3003 W CASINO RD 2018 BLDG 40-03 Plans 2022-11-10
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-03
>
Plans
>
3003 W CASINO RD 2018 BLDG 40-03 Plans 2022-11-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 11:28:29 AM
Creation date
1/13/2020 11:28:44 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-03
Permit
B1811-030
Year
2018
Notes
ACCESS SELECTIVE DEMO CMU WALLS ADN BUILD BACK PLUMBING WALLS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4' <br /> .{ <br /> (2)4"C, EACH W/3 SINGLE CONDUCTOR � I <br /> 350 MCM, 15KV SHIE�DED CABLES & (1 ) EG E I �I D . <br /> 4/0 BARE CU GND. CONDUCTOR 12.47KV FEEDER FROM � <br /> 4/0 BARE EXISTING 1000KVA UNIT SEE SHEET EO FOR SYMBOLS AND LEGEND. <br /> cu cR�. CONDUCTOR SUBSTATION IN BLDG 40-01 <br /> TO BLDG. GROUND Y�—"�- � FDR-1 -1 TYPE RATING CONDUIT CONDUCTORS PER CONDUIT <br /> TO SUBSTATION �1 -3 TO SUBSTATION �1 -5 QTY SIZE PHASE NEUTRAL GROUND I.G. <br /> �: <br /> VAULT (V03-1) 15KV SPLICE 80X � _ _ _ i VAULT (V03-3) E5 600A 2 3 1/2" 3–�350kcmil �350kcmil � -4:' � <br /> SEE DWG. 40-03–E4 SEE DWG. 40-03–E4b – – <br /> (#00005316) FDR-2-1 (#00005318) � <br /> _ _ _ E� 600A 2 3" 3–#300kcmil �300kcmil – – � <br /> 15KV-3 C-350 MCM SHIELDED FDR2-1 FDR1 -1 � <br /> INTERLOCKED ARMOR CABLE 1 -3-2 1 -3-1 E8 600A 2 3 1/2" 3–#350kcmil – – – <br /> 15KV H5 400A 1 3" 3–�500kcrnil – – – . <br /> j INTERRUPTER � <br /> SWITCHES M1 225A 1 2" 3–�4/0 – <br /> � <br /> M2 225A 1 2" 3–�4/0 �4/0 – – " <br /> 80E ' ' <br /> � I M8 225A 1 3" 3–�4/0 �4/0 � <br /> I � � – – . <br /> 12.47KV M9 225A 1 2 1/2" 3–�4/0 �4/0 �4 <br /> — p <br /> _ �� 1000/1333KVA S U B STAT 0 f� � 1 - 4 M11 225A 1 3" 3– 4 0 – – – � � <br /> - - - - - - - - - O � � <br /> 480Y/277V , �A U �T (�0 � - 2 ) » <br /> P� 175A 1 2 3–�2/0 �2/0 <br /> � POWER �B � SPACES: NONE , <br /> < <br /> � MONITOR P8 175A 1 2 1/2" 3–�2/0 �2/0 " �:f <br /> A AS • . <br /> COOLING FAN -�---� R1 225A 1 1 1/2" 3–�1 – – – � <br /> I <br /> �0---- VS T —� I R7 125A 1 2" 3–#1 – – <br /> I � <br /> � 1600AF � 100A _ _ _ � <br /> 1600AT ) T1 1 1 1/2" 3–�2 . <br /> 1200A, 480/277V, 3�, 4W <br /> � I T8 100A � � " 3–#2 – – – <br /> I �� <br /> I A6 A5 A4 A3 A2 A1 U1 80A 1 1 1/2" 3–�4 – – – " �� <br /> � TI E ' � <br /> � � � � � � � I , <br /> 600AF 600AF 600AF 800AF 600AF 600AF 1600AF --- (3) #500MCM EA. PHASE GE�IERA� NOTES <br /> � 600AT ) o00AT ) 600AT ) 600AT ) 400AT ) 600AT ) 1200AT ) (4) �300MCM NEUTRAL <br /> � A �, A �, A �, A �, A �, A � A �, . � <br /> 1 . ALL EQUIPMENT , RACEWAYS, AND CONDUCTORS ARE <br /> - - - - <br /> - - - - <br /> EXISTING, UNLESS OTHERWISE NOTED. <br /> TO SUBSTATION #1 -3 BUS TIE TO SUBSTATION �1 -5 2. PANEL ID PREFIX: 4: 480V � �� <br /> VAULT (V03-1) 1 -3 1 -4 1 -5 VAULT (V03-3) 3: 480Y/277V � : , <br /> SEE DWG. 40-03–E4 SEE DWG. 40-03–E4b � <br /> (#00005316) �` E8 __�__ E7 E7 2: 208/120V <br /> r � (�00005318) <br /> 1000A, 4P, FULL NEUTRAL <br /> 408Y/277V BUS DUCT j j 3. (�) IN PANEL SYMBOL INDICATES BRANCH � <br /> I I CIRCUIT. �e. (7) 7abc OR 7,9,11 <br /> I I E5 E5 E5 4. TRANSFORMERS DELTA–WYE UNLESS <br /> O O O - <br /> I I OTHERWISE NOTED. <br /> j O O O j 3V03– 3V03– 3V03– 5. CONTRACTOR TO UPDATE ONE LINE WITH EXISTING <br /> 2UD10–D 2UA9-1 D 2UA9–D EQUIPMENT IN AREA OF NEW CONSTRUCTION ` <br /> � 125HP 125HP 25HP� BUS DUCT BUS DUCT � � <br /> I � 600A MCB 600A MCB 600A MCB CURRENTLY NOT SHOWN ON DRAWIf�1G. • -t' <br /> �__�.��._____� N0. 4 N0. 3 12 13 11 7 5 6 3 8 1 13 5 � <br /> MATERIAL TEST SYSTEM 2-1/2"C, (4)�4/0 � <br /> M8 RE �ERE CE DRAW GS ,� <br /> H5 <br /> M11 <br /> M1 _ _ 2"C, 3#250kcmil C <br /> � CO �ISTRUCT0 �1 �IOTES <br /> MCC �2 4V03– M8 MCC �4 <br /> 2D11 � � TO ATS XE3V03-2A9. 1�j PROVIDE 50A-2P CIRCUIT BREAKER FOR <br /> I I TEMPORARY CONSTRUCTION POWER. � <br /> 225A 225A MCB SEE DWG 40-003–E5. ; <br /> 5 " � <br /> U1 R1 U1 R7 .� <br /> � I I <br /> 3V03– 3V03– 3V03– 3V03– ► 200A 200A I T1 <br /> 2UD10A 2C9 2C10 3C9 ) 3P ) 3P <br /> 200A MCB 225A MCB 225A MCB 225A MCB � � <br /> O O �� <br /> T8 � I 100HP 100HP I � " <br /> r 45K VA T 45KVA r 75KVA T 75KVA T 75KVA " � <br /> � SPRAGUE HYD. TEST <br /> P7 P7 M9 � M9 M8 M8 BENCH PUMPS M2 . <br /> O O O O � O . <br /> 2V03– 2V03– 2V03– 2V03– 2V03– 2V03– F 2V03– <br /> 2D11 2UD10 2UD8 2UD8–A 2C9 2C9-1 2A9 <br /> 200A MCB 200A MCB 200A MCB 200A MCB 225A MCB 200A MCB 225A MCB � � <br /> �. <br /> � � � � � • . <br /> � G I N � E � $ W5741115 <br /> S U B S TAT 0 N # 1 - 4 (�� � - 2 ) - 0 N E E D A G R A Nl 1101 2nd Ave.,Suite 400�Seattle,WA 98101 PHASE 3 RENOVATION PACKAGE R r. <br /> SCALE: NTS ph 206.623.0717�fiax206.624.3775 IFC SU��IT�TAL � <br /> coffman.cnm � <br /> LASTING creativiry�resWts�relatlonships 10.0�.18 a <br /> � <br /> r <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATF J�l DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL c DATE �. • <br /> �1 • V�� ACCEPTABILITY J. OMALLEY SU�S�ATION #1-4 (V03-2) ONE-LINE DIA�RAM W5741115 I 10.08.18 � <br /> A OMIT REMOVAL OU VM AND AM HSG JSH 04.27.93 E GENERATOR SYSTEMS - GENSET �17 - RECORD 17631698 SAZAN KWA 04.13.16 ��'�,�F ��'��5��'I,� � THIS DESIGN AND/OR CHECKED � <br /> � Gj ,� SPECIFICATION IS APPROVED SHEET � <br /> B AS-BUILT (HARRIS GROUP) HGI/MCN PRH 10.15.98 F WORKPLACE ENVIRONMENT INVESTMENT W5741115 CEI PWJ 10.08.18 � � `�� � ��. � APPROVED BY DEPT. OATE ENGINEER TITLE WORKPLACE ENVIRONMENT INVESTMENT � <br /> C �. <br /> C TEAGUE OFFICE RELOCATION 11653372 WH SRM 09.26.11 CHECKED c . .. <br /> APPROVED �U!��� �� �O"��0� JOB N0. COMP N0. � <br /> � � �,w 17631698 <br /> - RECORD DRAWWG 11653372 WH SRM 03.01.12 � �� `�' n <br /> D AS-BUILT FROM VAULT CLEANING RED-LINES DM/KR KR 01.18.12 °��s��=�sTC���1� APPROVED ELECTRICAL MASTER EVERETT, WA °wc No. 40-003–E4A • <br /> �n�d��n�Q � <br />