My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3530 COLBY AVE COCOON HOUSE 2020-01-13
>
Address Records
>
COLBY AVE
>
3530
>
COCOON HOUSE
>
3530 COLBY AVE COCOON HOUSE 2020-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 10:43:19 AM
Creation date
1/13/2020 10:37:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3530
Tenant Name
COCOON HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ENGINEERING <br /> PUBLIC SERVICES DEPARTMENT <br /> November 27, 2017 <br /> Scott Schreffler <br /> GGLO Design <br /> 1301 1st Ave, STE 301 <br /> Seattle, WA 98101 <br /> RE: Owner: Cocoon House <br /> Job Address: 3530 Colby Ave <br /> Plan Check Number: B1710-022 <br /> Dear Mr. Schreffler, <br /> In response to your application for a construction permit, your plans have been examined and you <br /> are advised that revisions may be necessary before a permit can be issued. Please review and <br /> respond to the comments below. These comments address building issues only. Additional <br /> revisions or additions may be required by other departments (such as Public Works, Planning, or <br /> Fire). All required submittals must be of sufficient detail and information to ensure that the <br /> proposed structure will be constructed in compliance with all adopted codes. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of construction documents <br /> reflecting the corrections requested. All revisions require the person delivering the <br /> drawings to replace the revisions into the two sets here at our offices. For significant <br /> revisions, or if the revisions are coming directly from a document printing facility, <br /> please make arrangements with them to print and deliver two replacement sets. <br /> Structural <br /> 1. On Sheet S-010, the Kzt factor of 1.24 is indicated on the Design Criteria, however a Kzt <br /> was determined on the permit calculations. Please clarify which condition is correct. <br /> 2. Please provide a diaphragm design for all floors. Please indicate and provide details and/or <br /> additional calculations indicating the locations and designs of drag struts and transfer <br /> conditions through diaphragms where required by computations. <br /> 3. Please provide drift calculations for the structure. <br /> 4. For the holddown permit calculations pages HD 1 to HD 4, it appears that these <br /> computations are covering a PT slab, but a PT slab does not occur on the drawings. It <br /> appears that these are"stock"calculations please clarify. Also, please indicate how the <br /> holddown forces are meeting the requirements of ACI 318-14 Section 17.3.2.1. <br /> a e1of2 <br /> CITY OF EVERE1T • 3200 Cedar Street • Everett, WA 98201 • (425) 257-8810 • Fax(425) 257-8857 <br />
The URL can be used to link to this page
Your browser does not support the video tag.