Laserfiche WebLink
H V A C (MOTOR, COMPRESSOR, HEATER SIZES) <br /> OPERATION VOLTAGE 197 MIN. 253 MAX. <br /> COMPRESSOR 14.7 RLA 112 LRA <br /> INDOOR BLOWER FAN 2.2 FLA 1�3 HP <br /> � � OUTDOOR BLOWER FAN 1.5 FLA 1�5 HP <br /> HEAT STRIP 10 KVA 240 VOLT <br /> MINIMUM CIRCUIT AMPS 8') AMPS <br /> � <br /> N MAXIMUM OVERCURRENT PROTECTION 9O AMPS " <br /> (2) 8' x 4' WHITE BOARDS w/ ,.� <br /> MARKER TRAY (SHIP LOOSE� ELECTRIC OVERCURRENT PROTECTION SHALL BE DUAL ELEMENT <br /> INSTALLED ON SITE BY OTHERS PANEL TIME DELAY FUSE OR HACR CIRCUIT BREAKER <br /> e B a PANEL SCHEDULE <br /> #� <br /> � NOTE:ALL CONDUCTORS COPPER. 200 AMP 1� 22,000 AIC <br /> GFCI CKT TRIP WIRE VOLT 200 VOLT WIRE TRIP CKT <br /> DESCRIPTION DESCRIPTION <br /> NO. AMPS SIZE AMPS A B AMPS SIZE AMPS NO. <br /> 1 LIGHTS 20 12 792 �� �� 7208 4 90 HVAC 2 , <br /> � g 3 RECEPTACLES 20 12 1260 �� �� 7208 / / / 4 <br /> z � 5 RECEPTACLES 20 12 1080 �� �� 20 SPARE 6 <br /> Z <br /> �� �2 4 7 RECEPTACLES 20 12 972 � � -- -- 20 SPARE 8 • <br /> � <br /> � 9 Sr;cr _ � - - 2o SPARE 10 <br /> C �� 11 S=�;CE - �� �� - -- 20 SPARE 12 <br /> I � <br /> � U Q 13 SP%�CF.. - -- -- �� �� -- -- 20 SPARE 14 <br /> z � <br /> g g B 15 SFACF -- - -- �� �� - --• 20 SPARE 16 <br /> - - - �-- - - =� —c - ---r - - <br /> 17 ::�?:;cr _. _ �� �� _ 20 SPARE 18 <br /> - - - - - � �_- <br /> 19 SrAI:E _.. .._ �� �� _... 20 SPARE 20 <br /> � <br /> � <br /> ,� ;� � � � ELECTRICAL PLAN REVIEW <br /> �� � �' � LOAD CALCULATIONS � <br /> DAYLIGHTING � VOLTAGE: 120/240 PHASE: 1� ' <br /> � <br /> � �� A P A P[y ,pD �� CONNECTED LOAD CALC. LOAD <br /> I � LIGHTING <br /> I � EXTERIOR 72 VA x 125 % = 90 VA <br /> .\ / <br /> � INTERIOR 792 VA x 125 % = 990 VA <br /> SECONDARY — � <br /> —--- - - — —- (� - <br /> BIA REC�PTACLES <br /> i <br /> / � THRU 10,000 3240 VA x 100 % = 3240 VA <br /> --�-�J--�-�W OVER 10,000 0 VA x 50 % = 0 VA ' <br /> MOTORS, COMPR. � <br /> PRIMARY <br /> TOTAL 4416 VA x 100 % = 4416 VA <br /> LARGEST (3528) VA x 25 % = 882 VA <br /> NOTES: HEATING 10000 vA x 100 / = 1000o vA <br /> ELECTRICAL PLAN <br /> l. WHEN STRANDED WIRE IS USED, ALL TERMINATIONS ARE MADE TOTAL KVA 18.52 TOTAL KVA 19.62 <br /> BY A PRESSURE TERMINAL, BY TAILING OFF WITH SOLID 1�4" = 1'-0" ARS 2/1�16 CONNECTED CALCULATED <br /> CONDUCTORS OR OTHER APPROVED MEANS OF TERMINATION. LOAD AMPS 77,�7 LOAD AMPS 81 .74 <br /> 2. ALL CONDUCTORS ARE COPPER;TYPE THHN. <br /> 3. RATING OF STANDARD PANEL IS 22,000 A.I.C. <br /> E L E C T R I C A L S Y M B 0 L S � <br /> HEIGHT <br /> 4. WIRING METHOD IN METALLIC CONDUIT OR M.C. CABLE. SYMBOL DESCRIPTION TO TOP REMARKS <br /> �64 SINGLE POLE MOMENTARY SWITCH 48" LOW VOLT OCC SENSOR CONTROL <br /> 5. LIGHTING CONFORMS TO WASHINGTON STATE ENERGY CODE � DUPLEX RECEPT. 20" 180 VA EACH <br /> 51-11C, CHAPTER 4 SECTION C405. <br /> �WP� WEATHER PROOF/GRD. FAULT 16" 180 VA EACH <br /> b. THIS PLAN IS NOT AN"AS-BUILT'DRAWING <br /> � QUAD PIEX RECEPT. 20" 360 VA EACH <br /> OS OCCUPANCY SENSOR CEILING LOW VOLT w/ POWER PACK , <br /> QTY. SIZE DESCRIPTION O LIGHT SENSOR CEILING 0-10V DIMMING CONTROL <br /> ELECTRICAL PANEL 1 200 AMP 120 240V - SINGLE PHASE - STUB THRU - METALLIC RACEWAY SYSTEM ONE-LINE-DIAGRAM � PHONE/DATA BOX 20" STUB UP & DOWN w/ 3/4" ' <br /> � 200 AMP FEEDER PANEL FLEX CONDUIT . <br /> MAIN BREAKER � PULL STATION 48" ' <br /> LIGHTING 3 2 x 4 TROFFER (3) T-8 32 WATT TUBES - 0-10V PROG DIMMING BALLAST 120/240 1� � FIRE ALARM HORN/STROBE (INT) 84" 1/2" RACEWAY ONLY <br /> PAINT SUBSTANTIALLY RED <br /> 200 AMP � FIRE ALARM HORN/STROBE (EXT) 84" <br /> 6 2 x 4 TROFFER (3) T-8 32 WATT TUBES - ELECTRONIC BALLAST <br /> 1 72W LED FIXTURE w� PHOTO CELL O THERMOSTAT 48" TO TOP OF J-BOX <br /> 1/2" PVC 2" PVC STUB � PORCH LIGHT 84" 72 VA EACH <br /> STUB FOR BY BLAZER <br /> • H.V.A.C. 1 3 TON 10 kW BARD WALL HUNG HEAT PUMP w/ ECONOMIZER FUTURE (2) 3/0 Cu THHN PD 24" x 48" TROFFER w/ 0-10V 3 T-8 TUBE ELECT. BALLAST ` <br /> GROUNDING (1) 1/0 Cu THHN � PROGRESSIVE DIMMING BALLAS CEILWG gg VA EACH FIXTURE : <br /> THERMOSTAT � HONEYWELL w/ MICROPROCESSOR- 7 DAY PROGRAMMABLE AND _ (1� #4 Cu 4 , <br /> VISIONPRO_ TH8320U AUTOMATIC SETBACK- DEADBAND CONTROL BONDING (WIRE ON SITE BY OTHERS) � 24" x 48" TROFFER CEILING 3 T-8 TUBE ELECT. BALLAST <br /> 88 VA EACH FIXTURE <br /> g POWER PANEL 72" . <br /> 2-1-16 ELECTRICAL ENGINEERING REVIEW ARS COPYRIGHT 2016, BLAZER INDUSTRIES, INC. � MODULAR Classroom for.� Approved for Const: Job No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ File Copy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� 28 X 32 KC DA - Eve rett S�D■ <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE INDUSTRIES,�Nc. Drawn By: JwR � <br /> DATE REVISION BY WRITfEN PERMISSION OF BLAZER INDUSTRIES. �w•b�azerind.com WA. GOLD Pacific Mobile 14 BLMP-11 A3 Everett WA <br /> ■■ P.o.eox ass ■ Aumsville,OR 97325-0489 � Issue Date: 02/01/16 <br /> <• <br /> `� <br />