPONSIBILITY <br /> 5. THE CONTRACTOR SHALL PROVIDE TEMPORARY FACILITIES AS REQUIRED BY 2. WATER FLOW LIMITING DEVICES SHALL BE PROVIDED AT LAVATORIES (0.5 GPM) AND AT OF THE BUILDER, AND THESE DETAILS SHALL BE CONSTRUCTED PER MANUFACTURER <br /> CODE. SHOWERS (3 GPM). REQUIREMENTS, BUILDING CODE REQUIREMENTS, AND ACCEPTED INDUSTRY STANDARDS FOR <br /> 3. PROVIDE LAUNDRY ROOM WITH MECHANICAL VENTILATING SYSTEMS AS SHOWN (5 AIR PERFORMANCE. <br /> DIMENSIONS AND FRAMING NOTES CHANGES PER HOUR PER WASHINGTON STATE ENERGY CODE). <br /> 4. ALL SOLDER USED IN PLUMBING CONNECTIONS, SHALL BE LEAD FREE AS DEFINED BY THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A WEATHERTIGHT . <br /> 1. ALL DIMENSIONS SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS WAC STANDARDS 51-16-060. BUILDING INCLUDING ALL NECESSARY SEALANT AND FLASHINGS IN ACCORDANCE WITH <br /> ARE GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF 5. ALL ELECTRICAL TRIM TO BE WHITE (I.E., SWITCHES, OUTLETS, ETC.) INDUSTRY STANDARDS, WHETHER DETAILED SPECIFICALLY IN THESE DRAWINGS OR NOT. <br /> ACCURACY. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND 6. CLOTHES DRYER MOISTURE EXHAUST VENTS SHALL COMPLY WITH MANUFACTURER'S <br /> DIMENSIONS AND SHALL NOTIFY CARL J. COLSON - ARCHITECT PLLC OF ANY REQUIREMENTS FOR MAXIMUM HORIZONTAL AND VERTICAL LENGTHS AND AS PER 1. EXTERIOR DOORS, WINDOWS, VENTS, CORRIDOR OPENINGS: Professional Stamti <br /> DISCREPANCIES OR CONDITIONS ADVERSELY AFFECTING THE DESIGN PRIOR TO UNIFORM MECHANICAL CODE. THE CONTRACTOR SHALL SEAL AROUND ALL EXTERIOR WINDOWS, DOORS, VENTS AND OTHER � <br /> PROCEEDING WITH THE WORK. 7. ALL INTERIOR PLUMBING WALLS SHALL BE INSULATED FOR SOUND CONTROL. SUCH PENETRATIONS WITH A CONTINUOUS BEAD OF CAULKING TO PROVIDE FOR A WEATHER- 7543 REGISTERE <br /> 2. DO NOT SCALE THE DRAWINGS. CONTRACTOR MUST VERIFY ALL D�MENSIONS AND TIGHT STRUCTURE. iN ADDITION, ALL EXTERIOR OPENINGS (WINDOWS, DOORS, VENTS, ARCHITECT <br /> FIELD CONDITIONS PRIOR TO COMMENCING THE WORK. THE CONTRACTOR SHALL MATERIALS CORRIDOR OPENINGS) SHALL BE FLASHED WITH A FLASHING MEMBRANE AS SHOWN ON THE L�� ,rJ __ <br /> USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENTS. SEE NOTE SECTION "MOLD CONTROL" FOR INFORMATION ON GYPSUM BOARD PRODUCTS. WINDOW DETAIL SHEET. USE METAL HEAD FLASHING ABOVE ALL EXTERIOR DOORS AND ;�' � <br /> NOTIFY CARL J. COLSON - ARCHITECT PLLC IF ANY DISCREPANCIES ARE FOUND. 1. SHOWER /TUB UNITS SHALL BE AS SPECIFIED ON DRAWINGS. COORDINATE THIS ITEM WINDOWS. FURNISH AND INSTALL FLASHINGS IN ACCORDANCE WITH SMACNA STANDARDS. caR� �. co�sorv <br /> 3. ALL INTERIOR FRAMED WALL DIMENSIONS ARE SHOWN TO FACE OF STUD, UNLESS PRIOR TO PROVIDING BID PRICE. 2. SEE SHEET A-4.1 CONSTRUCTION ASSEMBLY NOTES FOR INFORMATION ON BASEMENT WALL S ATE OF WASHINGTO <br /> NOTED OTHERWISE. DIMENSIONS TO THE EXTERIOR SIDE OF WOOD FRAMED WALLS 2. ALL GYPSUM WALLBOARD IN BATHROOMS SHALL BE WATER RESISTANT. WATERPROOFING. <br /> ARE TO THE FACE OF STUD. 3. ALL WEATHER EXPOSED SURFACES SHALL HAVE A WEATHER-RESISTANT BARRIER <br /> 4. OFFSET STUDS WHERE REQUIRED TO MAKE STRAIGHT AND CONTINUOUS WALL (SEE SHEET A-4.1) INSTALLED BEHIND EXTERIOR SIDING TO PROTECT INTERIOR WALL PRESSURE TREATED WOOD / STRUCTURAL FASTENERS Documcnt Set T�e: <br /> PLANES, ESPECIALLY AT FLOOR OPENINGS. ALL PARTITIONS AND WALLS SHALL MATERIALS. SEE SECTION DRAWINGS FOR ADDITIONAL INFORMATION. EFFECTIVE DEC. 31 , 2003, THE PRESSURE TREATED WOOD INDUSTRY VOLUNTARILY ISSUED FOR PERl�1IT: FEB. 6, 2017 <br /> EXTEND FULL HEIGHT TO STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. 4. WOOD SUPPORTS IN CONTACT WITH SOIL OR MASONRY OR LOCATED NEARER THAN 6" TRANSITIONED FROM CHROMATED COPPER ARSENATE (CCA-C) USED IN RESIDENTIAL <br /> 5. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR TO SOIL SHALL BE PRESSURE TREATED WOOD. SEE NOTES FOR PRESSURE TREATED CONSTRUCTION TO ALTERNATIVE TREATMENTS. ANY PRESSURE TREATED WOOD SPECIFIED FOR -- <br /> MECHANICAL AND ELECTRICAL EQUIPMENT WITH THE RESPECTIVE WOOD AND FASTENERS REQUIREMENTS ON THIS PAGE. THIS PROJECT SHALL NOT CONTAIN CCA-C IN THE PRESERVATIVE PROCESS. Revision Schedule <br /> SUBCONTRACTORS PRIOR TO CONSTRUCTION. 5. GYPSUM WALLBOARD SHALL NOT BE INSTALLED UNTIL WEATHER PROTECTION IS ACCORDING TO SIMPSON STRONGTIES WEBSITE, "TESTING HAS SHOWN THAT CERTAIN Rev. <br /> 6. THE CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSIONS FOR EQUIPMENT, INSTALLED. REPLACEMENT ALTERNATIVE TREATMENTS ARE GENERALLY MORE CORROSIVE THAN CCA-C". AS � # Date Description <br /> DOORS, AND WINDOWS. 6. WHEN INSTALLED DIRECTLY ON FRAMING, ALL EDGES AND ENDS OF GYPSUM A RESULT OF THESE ALTERNATIVE METHODS OF TREATMENT, THE NON CCA-C TREATED WOOD IS <br /> 7. ALL DOORS NOT LOCATED BY DIMENSIONS ON PLANS, INTERIOR ELEVATIONS, OR WALLBOARD SHALL OCCUR ON THE FRAMING MEMBERS, EXCEPT THOSE EDGES WHICH MORE CORROSIVE TO METAL HANGERS AND FASTENERS. REFER TO SIMPSON STRUCTURAL �� ** <br /> DETAILS SHALL BE 5" FROM FACE OF STUD TO EDGE OF DOOR OPENING. ARE PERPENDICULAR TO THE FRAMING. HANGERS WEBSITE FOR TECHNICAL BULLETIN. (wwwSTRONGTIE.COM (SIMPSON'S WEBSITE), GO ' 1 * <br /> 8. FINISH FLOOR ELEVATION REFERS TO TOP OF CONCRETE SLAB OR TOP OF 7. ALL FLOORING MATERIAL (CARPET, TILE, VINYL), WALL TILE, AND PAINT FINISHES SHALL TO "CORROSION INFORMATION" THEN "PRESSURE TREATED WOOD TECH BULLETIN". ) . REFER <br /> PLYWOOD FLOOR DECK. BE SELECTED BY HOME OWNER. CONTRACTOR SHALL COORDINATE SELECTION OF THESE TO SIMPSON'S WEBPAGE "wwwSTRONGTIE.COM/PRODUCTUSE/SELECTION-GUIDE.HTML" FOR <br /> 9. REPETITIVE FEATURES ARE OFTEN DRAWN ONLY ONCE AND SHALL BE ITEMS WITH HOME OWNER. PRODUCT USE SELECTION GUIDE. <br /> COMPLETELY PROVIDED AS IF DRAWN IN FULL. CROSS REFERENCES SHOWN ON REFER TO SIMPSONS WEBSITE FOR REQUIREMENTS FOR NAILS, BOLTS, AND HANGERS USED <br /> DRAWINGS DO NOT NECESSARILY INDICATE ALL LIKE CONDITIONS AND DO NOT LIMIT HAZARDS (GUARDRAILS & SAFETY GLAZING) WITH PRESSURE TREATED WOOD. STANDARD HOT DIPPED GALVANIZED FASTERNERS, BOLTS, <br /> APPLICATION OF ANY DRAWING OR DETAIL. THEY MAY APPLY TO OTHER SAME OR AND NAILS MAY NOT ACCEPTABLE WITH THE NEW TYPES OF PRESSURE TREATED WOODS <br /> SIMILAR CONDITIONS NOT REFERENCED. 1. GUARDRAILS SHALL BE NO LESS THAN 36 INCHES IN HEIGHT. INTERMEDIATE RAILINGS (ACCORDING TO SIMPSON'S WEBSITE TECHNICAL PUBLICATIONS.). <br /> 10. KITCHEN LAYOUT IS SCHEMATIC ONLY. COORDINATE KITCHEN LAYOUT WITH ARE REQUIRED AND ARE TO BE ARRANGED SO THAT A 4-INCH SPHERE CANNOT PASS BUILDER / DEVELOPER SHALL BE RESPONSIBLE FOR VERIFYING WHICH FASTENERS ARE DR�-�WING USE NOTIFICI-�TION <br /> OWNER. CABINET STYLES AND MATERIALS SHALL BE SELECTED BY OWNER / THROUGH. ACCEPTABLE FOR USE AND SHALL TAKE LIABILITY FOR PERFORMANCE OF FASTENERS OR <br /> CONTRACTOR. 2. SAFETY GLAZING IS REQUIRED IN ALL DOORS, RAILINGS, AND TUB OR SHOWER CONNECTORS SELECTED AND USED ON THIS PROJECT. Thisseto£drawingsisbeingissuedasaProgressorPermitSetof <br /> 11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WALL BLOCKING ENCLOSURES. ANY GLAZING WITHIN A DOOR OPENING AND WITHIN 60 INCHES OF THE ANY REFERENCES ON STRUCTURAL DRAWINGS FOR THIS PROJECT TO PRESSURE TREATED Drawingsandissubjecttochangeandaddingofadditionalinformation <br /> and dra�vings as required by review of the Building Department in the <br /> AND BRACING REQUIRED FOR WALL AND CEILING MOUNTED ITEMS. FLOOR SHALL BE SAFETY GLAZING. FIXED GLAZING GREATER THAN 9 SQUARE FEET IN WOOD SHALL DEFER TO THE REQUIREMENTS LISTED ABOVE. jurisdiction�Uhere this project is lo�aced. <br /> 12. ALL NEW CONSTRUCTION SHALL BE STABILIZED AGAINST LATERAL MOVEMENT IN AREA AND W ITHIN 18 INCHES OF THE FLOOR IS TO BE SAFETY GLAZING. REFER TO 2009 Do NOT usE Txls D���NG Fox coNSTxucTioN uNLEss <br /> ACCORDANCE WITH THE REQUIREMENTS OF THE 2015 INTERNATIONAL RESIDENTIAL INTERNATIONAL RESIDENTIAL BUILDING CODE FOR ADDITIONAL AREAS OF SAFETY MOLD CONTROL Txls Dx�wING x��s��Bu1LDING DEP�xTntENT���PPxo��ED�� <br /> BUILDING CODE AND STATE OF WASHINGTON BUILDING CODE AND ALL APPLICABLE GLAZING. PROPER STORAGE AND HANDLING OF BUILDING PRODUCTS HELPS PREVENT MOLD sT��iP�PPLIEDBYTxEBu1LDi�GDF.P�xTniE�r uPON <br /> KEEP STOCKS OF LUMBER, PLYWOOD, ORIENTED-STRAND BOARD OSB , DRYWALL, AND OTHER co�tPLEr1oN oF 7�xE PEx�tir��TiEwPxocEss. <br /> SEISMIC REQUIREMENTS. � � Do not use this drawing for Bidding or Estimating Purposes unless <br /> INDOOR AIR QUALITY NOTES POROUS MATERIALS IN A DRY, COVERED STORAGE AREA. IF THE STOCKPILES ARE OUT IN THE auchorized bv Client.During ConscYu�rion Phase,the Clients General � <br /> ARCHITECTURAL SITE NOTES OPEN, AND IT LOOKS LIKE IT MIGHT RAIN, COVER THE MATERIALS WITH A GOOD TARP, ANCHORED Contractor(Builder) or Developer shall be responsible for ensuring that all <br /> 1. SOURCE SPECIFIC VENTILATION: SOURCE SPECIFIC EXHAUST VENTILATION SHALL BE DOWN SO THAT THE WIND DDES NOT BLOW IT OFF. WHEN THE MATERIALS ARE NEEDED, ConScru�rionPefsonnelo£cheGeneralContraccofandallSub�oncfa�cofs <br /> 1. REFER TO SURVEY (IF SURVEY WAS COMPLETED FOR THIS PROJECT) AND/OR CIVIL REQUIRED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, AND OTHER REMOVE THEM FROM BENEATH THE COVER WITHOUT ALLOWING THE REMAINDER TO GET WET aresupplied�vithallA ror�er/andmostcurrentdocuments. <br /> ENGINEERING DRAWINGS FOR ADDITIONAL NOTES AND INFORMATION FOR EXISTING ROOMS WHERE EXCESS WATER VAPOR OR COOKING ODOR IS PRODUCED. BATHROOM OR DAMP.BEFORE INSTALLING THE MATERIALS, INSPECT CAREFULLY FOR WATER DAMAGE, ARCHITECTURAL COPYRIGHT <br /> CONDITIONS. EXHAUST FANS AT 75 CFM, KITCHEN EXHAUST FANS AT 100 CFM. LAUNDRY EXHAUST STAINING, WARPING, OR INITIAL SIGNS OF MOLD GROWTH. SUCH SIGNS MIGHT BE VISIBLE <br /> 2. VERIFY ALL UNDERGROUND UTILITIES AND SITE GRADES PRIOR TO FANS AT 100 CFM. PATCHES OF MOLD, OF� MUSTY ODORS ASSOCIATED WITH MOLD OR MILDEW. DISCARD ANY This sheet of di���ings ma5�not be reprodu�ed in 1t�y Eorm Wichout <br /> CONSTRUCTION. 2. A WHOLE HOUSE FAN W/TIMER 100 CFM MIN., 1.5 SOMES WILL BE LOCATED IN THE SUCH MATERIALS IMMEDIATELY.INSTALL A ROOF OR COVER THE NEW CONSTRUCTION AS SOON priorappro�alofCarlJ.Colson-Ar�hite�tPllC. <br /> � � These document,the ideas,and designs incorporated herein as an <br /> 3. COORDINATE PROPERTY CORNERS W ITH SURVEYOR. LAUNDRY ROOM AT THE SECOND FLOOR. AS PRACTICAL. instniment of ser�ice shall rernain the properry of Carl J.Co15on- <br /> 4. CONTRACTOR SHALL VISIT THE SITE AND APPRAISE HIMSELF/ HERSELF OF THE 3. VENTILATION DUCTS: ALL DUCTS SHALL TERMINATE OUTSIDE THE BUILDING. .�r�hite�t PLLC and are soiel5�for the use on this project only.These <br /> EXISTING CONDITIONS AND SEQUENCE PRIOR TO ANY CLEARING OR DEMOLITION DRYING WOOD CONSTRUCTION PRIOR TO INSULATION OR DRYWALL INSTALLATION E"�les,drawings,ideas,or designs may not be tramsmitted electronicall}� <br /> WORK. WHEN THE BUILDING FRAME IS COMPLET AND EXTERIOR SIDING IS INSTALLED, CONTRACTOR �vithout express permission of:�rchitect.Theyare not be used b}�the <br /> 5. VERIFY ALL TOP OF SLAB ELEVATIONS AT ALL BUILDING AND PROPERTY LINES. SHALL USE A PIN-TYPE MOISTURE METER TO VERIFY MOISTURE CONTENT IN WOOD FRAMING �lientoran��otherparn�orentin�onotherprojects,inwholeorpart,or <br /> � as an extension to this project except b�r agreement in writing�uith <br /> 6. CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL MECHANICAL AND FLOOR SHEATHING, WALL SHEATHING, AND ROOF SHEATHING. appropriace6nan�ial�ompensarioncoCarlJ.Colson-�r�hice�cPLLC. <br /> ELECTRICAL PADS AND BASE, ALONG WITH POWER, WATER AND / OR DRAINAGE MOISTURE CONTENT OF ALL WOOD MEMBERS AND SHEATHING SHALL BE 15% OR LESS. IF THE Cop�-rightCarlJ.Colson-PLLC,2o17.��llright5reser�ed.O <br /> INSTALLATIONS BEFORE PROCEEDING WITH THE WORK. MOISTURE CONTENT IS HIGHER, CONTRACTOR SHALL USE A COMBINATION OF HIGH VOLUME <br /> FANS AND DEHUMIDIFIERS TO THOROUGHLY DRY THE WOOD FRAMING AND SHEATHING PRIOR TO ProjectNumber <br /> ANY INSTALLATION OF INSULATION OR DRYWALL. THIS SHOULD BE DONE TO HELP MINIMIZE ANY 2016-04 <br /> MOISTURE DAMAGE TO INTERIOR OF WOOD FRAMING SURFACES OR SHEATHING. sneet�ssUeoate - <br /> 03/27/15 � <br /> Drawn By <br /> Author General Notes ' <br /> Scale , <br /> 12" = 1'-0" Sheet Plot Date2/6/2017 9:56:51 AM ' <br /> www.CarlColsonArchitect.com <br />