, I, 11 ' . . . .
<br /> .�_,'��„1,.�._ c _ _ _-_— - .
<br /> -. _ . _ _ _._..--_ - . �.
<br /> .•t
<br /> <'
<br /> ,:4 .
<br /> Et'
<br /> ,�&
<br /> FASTENING SCHEDULE MATERIAL LIST
<br /> ��
<br /> WALLS: FLOOR: ROOF: ,
<br /> PLATE—TO—STUD MIN. OF 3 — 0.121"x3" NAILS 2 x 8 FLOOR JOIST—TO—RIM MIN. OF 4— 0.131" x 3" NAILS ARCH. SHINGLES OVER SELF—ADHERED
<br /> ROOFING. . . . . . . . . . . . .
<br /> VW TACKBOARD—TO—STUD � INTERIOR SENCO P15 STAPLES & GLUE CLASS "A" BOTTOM BOARD—TO—JOIST 16 ga. x 3/8" WIDE CROWN Cs� 12" MAX. EDGES ONLY UNDERLAYMENT APPLIED SHINGLE FASHION ,
<br /> SHEETROCK—TO—STUD � INTERIOR 13ga.x1 5/8" SHEETROCK SCREWS AT 16" oc EDGE FLOOR DECKING—TO-2x JOIST 0.113" x 2 3/8" RING SHANK � 6" EDGE, 12" IN FIELD. USE —HIGH WIND APPLICATION— ,
<br /> • AND CONSTRUCTION ADHESIVE IN FIELD. CONSTRUCTION ADHESIVE ON JOISTS
<br /> SHEATHING. . . . . . . .. . .7/16" APA RATED (24/16) MINIMUM
<br /> BOTTOM PLATE—TO—FLOOR 0.131"x3" NAILS � 8" oc.
<br /> FRAMING . . . . . .. .. . . . .2 x 10 HF #2 RAFTERS � 24"oc
<br /> SHEATHING—TO—STUD AT SIDEWALL 16 GA. x I3�4" STAPLES O 6"oc EDGE, 12"oc FIELD ROOF:
<br /> w/ 2" FURRING ON BOTTOM
<br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING FURRING—TO—RAFTERS MIN. 4— M20 2 x 3 (MIN.) PLATES EACH SIDE
<br /> RIDGEBEAM . . . . . . .. . .DOUBLE 1 1/2" x 24" CONTINUOUS LVL 2.OE
<br /> SHEATHING—TO—STUD AT ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS ROOF RIM—TO—TOP PLATE 0.131" x 3" NAILS � 8" oc.
<br /> LEDGERS. .. . . .. . . . . . .2 x 4 D.F. TAPER CUT �:•
<br /> LAP SIDING FASTENED PER MANUFACTURER SPEC. LEDGER—TO—RIDGEBEAM 0.131" x 3" NAILS � 3" oc & 3 � BUTT JOINTS
<br /> RIMS. . . . . . . . . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE 5 '
<br /> THREE STUD CORNER CONNECTION 0.131"x3" NAILS � 12"oc. RAFTER—TO—RIDGEBEAM 4— 0.131" x 3" NAILS WITH 2 x 10 DF VENT BLOCKS • .
<br /> RIDGEBEAM—TO—RIDGEBEAM 4 ROWS � 0.131" x 3" NAILS � 12"oc INSULATION. . . . . . .. . .R38 CELLULOSE BLOW—IN OVER CLASS "A"
<br /> MATERIAL (AIR BARRIER COMPONENT)
<br /> SHEATHING—TO—ROOF MEMBERS 16ga x 13/4" STAPLES � 6" EDGE, 12" IN FIELD '
<br /> AIR BARRIER NOTES: CEILING. . .. . . .. . . . . . .SUSPENDED T—BAR (PER IBC 808) -
<br /> NOTE: SHEATHING TO BE INSTALLED PERPENDICULAR TO THE RAFTERS. OFFSET "ARMSTRONG SEISMIC RX CEILING"
<br /> THESE KEY AREAS SHALL BE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER—STRIPPING: SHEATHING 4 ft. BLOCK EDGES OF ANY PIECES LESS THAN 24"
<br /> —JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATELY SIZED BACKER ROD WITH MINIMUM ARCHITECTURAL . .. . .12" OVERHANG
<br /> 2" LAP AT ENDS. SOFFIT. . . . .. . . .. .. . . . .y4" FIBER CEMENT PANEL, PERFORATED FOR '
<br /> —JUNCTIONS BETWEEN WALLS AT:
<br /> —BUILDING CORNERS: USE CAU�KWG MODLINE CONNECTION: NOTE: A�� MOD�INES (DEFWED AS THE SPACE BETWEEN ADJOINING MODULES) VENTING AS REQUIRED
<br /> —STRUCTURAL FLOORS: USE SILL SEAL OR CAULKING MUST BE INSULATED AT THE ROOF, FLOOR AND WALLS ON SITE.
<br /> VENTING. . . .. . . . . . . . .SOFFIT AND RIDGE
<br /> —ROOFS (AT RIM): USE SILL SEAL OR CAULKING 1/2" BOLTS w 1 1 2 DIA. WASHERS � 6'-0" oc AND 8" FROM EACH
<br /> —PENETRATIONS OF UTILITY SERVICES THRU THE AIR BARRIER � ROOFS, WALLS, AND FLOORS: USE CAULKING, SPRAY RIDGEBEAMS � �
<br /> FOAM, OR AIR BARRIER TAPE. END (MINIMUM 2" EDGE DISTANCE) `
<br /> —BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AIR BARRIER TAPE. RIM JOISTS 1/2" BOLTS w/ 1 1/2" DIA. WASHERS � 4'-0" oc AND 8" FROM EACH WALLS' . ,
<br /> —JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. f
<br /> END (MINIMUM 2" EDGE DISTANCE) SIDING. . •. . . .. . . . . . . .FIBER CEMENT LAP SIDING WITH
<br /> —RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM ,
<br /> 8" EXPOSURE OVER BUILDING WRAP.
<br /> BUILDING WRAP TO EXTEND TO BOTTOM OF .
<br /> FLOOR RIM (MIN.) ,
<br /> SHEATHING. . . . . . . . . . .Yz" CDX PLYWOOD (MIN.15/32" RATED SHEATHING)
<br /> � g q FASCIA. . . . .. . . . . . . . .1 x 6
<br /> 4 6 TRIM . . . . . . . . . . . . . . . . .1 x 4 AT CORNERS,
<br /> ' A-4 A-4 WINDOWS, DOORS AND 1 x 6 � MODLINE
<br /> / �T � NOTE: 2"x 2" GALV. FLASHING UNDER CORNERS
<br /> I SHIP LOOSE TO BE INSTALLED ON SITE BY
<br /> I OTHERS �='
<br /> � �2 3 2 FRAMING. . . .. . . . . . . . .2 x 6 D.F. #3 or BETTER STUDS C� 16"oc ` �'
<br /> � �
<br /> LU26 HANGERS AT ALL RAFTERS i',+ I �2 A-4 A-4 ' "
<br /> '� OVER DOOR & WINDOW OPENINGS — I�/� �j {`�� -y- TOP PLATE. . . . . . . .. .2 x 6 CONTINUOUS LVL 2.OE
<br /> � WITH 6— 0.131" x 1,z" NAILS I � ' / �/� � 1 ' - -
<br /> , � � � . �\����\I
<br /> ^I� � I \���, I I �I�I/��II�I� �', � /� — ` BOTTOM PLATE. . . . . .2 x 6 D.F.
<br /> INTO LVL ROOF RIM � p ���,� � � �\ � �\ .I RIDGEBEAM BRACING �II���� � �� �/� k �
<br /> M .► � � `11�I\\I`�\\I SEE DETAIL /� �� 11/ !' `
<br /> _ ��� , i/►, =
<br /> *� . ::.: `��I\,\I I � � 5 I ' * . � INSULATION . . . . . . R-21 FIBERGLASS BATTS PLUS
<br /> - � i ,.
<br /> A-4 i��� - �
<br /> Y2" (R3 MIN.) CONTINUOUS FOAM BOARD AT
<br /> I _ �„ ' INTERIOR SIDE OF EXTERIOR WALLS
<br /> -- 12>» / .
<br /> SEAL - \ 4 INTERIOR FINISH. . .. . .MATERIAL INSTALLED FROM STUDS OUT
<br /> FLAME SPREAD EXT. WALLS:LAYER 1: FOAM INSULATION BOARD
<br /> AT ROOF 6 FT. WIDE WINDOWS � IS 25 OR LESS � � LAYER 2: 5/8" TYPE 'X' SHEETROCK (AIR BARRIER)
<br /> RIM/TOP k ` � —USE 2— 2x6 D.F. #2 w� MIN. R10 RIGID FILLER � LAYER 3: Y2" VINYLWRAP TACKBOARD (FINISH)
<br /> PLATE –USE (2) FULL HEIGHT STUDS AND a
<br /> (1) TRIM STUD AT EA. SIDE OF WINDOW m � eLL
<br /> w ABOVE WALL FINISH: LAYER 1: Yz" FOAM BOARD
<br /> � AT GABLE ENDS LAYER 2: 5/8" SHEETROCK -:
<br /> o �
<br /> �n�`D BACKER � —
<br /> � ROD �
<br /> � � � i SKIRTING . . . . . . . . . . . . .SHIP LOOSE
<br /> I AROUND �'
<br /> � INTERIOR � � ONE DRY CUP PERM VAPOR � FLOOR:
<br /> `— SIDE OF z � BARRIER ON THE WARM SIDE, �
<br /> _�
<br /> � WINDOWS � � i TYPICAL THRU—OUT BUILDING. � COVERING, .. . . . . .. . . .ON SITE BY OTHERS
<br /> � AND DOORS w o
<br /> � ' o _
<br /> '; � � 0 � DECKING. . . .. . . . . .. . .23/3z�� APA RATED T&G — GLUED AND NAILED
<br /> � o �-- i (AIR BARRIER COMPONENT)
<br /> CAULK WALL ` � �
<br /> . CORNERS FROM � � �
<br /> = - � FRAMWG. . . . . . . . . . . . .2 x 8 HF #2 JOISTS � 16"oc
<br /> TOP TO BOTTOM �
<br /> AT INTERIOR �_ �
<br /> I RIMS. . . . . . . . . . . . . . . . .2 x 8 CONTINUOUS L L . �.
<br /> �� 7 NOTE:12" HIGH MOISTURE BARRIER INSTALLED ON
<br /> � PERIMETER (OVER GYPSUM) AT RIMS AND END ,
<br /> SEAL � A-4 JOISTS
<br /> AT FLOOR � �i_ 3 4 JOIST HANGERS. .. . . .AT ALL RIMS '
<br /> RIM/BOTTOM �. i � A-4 A-4
<br /> PLATE / � —< � INSULATION . . . . . . . . . .R-30...USE TWO LAYERS OF R-15 �
<br /> " i � UNFACED FIBERGLASS BATT FIBERGLASS �
<br /> � i�� �iI , � � � ��� � � ,� � �� ��� I� i I �
<br /> I � . � ± r � � � BOTTOM COVER . . . . . .CLASS A
<br /> n � / � / .
<br /> � , � � �
<br /> 2„ 2-10-2016
<br /> SPACE
<br /> 13'-10" 13'-10" G� �SS�ET� . �
<br /> O vt ff�� tS'
<br /> �' ���' �l'��' :
<br /> F' . �:
<br /> � y r .
<br /> � � _
<br /> }r '
<br /> .O
<br /> ^�
<br /> _ �o��s f,G i s�o;l�`G����, •
<br /> S E C T I O N A A S-���E�L 4sr
<br /> 1/2" = 1'-0"
<br /> COPYRIGHT2016, BLAZER INDUSTRIES, INC. � MODULAR Classroom for. ApprovedforConst: Job No. 18567
<br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY
<br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ 28 x 32 KC DA - Eve rett S�D■ File Capy:
<br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� INDUSTRIES,�Nc. �.
<br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: JWR �
<br /> �� www.blazerind.com Wq. GOLD Pacific Mobile 14 BLMP-11 A3 Everett WA
<br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. ■■ p.o.soX 4ss ■ Aumsvi��e,OR 97325-0489 � Issue Date: OZ/01/16 ,