Laserfiche WebLink
, I, 11 ' . . . . <br /> .�_,'��„1,.�._ c _ _ _-_— - . <br /> -. _ . _ _ _._..--_ - . �. <br /> .•t <br /> <' <br /> ,:4 . <br /> Et' <br /> ,�& <br /> FASTENING SCHEDULE MATERIAL LIST <br /> �� <br /> WALLS: FLOOR: ROOF: , <br /> PLATE—TO—STUD MIN. OF 3 — 0.121"x3" NAILS 2 x 8 FLOOR JOIST—TO—RIM MIN. OF 4— 0.131" x 3" NAILS ARCH. SHINGLES OVER SELF—ADHERED <br /> ROOFING. . . . . . . . . . . . . <br /> VW TACKBOARD—TO—STUD � INTERIOR SENCO P15 STAPLES & GLUE CLASS "A" BOTTOM BOARD—TO—JOIST 16 ga. x 3/8" WIDE CROWN Cs� 12" MAX. EDGES ONLY UNDERLAYMENT APPLIED SHINGLE FASHION , <br /> SHEETROCK—TO—STUD � INTERIOR 13ga.x1 5/8" SHEETROCK SCREWS AT 16" oc EDGE FLOOR DECKING—TO-2x JOIST 0.113" x 2 3/8" RING SHANK � 6" EDGE, 12" IN FIELD. USE —HIGH WIND APPLICATION— , <br /> • AND CONSTRUCTION ADHESIVE IN FIELD. CONSTRUCTION ADHESIVE ON JOISTS <br /> SHEATHING. . . . . . . .. . .7/16" APA RATED (24/16) MINIMUM <br /> BOTTOM PLATE—TO—FLOOR 0.131"x3" NAILS � 8" oc. <br /> FRAMING . . . . . .. .. . . . .2 x 10 HF #2 RAFTERS � 24"oc <br /> SHEATHING—TO—STUD AT SIDEWALL 16 GA. x I3�4" STAPLES O 6"oc EDGE, 12"oc FIELD ROOF: <br /> w/ 2" FURRING ON BOTTOM <br /> ALL EDGES SUPPORTED BY FRAMING OR BLOCKING FURRING—TO—RAFTERS MIN. 4— M20 2 x 3 (MIN.) PLATES EACH SIDE <br /> RIDGEBEAM . . . . . . .. . .DOUBLE 1 1/2" x 24" CONTINUOUS LVL 2.OE <br /> SHEATHING—TO—STUD AT ENDWALL SEE ENDWALL FASTENING NOTES ON ELEVATIONS ROOF RIM—TO—TOP PLATE 0.131" x 3" NAILS � 8" oc. <br /> LEDGERS. .. . . .. . . . . . .2 x 4 D.F. TAPER CUT �:• <br /> LAP SIDING FASTENED PER MANUFACTURER SPEC. LEDGER—TO—RIDGEBEAM 0.131" x 3" NAILS � 3" oc & 3 � BUTT JOINTS <br /> RIMS. . . . . . . . . . . . . . . . .2 x 6 CONTINUOUS LVL 2.OE 5 ' <br /> THREE STUD CORNER CONNECTION 0.131"x3" NAILS � 12"oc. RAFTER—TO—RIDGEBEAM 4— 0.131" x 3" NAILS WITH 2 x 10 DF VENT BLOCKS • . <br /> RIDGEBEAM—TO—RIDGEBEAM 4 ROWS � 0.131" x 3" NAILS � 12"oc INSULATION. . . . . . .. . .R38 CELLULOSE BLOW—IN OVER CLASS "A" <br /> MATERIAL (AIR BARRIER COMPONENT) <br /> SHEATHING—TO—ROOF MEMBERS 16ga x 13/4" STAPLES � 6" EDGE, 12" IN FIELD ' <br /> AIR BARRIER NOTES: CEILING. . .. . . .. . . . . . .SUSPENDED T—BAR (PER IBC 808) - <br /> NOTE: SHEATHING TO BE INSTALLED PERPENDICULAR TO THE RAFTERS. OFFSET "ARMSTRONG SEISMIC RX CEILING" <br /> THESE KEY AREAS SHALL BE SEALED BY CAULKING, GASKETS, TAPE OR WEATHER—STRIPPING: SHEATHING 4 ft. BLOCK EDGES OF ANY PIECES LESS THAN 24" <br /> —JOINTS AROUND FENESTRATION (WINDOWS AND DOOR FRAMES): USE APPROPRIATELY SIZED BACKER ROD WITH MINIMUM ARCHITECTURAL . .. . .12" OVERHANG <br /> 2" LAP AT ENDS. SOFFIT. . . . .. . . .. .. . . . .y4" FIBER CEMENT PANEL, PERFORATED FOR ' <br /> —JUNCTIONS BETWEEN WALLS AT: <br /> —BUILDING CORNERS: USE CAU�KWG MODLINE CONNECTION: NOTE: A�� MOD�INES (DEFWED AS THE SPACE BETWEEN ADJOINING MODULES) VENTING AS REQUIRED <br /> —STRUCTURAL FLOORS: USE SILL SEAL OR CAULKING MUST BE INSULATED AT THE ROOF, FLOOR AND WALLS ON SITE. <br /> VENTING. . . .. . . . . . . . .SOFFIT AND RIDGE <br /> —ROOFS (AT RIM): USE SILL SEAL OR CAULKING 1/2" BOLTS w 1 1 2 DIA. WASHERS � 6'-0" oc AND 8" FROM EACH <br /> —PENETRATIONS OF UTILITY SERVICES THRU THE AIR BARRIER � ROOFS, WALLS, AND FLOORS: USE CAULKING, SPRAY RIDGEBEAMS � � <br /> FOAM, OR AIR BARRIER TAPE. END (MINIMUM 2" EDGE DISTANCE) ` <br /> —BUILDING ASSEMBLIES USED AS DUCTS OR PLENUMS: USE BACKER ROD, CAULK, SPRAY FOAM OR AIR BARRIER TAPE. RIM JOISTS 1/2" BOLTS w/ 1 1/2" DIA. WASHERS � 4'-0" oc AND 8" FROM EACH WALLS' . , <br /> —JOINTS, SEAMS, AND PENETRATIONS OF VAPOR RETARDANTS: USE CAULK OR APPROVED TAPE. f <br /> END (MINIMUM 2" EDGE DISTANCE) SIDING. . •. . . .. . . . . . . .FIBER CEMENT LAP SIDING WITH <br /> —RECESSED LIGHTING FIXTURES: USE CAULK OR SPRAY FOAM , <br /> 8" EXPOSURE OVER BUILDING WRAP. <br /> BUILDING WRAP TO EXTEND TO BOTTOM OF . <br /> FLOOR RIM (MIN.) , <br /> SHEATHING. . . . . . . . . . .Yz" CDX PLYWOOD (MIN.15/32" RATED SHEATHING) <br /> � g q FASCIA. . . . .. . . . . . . . .1 x 6 <br /> 4 6 TRIM . . . . . . . . . . . . . . . . .1 x 4 AT CORNERS, <br /> ' A-4 A-4 WINDOWS, DOORS AND 1 x 6 � MODLINE <br /> / �T � NOTE: 2"x 2" GALV. FLASHING UNDER CORNERS <br /> I SHIP LOOSE TO BE INSTALLED ON SITE BY <br /> I OTHERS �=' <br /> � �2 3 2 FRAMING. . . .. . . . . . . . .2 x 6 D.F. #3 or BETTER STUDS C� 16"oc ` �' <br /> � � <br /> LU26 HANGERS AT ALL RAFTERS i',+ I �2 A-4 A-4 ' " <br /> '� OVER DOOR & WINDOW OPENINGS — I�/� �j {`�� -y- TOP PLATE. . . . . . . .. .2 x 6 CONTINUOUS LVL 2.OE <br /> � WITH 6— 0.131" x 1,z" NAILS I � ' / �/� � 1 ' - - <br /> , � � � . �\����\I <br /> ^I� � I \���, I I �I�I/��II�I� �', � /� — ` BOTTOM PLATE. . . . . .2 x 6 D.F. <br /> INTO LVL ROOF RIM � p ���,� � � �\ � �\ .I RIDGEBEAM BRACING �II���� � �� �/� k � <br /> M .► � � `11�I\\I`�\\I SEE DETAIL /� �� 11/ !' ` <br /> _ ��� , i/►, = <br /> *� . ::.: `��I\,\I I � � 5 I ' * . � INSULATION . . . . . . R-21 FIBERGLASS BATTS PLUS <br /> - � i ,. <br /> A-4 i��� - � <br /> Y2" (R3 MIN.) CONTINUOUS FOAM BOARD AT <br /> I _ �„ ' INTERIOR SIDE OF EXTERIOR WALLS <br /> -- 12>» / . <br /> SEAL - \ 4 INTERIOR FINISH. . .. . .MATERIAL INSTALLED FROM STUDS OUT <br /> FLAME SPREAD EXT. WALLS:LAYER 1: FOAM INSULATION BOARD <br /> AT ROOF 6 FT. WIDE WINDOWS � IS 25 OR LESS � � LAYER 2: 5/8" TYPE 'X' SHEETROCK (AIR BARRIER) <br /> RIM/TOP k ` � —USE 2— 2x6 D.F. #2 w� MIN. R10 RIGID FILLER � LAYER 3: Y2" VINYLWRAP TACKBOARD (FINISH) <br /> PLATE –USE (2) FULL HEIGHT STUDS AND a <br /> (1) TRIM STUD AT EA. SIDE OF WINDOW m � eLL <br /> w ABOVE WALL FINISH: LAYER 1: Yz" FOAM BOARD <br /> � AT GABLE ENDS LAYER 2: 5/8" SHEETROCK -: <br /> o � <br /> �n�`D BACKER � — <br /> � ROD � <br /> � � � i SKIRTING . . . . . . . . . . . . .SHIP LOOSE <br /> I AROUND �' <br /> � INTERIOR � � ONE DRY CUP PERM VAPOR � FLOOR: <br /> `— SIDE OF z � BARRIER ON THE WARM SIDE, � <br /> _� <br /> � WINDOWS � � i TYPICAL THRU—OUT BUILDING. � COVERING, .. . . . . .. . . .ON SITE BY OTHERS <br /> � AND DOORS w o <br /> � ' o _ <br /> '; � � 0 � DECKING. . . .. . . . . .. . .23/3z�� APA RATED T&G — GLUED AND NAILED <br /> � o �-- i (AIR BARRIER COMPONENT) <br /> CAULK WALL ` � � <br /> . CORNERS FROM � � � <br /> = - � FRAMWG. . . . . . . . . . . . .2 x 8 HF #2 JOISTS � 16"oc <br /> TOP TO BOTTOM � <br /> AT INTERIOR �_ � <br /> I RIMS. . . . . . . . . . . . . . . . .2 x 8 CONTINUOUS L L . �. <br /> �� 7 NOTE:12" HIGH MOISTURE BARRIER INSTALLED ON <br /> � PERIMETER (OVER GYPSUM) AT RIMS AND END , <br /> SEAL � A-4 JOISTS <br /> AT FLOOR � �i_ 3 4 JOIST HANGERS. .. . . .AT ALL RIMS ' <br /> RIM/BOTTOM �. i � A-4 A-4 <br /> PLATE / � —< � INSULATION . . . . . . . . . .R-30...USE TWO LAYERS OF R-15 � <br /> " i � UNFACED FIBERGLASS BATT FIBERGLASS � <br /> � i�� �iI , � � � ��� � � ,� � �� ��� I� i I � <br /> I � . � ± r � � � BOTTOM COVER . . . . . .CLASS A <br /> n � / � / . <br /> � , � � � <br /> 2„ 2-10-2016 <br /> SPACE <br /> 13'-10" 13'-10" G� �SS�ET� . � <br /> O vt ff�� tS' <br /> �' ���' �l'��' : <br /> F' . �: <br /> � y r . <br /> � � _ <br /> }r ' <br /> .O <br /> ^� <br /> _ �o��s f,G i s�o;l�`G����, • <br /> S E C T I O N A A S-���E�L 4sr <br /> 1/2" = 1'-0" <br /> COPYRIGHT2016, BLAZER INDUSTRIES, INC. � MODULAR Classroom for. ApprovedforConst: Job No. 18567 <br /> THIS MATERIAL IS THE EXCLUSIVE PROPERTY <br /> OF BLAZER INDUSTRIES, INC.AND SHALL ■■ 28 x 32 KC DA - Eve rett S�D■ File Capy: <br /> NOT BE REPRODUCED, USED, OR DISCLOSED �� INDUSTRIES,�Nc. �. <br /> TO OTHERS EXCEPT AS AUTHORIZED BY THE Drawn By: JWR � <br /> �� www.blazerind.com Wq. GOLD Pacific Mobile 14 BLMP-11 A3 Everett WA <br /> DATE REVISION BY WRITTEN PERMISSION OF BLAZER INDUSTRIES. ■■ p.o.soX 4ss ■ Aumsvi��e,OR 97325-0489 � Issue Date: OZ/01/16 , <br />