My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4518 SEAHURST AVE Geotech Report 2022-10-25
>
Address Records
>
SEAHURST AVE
>
4518
>
Geotech Report
>
4518 SEAHURST AVE Geotech Report 2022-10-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2022 1:08:34 PM
Creation date
1/14/2020 7:19:11 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAHURST AVE
Street Number
4518
Address Document Type
Geotech Report
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Naranjo JN 15186 <br /> May 18,2015 Page 6 <br /> height,a uniform lateral pressure equal to 10 psi times the height <br /> of the wall should be added to the above active equivalent fluid <br /> pressure. <br /> The design values given above do not include the effects of any hydrostatic pressures behind the <br /> walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent <br /> foundations will be exerted on the walls. If these conditions exist, those pressures should be added <br /> to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need <br /> to be given the wall dimensions and the slope of the backfill in order to provide the appropriate <br /> design earth pressures. The surcharge due to traffic loads behind a wall can typically be <br /> accounted for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid <br /> density. Heavy construction equipment should not be operated behind retaining and foundation <br /> walls within a distance equal to the height of a wall, unless the walls are designed for the additional <br /> lateral pressures resulting from the equipment. <br /> The values given above are to be used to design only permanent foundation and retaining walls <br /> that are to be backfilled, such as conventional walls constructed of reinforced concrete or masonry. <br /> It is not appropriate to use the above earth pressures and soil unit weight to back-calculate soil <br /> strength parameters for design of other types of retaining walls, such as soldier pile, reinforced <br /> earth, modular or soil nail walls. We can assist with design of these types of walls, if desired. The <br /> passive pressure given is appropriate only for a shear key poured directly against undisturbed <br /> native soil, or for the depth of level, well-compacted fill placed in front of a retaining or foundation <br /> wall. The values for friction and passive resistance are ultimate values and do not include a safety <br /> factor. Restrained wall soil parameters should be utilized for a distance of 1.5 times the wall height <br /> from corners or bends in the walls. This is intended to reduce the amount of cracking that can <br /> occur where a wall is restrained by a corner. <br /> Wall Pressures Due to Seismic Forces <br /> The surcharge wall loads that could be imposed by the design earthquake can be modeled <br /> by adding a uniform lateral pressure to the above-recommended active .pressure. The <br /> recommended surcharge pressure is 8H pounds per square foot (psf), where H is the <br /> design retention height of the wall. Using this increased pressure, the safety factor against <br /> sliding and overturning can be reduced to 1.2 for the seismic analysis. <br /> Retaining Wall Backfill and Waterproofing <br /> Backfill placed behind retaining or foundation walls should be coarse, free-draining <br /> structural fill containing no organics. This backfill should contain no more than 5 percent silt <br /> or clay particles and have no gravel greater than 4 inches in diameter. The percentage of <br /> particles passing the No. 4 sieve should be between 25 and 70 percent. If the native sand <br /> is used as backfill, a drainage composite similar to Miradrain 6000 should be placed against <br /> the backfilled retaining walls. The drainage composites should be hydraulically connected <br /> to the foundation drain system. <br /> The purpose of these backfill requirements is to ensure that the design criteria for a <br /> retaining wall are not exceeded because of a build-up of hydrostatic pressure behind the <br /> wall. Also, subsurface drainage systems are not intended to handle large volumes of water <br /> from surface runoff. The top 12 to 18 inches of the backfill should consist of a compacted, <br /> relatively impermeable soil or topsoil, or the surface should be paved. The ground surface <br /> must also slope away from backfilled walls to reduce the potential for surface water to <br /> GEOTECH CONSULTANTS,INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.