Laserfiche WebLink
Interior Lighting - Space-By-Space Method LTG-INT-SPACE <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2,R3,R4 over 3 stories and all R1 Revised August 2016 <br /> Project Title: COCOON HOUSE YOUTH CENTER Date 10/6/2017 <br /> Calculation C C Addition- C Addition For Building Department Use <br /> Area NOTE 9 stand alone +existing <br /> C Spaces where<50%of C Spaces where>_50%of `C <br /> luminaires are replaced luminaires are replaced <br /> LPA 0 Standard C Additional Efficiency Package Option C <br /> Calculation C406.3 Reduced Interior Lighting Power <br /> To comply with C406.3,the Proposed LPD shall be 25%lower than the Target LPA. <br /> Type Refer to C406.3 for additional requirements. <br /> Maximum Allowed Lighting Wattage NOTE 1 <br /> Location(plan#, Height'""" Gross Interior Allowed Watts Allowed <br /> room#) Space Type 2 Area in ft2 Watts per ft2 (watts/ftz x area) <br /> Level 1 Stairwell 468 0.550 257 <br /> Level I Electrical/mechanical 428 0.760 325 <br /> Level 1 Lobby:elevator 511 0.510 2 61 <br /> Level 1 Office:Open plan 10124 0.780 7897 <br /> Level 2-3 Stairwell 700 0.550 385 <br /> Level 2-3 Electrical/mechanical 66 0.760 50 <br /> Level 2-3 Storage room 268 0.500 134 <br /> Level 2-3 Corridor:all other 2366 0.530 1254 <br /> Level 2-3 Lounge/breakroom:all other 2988 0.580 1733 <br /> Level 2-3 Office:Enclosed 918 0.890 817 <br /> Level 2-3 Restroom:all other 214 0.780 167 <br /> Level 2-3 Laundry/washing area 368 0.480 177 <br /> Total Area 19419 <br /> Retail Display Allowance from LTG-INT-DISPLAY <br /> Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY"OTE 8 Allowed Watts 13457 <br /> Proposed Lighting Wattage NU I 3 <br /> Location(plan#, Number of Watts/ Watts <br /> room#) Fixture Description NOTE 4,s,6 Fixtures Fixture NOTE 7 Proposed <br /> Level 1 -Elevator L1 b-LED Cylinder Down Light 9 38 392 <br /> Lobby <br /> Level 1 -BOH, L4b-LED Strip Light 15 25 375 <br /> Stairs <br /> Level 1 -Shell& L17-LED Strip Light 65 25 1625 <br /> Core <br /> Level 2&3- POD <br /> Living Rooms, L1 -LED Recessed Down Light 110 15 1650 <br /> BOH,Restrooms <br /> Level 2&3-BOH, L4/L4a/L4b-LED Strip Light 26 25 650 <br /> Laundry,Stairs <br /> Level 2&3- POD L11 -LED Suspended Linear Down Light 2 4 8 <br /> Lighting Room <br /> Level 2&3 L14/L14a-LED Surface Mount Cylinder 16 40 640 <br /> Corridor <br /> Level 2&3- POD L15-LED Suspended Linear Down Light 4 25 100 <br /> Lighting Room <br /> Level 2&3 L16- LED Recessed Slot Light 14 3 42 <br /> Corridor <br /> Proposed Retail Display Lighting from LTG-INT-DISPLAY 3 9 <br /> Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 5432 / <br />