Laserfiche WebLink
o .-, a <br /> � o � <br /> r' 'oc <br /> v � <br /> Y rn �v <br /> . _ __.. . . _ ._.__.. . __.._... .__--� ---_. . . . '� C L <br /> GENERAL NOTES - MECHANICAL DRAWING INDEX � m 3 <br /> � _ � <br /> M1.0 MECHANICAL LEGEND AND GENERAL NOTES "> � � - <br /> 1. COORDINATE MECHANICAL WORK WiTH THAT OF OTHER � 3 � <br /> TRADES (ARCHITECTURAL AND STRUCTURAL). REFER TO M1.1 MECHANICAL EQUIPMENT SCHEDULES � v � <br /> ARCHITECTURAL AND STRUCTURAL DRAWINGS AND � v o - <br /> SPECIFICATIONS. COORDINATION SHALL OCCUR PRIOR TO `" " " <br /> EXISTING FABRICATION, PURCHASE,AND/OR INSTALLATION OF ALL <br /> ROOF DECKING WORK. GENERAL N �� ��� <br /> � � , v <br /> � m u m u c <br /> DRAIN EXTENSION �u � � <br /> TAPERED � °' � � <br /> INSULATION 2. COORDINATE PLUMBING SYSTEMS ROUTING PRIOR TO EXISTING MECHANICAL TO BE � � � <br /> OVERFLOW DRAIN / REMOVED E <br /> ROOFING INSTALLATION. ° <br /> �C v <br /> 2" HIGH WATER DAM MEMBRANE EXISTING MECHANICAL TO " <br /> ROOF DRAIN 3. UNLESS OTHERWISE SPECIFIED, THE GENERAL REMAIN � <br /> CONTRACTOR (GC)SHALL BE RESPONSIBLE FOR PAINTING, <br /> CUTTING, AND PATCHING OF EXISTING FLOORS, WALLS, NEW MECHANICAL WORK = <br /> AND PARTITIONS IN THE EXISTING BUILDING. <br /> — — — <br /> MATCHLINE OR PROPERTY <br /> 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFE LINE <br /> KEEPING OF HIS OWN PROPERTY ON THE JOB SITE. � B• C a <br /> ' OWNER ASSUMES NO RESPONSiBILITY FOR PROTECTION — ' ENLARGED PLAN BOUNDARY �� Q <br /> DRAIN SUMP RE EIVER OF PROPERTIES AGAINST FIRE, THEFT, AND � � vi <br /> ON ROOF DECK � DETAIL/PLAN IDENTIFIER � '� <br /> UNDERDECK CLAMP ENVIRONMENTAL CONDITIONS. Mi.o� � o <br /> RL ORL � <br /> ENERGY CODE NOTES REVISION DEFINITION AREA, 4�4764 � � <br /> AREA ENCIRCLED CONTAINS � �¢, � <br /> NOTE: CHANGES MADE SUBSEQUENT a <br /> SEE ARCHITECTURAL 1. PIPING AND DUCT INSULATION: COMPLY WITH TO PREVIOUS ISSUE (��i3�iot8 <br /> ROOFING DETAILS FOR THICKNESSES AND TYPES LISTED IN ENERGY CODE ' <br /> TYPE OF ROOFING & ENFORCED BY AHJ UNLESS MORE STRINGENT <br /> ROOF ELEVATIONS. REQUIREMENTS ARE SPECIFIED. Q REVISION CALLOUT <br /> ' 2. RECORD DRAWINGS: SUBMIT TO THE BUILDING OWNER � FLAG NOTE CALLOUT <br /> D ETAI L - ROO F D RAI N PER ENERGY CODE ENFORCED BY THE LOCAL AHJ. <br /> � 3. OPERATION AND MAINTENANCE MANUALS: SUBMIT TO THE O DEMOLITION NOTE TAG <br /> M�.o SCALE: NONE <br /> BUILDING OWNER PER ENERGY CODE ENFORCED BY THE <br /> LOCAL AHJ. aHu-o� MECHANICAL EQUIPMENT TAG . <br /> -------- ------ ----- --------- - -- ------- — ----------------- - -_ __------ —----— <br /> ' 4. THIS BUILDING AND ITS ENERGY SYSTEMS HAVE BEEN ' <br /> DESIGNED TO COMPLY WITH ENERGY CODE ENFORCED BY N NORTH ARROW <br /> THE LOCAL AHJ. CONTRACTOR IS RESPONSIBLE FOR <br /> ' CORRECT INSTALLATION OF ENERGY CONSERVATION <br /> ' MEASURES. <br /> ' � INVERT ELEVATION OR POC / n <br /> PIPE HANGER AS NOTED IN THREADED ROD; PIPING �"� 7 <br /> SPECIFICATIONS. ATTACH TO STRUCTURE. � ` <br /> PIPE ELBOW UP OR PIPE TEE � O <br /> UP AND DOWN Q � <br /> INSULATION AS SHOWN RIGID INSULATION AS PIPE ELBOW DOWN � <br /> ON PLANS &NOTED IN NOTED IN SPECS. � Q <br /> SPECIFICATIONS. O PIPE TEE UP � U <br /> � � <br /> ' PIPE TEE DOWN M � � <br /> W � �}� � <br /> PIPE RISE Q vJ <br /> PIPE CAP � O �1 ' ' <br /> � W <br /> WCO CLEANOUT- FREE STANDING � W <br /> PIPE AS SHOWN ON GALV. METAL SHIELD,AS WALL MOUNTED � <br /> PLANS & NOTED IN 6" MIN. NOTED IN SPECS., � z � Q <br /> SPECIFICATIONS. BETWEEN HANGER& --� �— PIPE BREAK � � <br /> 10" MIN. INSULATION, UP TO W � � � <br /> CENTERLINE OF PIPE. PIPE CONNECTION <br /> � � y � <br /> STORM DRAINAGE PIPING SYSTEM <br /> Z � � �- <br /> _ � � W <br /> • ROOF DRAIN V O N � <br /> 2 DETAIL - INSULATED PIPE HANGER z � W <br /> M�.o SCALE: NONE o OVERFLOW ROOF DRAIN O > <br /> W � 00 W <br /> R� RAIN LEADER <br /> _ _ _ _ __ oR� OVERFLOW RAIN LEADER <br /> ABBREVIATIONS <br /> QJ DIAMETER, PHASE HORIZ HORIZONTAL TEMP TEMPERATURE . <br /> TOD TOP OF DUCT <br /> ABV ABOVE IE INVERT ELEVATION TOP TOP OF PIPE REV. RELEASE DATE <br /> AFF ABOVE FINISHED FLOOR IN. INCH TOS TOP OF STEEL <br /> AG ABOVE GROUND IN.WG INCHES WATER COLUMN 1 OWNER REVIEW 12/19/17 <br /> AHJ AUTHORITY HAVING JURISDICTION SQ. FT. SQUARE FOOT 2 PERMIT SET 06/13/18 <br /> L LENGTH <br /> BF BELOWFLOOR LBS POUND UG UNDERGROUND <br /> BLW BELOW UNO UNLESS NOTED OTHERWISE <br /> BOP BOTTOM OF PIPE MC MECHANICAL CONTRACTOR <br /> BOT BOTTOM MECH MECHANICAL W WASTE,WATT,WIDE,WATER <br /> MIN M�NIMUM W/ WITH <br /> CLG CEILING,COOLING WC WATER CLOSET,WATER COLUMN <br /> CO CLEANOUT WCO WALL CLEANOUT <br /> COTG CLEANOUT TO GRADE NA NOT APPLICABLE WSEC WASHINGTON STATE ENERGY CODE <br /> NIC NOT IN CONTRACT WT WEIGHT <br /> D DRAIN NTS NOT TO SCALE <br /> DI DUCTILE IRON <br /> DIA DIAMETER ORD OVERFLOW ROOF DRAIN <br /> DIM DIMENSION ORL OVERFLOW RAIN LEADER <br /> (E) EXISTING POC POINT OF CONNECTION HARGIS PROJECT NO. 09194.35 <br /> EL ELEVATION DRAWN BY DO <br /> QTY QUANTITY CHECKED BY BC <br /> APPROVED BY BC <br /> RD ROOF DRAIN SHEET TITLE <br /> RL RAIN LEADER <br /> _ , . _ _ _._. ..,_ � <br /> LEVEL 1 - <br /> `�'-` MECHANICAL <br /> FCO FLOOR CLEANOUT �,_ <br /> FLR FLOOR � <br /> : ,�_ . . . � ; : <br /> FLOOR PLAN <br /> GALV GALVANIZED <br /> GPM GALLONS PER MINUTE SHEET NUMBER <br /> NOT ALL SYMBOLS MAY APPEAR ON THE DRAWINGS <br /> M1 . o <br />