Laserfiche WebLink
Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: COCOON HOUSE YOUTH CENTER Date 10/6/2017 <br /> The following information is necessary to check a permit application for compliance with the lighting,motor,and electrical requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicability Location in Building Department <br /> (yes,no,na) Code Section Component Compliance information required in permit documents Documents Notes <br /> C405.2.5- Hotel/motel guest Indicate method of automatic control-vacancy or captive key <br /> NA Item 3 rooms control of all installed luminaires and switched receptacles in NA NA <br /> guest room <br /> C405.2.5- Supplemental task Indicate method and location of automatic shut-off vacancy <br /> Yescontrol for supplemental task lighting,including under-shelf or A SERIES NA <br /> Item 4 lighting <br /> under-cabinet lighting <br /> Indicate on plans eligible non-visual lighting applications, NA NA <br /> include sq.ft.area of each lighting control zone; _ <br /> C405.2.5- Lighting for non- Indicate on plans that non-visual lighting are controlled <br /> NAindependently from both general area lighting and other lighting NA NA <br /> Item 5 visual applications <br /> applications within the same space; _ <br /> Indicate method of manual lighting control and applicable NA NA <br /> automatic lighting control _ <br /> Indicate on plans that lighting equipment for sale or <br /> demonstration are controlled independently from both general Lighting equipment NA NA <br /> C405.2.5- area lighting and other lighting applications within the same <br /> NA Item 6 for sale or space; <br /> demonstration <br /> Indicate method of manual lighting control and applicable NA NA <br /> automatic lighting control _ <br /> Identify on plans egress fixtures that function as both normal A SERIES NA <br /> and emergency means of egress illumination; _ <br /> Provide calculation of lighting power density of total egress A SERIES NA <br /> Yes C405.2.5- Means of egress lighting; <br /> Item 7 lighting If total egress lighting power density is greater than 0.02 W/sq. <br /> ft.,indicate on plans egress fixtures requiring automatic shut-off A SERIES NA <br /> during unoccupied periods; <br /> Indicate method of automatic shut-off control A SERIES NA <br /> Indicate on exterior lighting plans and fixture schedules the <br /> automatic lighting control method,control sequence,and NA NA <br /> locations served; <br /> For building facade and landscape lighting,indicate automatic <br /> controls shut off lighting as a function of dawn/dusk and fixed NA NA <br /> NA C405.2.7 Exterior lighting opening/closing time; <br /> controls <br /> For all other exierior lighting,indicate automatic controls shut <br /> off lighting as a function of available daylight;include control <br /> sequence that also reduces lighting power by at least 30% NA NA <br /> between 12am-6am,or from 1 hour after closing to 1 hour <br /> before opening,or based upon motion sensor <br /> Exterior building For building grounds fixtures greater than 100 watts,indicate <br /> NA C405.5.1 grounds lighting on plans whether fixtures have efficacy greater than 80 lumens NA NA <br /> controls or;are controlled by motion sensor,or are exempt lighting per <br /> C405.5.2 <br /> Indicate location(s)of master control switch(es)intended to <br /> Area controls- control multiple independent switches;circuit breaker may not A SERIES NA <br /> Yes C405.2.5 Master control be used as a master control switch; <br /> switches and circuit <br /> power limit Verify that no 20 amp circuit controlled by a single switch or A SERIES NA <br /> automatic control is loaded beyond 80% _ <br /> To comply with additional efficiency package option,indicate <br /> on plans all interior lighting fixtures that are individually A SERIES NA <br /> addressed and provided with continuous dimming,or exception <br /> Enhanced digital taken; <br /> Yes C406.4 - - <br /> lighting controls Include calculation of percent total installed interior lighting <br /> power that is configured with required enhanced lighting control A SERIES NA <br /> functions(min 90%to comply with additional efficiency <br /> package option) <br /> If claiming lighting system commissioning exemption provide A SERIES NA <br /> supporting calculation; <br /> Identify applicable commissioning documentation requirements <br /> Yes C405.13 Lighting system per Section C408 or eligibility for exception; A SERIES NA <br /> C408.3 functional testing <br /> Provide written procedures for functional testing of all <br /> A SERIES NA <br /> automatic controls and describe the expected system response <br /> (7(41/5) <br />