Laserfiche WebLink
SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2.R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Cocoon House Youth Center Date 10/06/2017 <br /> % 17.5 k Max.Target: 30% For Building Department Use <br /> Fenestration Area asgross above-grade wall area 9 <br /> Skylight Area as%gross roof area 0.9% Max.Target: 3% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating.or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included <br /> in this worksheet.Enter target SHGC values for this fenestration under proposed SHGC,so it <br /> is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x f SHGC x Area(A)= SHGC x A <br /> Skylights CPD#MIL-A-218-01143-00002 0.34 127 43 0.35 127 44.5 <br /> SHGC 0.35 <br /> Skylight Totals 127.0 43.2 127.0 44.5 <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> Fixed Vinyl CPD#.VPI-A-18-01115-00001 0.27 77 21 PF<0.2 0.40 3140 1256.0 <br /> Operable/A <br /> caning CPD#:VPI-A-20-01199-00001 0.22 376 83 0.25PF<0.5 0.48 <br /> Operable/c 0.22 1273 280 0.64 <br /> asement CPD#:VPI-A-29-02206-00001 PF>_0.5 <br /> Double <br /> Pane metal 2015 WSEC Table C303.1.3(3) 0.40 223 89 ++If projection factor(PF)credits are <br /> applied to the proposed design,Target <br /> Fixed SHGC will sum fenestration area by PF <br /> storefront NFRC CMA#P-KAW-14188 0.34 299 101 category. <br /> Fixed <br /> Aluminum 0.34 668 227 <br /> window CPD#:MIL-A-148-03435-00002 <br /> Oper <br /> aluminum/c 0.29 110 32 <br /> asement CPD#:MIL-A-187-03898-00001 <br /> Hollow <br /> metal door NFRC RPT#:A8255.01-116-45 0.38 114 43 <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 3140.0 875.9 3140.0 1256.0 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> [ North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID Category <br /> PF<0.2 0.53 <br /> 0.2<PF<0.5 0.58 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design,Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 3267.0 919.1 3267.0 1300.5 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br />