My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3530 COLBY AVE COCOON HOUSE 2020-01-13
>
Address Records
>
COLBY AVE
>
3530
>
COCOON HOUSE
>
3530 COLBY AVE COCOON HOUSE 2020-01-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 10:43:19 AM
Creation date
1/13/2020 10:37:42 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3530
Tenant Name
COCOON HOUSE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
292
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHGC Calculation ENV-SHGC <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2.R3,&R4 over 3 stories and all R1 Revised Jun 2016 <br /> Project Title: Cocoon House Youth Center Date 10/06/2017 <br /> % 17.5 k Max.Target: 30% For Building Department Use <br /> Fenestration Area asgross above-grade wall area 9 <br /> Skylight Area as%gross roof area 0.9% Max.Target: 3% <br /> Vertical Fenestration Alternates: None Selected on ENV-SUM <br /> Notes:1-Proposed vertical fenestration and skylight areas entered in ENV-SHGC must match proposed <br /> fenestration areas in ENV-UA. <br /> 2-If Target Area Adjustment is required per ENV-UA,then target areas will be automatically <br /> adjusted in ENV-SHGC.Refer to Target Area Adjustments worksheet for this calculation. <br /> 3-Fenestration assembly SHGC shall be the manufacturer's NFRC product rating.or shall be the <br /> default value per Section C303.1.3. <br /> 4-Fenestration that separates conditioned space from a non-conditioned space shall be included <br /> in this worksheet.Enter target SHGC values for this fenestration under proposed SHGC,so it <br /> is neutral to the calculation. <br /> Skylights Proposed SHGC Target SHGC <br /> Sch.ID Provide SHGC source and fenestration schedule ID SHGC x Area(A) =SHGC x f SHGC x Area(A)= SHGC x A <br /> Skylights CPD#MIL-A-218-01143-00002 0.34 127 43 0.35 127 44.5 <br /> SHGC 0.35 <br /> Skylight Totals 127.0 43.2 127.0 44.5 <br /> All Non-North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF <br /> Sch.ID Provide SHGC source and fenestration schedule ID PF SHGC x Area(A)=SHGC x A Category SHGC x Area(A)= SHGC x A <br /> Fixed Vinyl CPD#.VPI-A-18-01115-00001 0.27 77 21 PF<0.2 0.40 3140 1256.0 <br /> Operable/A <br /> caning CPD#:VPI-A-20-01199-00001 0.22 376 83 0.25PF<0.5 0.48 <br /> Operable/c 0.22 1273 280 0.64 <br /> asement CPD#:VPI-A-29-02206-00001 PF>_0.5 <br /> Double <br /> Pane metal 2015 WSEC Table C303.1.3(3) 0.40 223 89 ++If projection factor(PF)credits are <br /> applied to the proposed design,Target <br /> Fixed SHGC will sum fenestration area by PF <br /> storefront NFRC CMA#P-KAW-14188 0.34 299 101 category. <br /> Fixed <br /> Aluminum 0.34 668 227 <br /> window CPD#:MIL-A-148-03435-00002 <br /> Oper <br /> aluminum/c 0.29 110 32 <br /> asement CPD#:MIL-A-187-03898-00001 <br /> Hollow <br /> metal door NFRC RPT#:A8255.01-116-45 0.38 114 43 <br /> +If PF credit is applied,then vertical fenestration Non-North Window Totals 3140.0 875.9 3140.0 1256.0 <br /> must be entered in the correct table according to <br /> orientation. If credit is not applied then all vertical <br /> fenestration can be entered in either table. <br /> [ North Vertical Fenestration+ Proposed SHGC Target SHGC++ <br /> PF SHGC x Area(A)=SHGC x A PF SHGC x Area(A)= SHGC x A <br /> Sch.ID Provide SHGC source and fenestration schedule ID Category <br /> PF<0.2 0.53 <br /> 0.2<PF<0.5 0.58 <br /> PF>_0.5 0.64 <br /> ++If projection factor(PF)credits are applied <br /> to the proposed design,Target SHGC will <br /> sum fenestration area by PF category. <br /> North Window Totals <br /> TO COMPLY-The Proposed Total SHGC x A Area SHGC x A Area SHGC x A <br /> shall not exceed the Target Total SHGC x A. Total(Skylight+Window) 3267.0 919.1 3267.0 1300.5 <br /> Component Performance Compliance (SHGC) SHGC COMPLIES <br />
The URL can be used to link to this page
Your browser does not support the video tag.