Laserfiche WebLink
Cocoon House (GGLO Design) R U , ' 'N G <br /> Residential Envelope Parameters <br /> SPU#17-004/REVIII7-015 <br /> Opaque Constructions: <br /> Roof Assemblies: <br /> Flat deck roof (R03/A-602) R-Value Source <br /> Wood Framed Attic,R-38 min U= 0.014 Custom upper roof calc. <br /> Sloped deck roof (R03/A-602) R-Value Source <br /> Roof deck R-38 rigid U= 0.025 2015 WSEC Table A102.1 <br /> Wall Assemblies: <br /> Wood frame wall(D01/A-601) R-Value Source <br /> Standard 2 x 6 Wood studs,R-21 Batt Insulation U= 0.057 2015 WSEC Table A103.3.1 (5) <br /> Wood frame wall(D03/A-601) R-Value Source <br /> Standard 2 x 8 Wood studs,R-25 Batt Insulation U= 0.051 2015 WSEC Table A103.3.1 (8) <br /> Mass Stem Wall w/R-10 Rigid+R-5(2x8 curb detail) R-Value Source <br /> Mass Wall,R-10 Cl+R-5 Z-girt <br /> Exterior air film 0.17 2015 WSEC Table A101.5 <br /> R-10 Rigid C.I. 10 Manufacturer's Data <br /> 6"Concrete Wall 0.375 2015 WSEC Table A101.5 <br /> R-5 Rigid w/Z-girts 3.6 ASHRAE 1365-RP, Detail 02 <br /> PT furring strips 0.45 2015 WSEC Table A101.5 <br /> Interior air film 0.68 2015 WSEC Table A101.5 <br /> Total R-Value= 15.28 <br /> U= 0.065 <br /> 5 <br /> Mass Stem Wall w/R-5 Rigid (2x8 curb detail) R-Value Source <br /> Mass Wall,R-5 Z-girt <br /> Exterior air film 0.17 2015 WSEC Table A101.5 <br /> 6"Concrete Wall 0.375 2015 WSEC Table A101.5 <br /> R-5 Rigid w/Z-girts 3.6 ASHRAE 1365-RP,Detail 02 <br /> PT furring strips 0.45 2015 WSEC Table A101.5 <br /> Interior air film 0.68 2015 WSEC Table A101.5 <br /> Total R-Value= 5.28 <br /> U= 0.190 <br /> Slab Edge Assemblies: <br /> Insulated Slab on Grade(A501) R-Value Source <br /> 2ft vertical R-10 rigid F= 0.540 2015 WSEC Table A106.1 <br /> Floor Assemblies: <br /> Floor over Breezeway(F03/A-602) Source <br /> Wood I-Joist,R-30 Batt insulation U= 0.040 2015 WSEC Table A105.1(3) <br /> Opaque Door Assemblies: <br /> Flush Metal Door R-Value Source <br /> Foam Insulated Steel Slab,Steel Frame U= 0.370 2015 WSEC Table A107.1(1) <br />