18
<br /> A g � A5.1
<br /> D
<br /> o GENERAL NOTES�
<br /> 4 17 1. ALL EXISTING BUILDING COLUMNS, EXTERIOR WALLS, EXTERIOR WINDOWS, AND
<br /> STRUCTURAL MEMBERS TO REMAIN, UON. �
<br /> -14 __ ' 9 ��
<br /> --- - -
<br /> ___
<br /> __
<br /> 14 2. NEW RESTROOM(S) TO BE FULLY ACCESSIBLE PER THE PROVISIONS OF ANSI ""���
<br /> - - . ___ _
<br /> 0 10 �p � � A117.1 SECTION 603 AS SUMI�MRIZED ON SHEEf T1.2.
<br /> 7 5 ^
<br /> � � � �'err� Pc�w�r_
<br /> 6 � 15
<br /> KEY NOTES� O
<br /> UNISEX RESTR40M ELEVATICJNS RESTROOM ACCESSORY MANUFACTURER: BOBRICK, CLASSIC SERIES, UON.
<br /> 5 STAINLESS STEEL WITH SA71N FlNISH
<br /> �/4" _ �'-o" a r c h i t e � t s
<br /> SEE T1.2 FOR MOUNTING HEIGHTS AND RELATIONSHIPS �• WATER CLOSET. REFER TO 604/T1.2.
<br /> FLUSH CONTROLS SHALL BE ON OPEN SIDE QF THE WATER CLOSET. 2505 Third Avenue
<br /> Suite 324
<br /> �8 B 2. SINK IN COUNTER TOP. REFER TO 606/T1.2. Seattle, WA 98�21
<br /> A5.1 5'-0" 2'-11" 2'-11" 2'-11" 14
<br /> A
<br /> CLEAR CLEAR CLEAR CLEAR A5'� 3. WALL HUNG SINK. REFER TO 606/T1.2.
<br /> C 206.720.700'I phone
<br /> 4. SURFACE MOUNTED MIRROR. FULL WIDTH OF COUNTERTOP X36. REFER TO 206.720.2949 fax
<br /> 603/T1.2.
<br /> www.crafta rch itects.com
<br /> 8 8 8 a 2'-� � 5. SURFACE MOUNTED TOILET PAPER DISPENSER MOUNTED BELOW GRAB BAR
<br /> 14 4 9 MOUNTING ZONE. REFER TO 604.7/T1.2.
<br /> __ __ _
<br /> 6. SURFACE MOUNTED SANITARY NAPKIN DISPOSAL. REFER TO 606/T1.2. N �
<br /> `.� �� 10 c� � o � � __
<br /> � 7. SUR
<br /> � FACE MOUNTED TOILEf SEAT COVER DISPENSER. REFER TO 6Q6/T1.2. W
<br /> MAX ALLOWABLE STRESSES: VERTICAL OR 5 �.^
<br /> 1 1 � ,,,� .� ��I vJ
<br /> HORIZONTAL FORCE OF 250 POUNDS 6 1 �`� I 15 8. TOILET PARTITION, OVERHEAD BRACED. REFER TO 604/T1.2.
<br /> APPLIEQ AT ANY POINT ON THE GRAB BAR, _ Q
<br /> FASTENER MOUNTING DEVICE OR ._ __ - - __ T
<br /> 9. RECESSED PAPER TOWEL DISPENSER/WASTE RECEPTACLE, 1YP. REFER TO '�
<br /> - SUPPORTING STRUCTURE. � z 606/T1.2. �,
<br /> - �
<br /> 10. SURFACE MOUNTED GRAB BARS PER ICC/ANSI A117.1 SECTIONS 604 AND �
<br /> � PARTITION AS SCHEDULED WOMEN'S RESTR40M ELEVA •
<br /> TIONS 609, SEE ALSO DEfAIL 19/A5.1. PROVIDE BLOCKING AS REQUIRED. � Q �
<br /> a �
<br /> " 4' ,,4�. _ ,�-o„ o
<br /> SEE T1.2 FOR MOUNTING HEIGHTS AND RELATIONSHIPS 11. FLOOR DRAIN WITH TRAP PRIMER. 12" SQUARE SECTION OF FLOOR TO SLOPE � W > N
<br /> � �/2„ TOWARD FLOOR DRAIN. � J �
<br /> � � �
<br /> 1/4" DIA SHEET MEZAL SCREWS TO 12. WALL HUNG URINAL. REFER TO 605/T1.2. W �
<br /> MEfAL BLOCKING/BACKING O > �
<br /> 18 13. MANEUVERING CLEARANCES / CLEAR FLOOR SPACE REQUIRED AT FIXTURE. Q Q �
<br /> 1 1/2" DIA GRAB BAR A5,1 REFER TO 305, 404, 604/T1.2., TYP. � �
<br /> {1 1/4" MIN TO 2° MAX OUTSIDE DIA) � ^
<br /> C p Q �' Q
<br /> 14. WAINSCOT, iYPICAL ALL (4) WALLS, UNO OR SHOWN WITHOUT WAINSCOT IN � �
<br /> Q N Z ELEVATION. �
<br /> � ♦^
<br /> `D � � 8 15. WHITE INSULATION/COVER, SEE 606.6/T1.2. � � v, �
<br /> i PROTRUDING ELEMENT Z r W
<br /> 14 16. SIGNAGE WITH BRAILLE, REFER TO 703/T1.2 W � >
<br /> - SINGLE OCCUPANCY: TRIMCO, 529, BLUE, MENS: TRIMCO, 527, BLUE,
<br /> M 16 GA METAL STUD BLOCKING W/ (1) --- - - _ �
<br /> ____ _ --- - - �
<br /> --- - -- - -
<br /> ---- ---- -
<br /> CLIP TOP AND BOTfOM �d � - -
<br /> WOMENS: TRIMCO, 528, BLUE Z � � W
<br /> OR 3/4" PLYWOOD BACKING � 10
<br /> 5� ��� 17. INSTALL RECESSED PAPER TOWEL DISPENSER FLUSH TQ GWB, PRIOR TO TILE. �
<br /> PLAM, FRP, OR CERAMIC TILE OVER INSTALL TILE TIGHT TO DISPENSER. FlNISH EXPOSED EDGE OF TILE WITH
<br /> WATER-RESISTANT GWB BRUSHED ALUMINUM TRIM CAP.
<br /> OR PREFABRICATED SHOWER MODULE W
<br /> __ - ._ __ _ _- �!
<br /> __.
<br /> _ __ _ _ _
<br /> _ __
<br /> 19 3,. _ ,�-o��
<br /> R DETAIL _ _ _ --
<br /> �
<br /> �
<br /> 14 O
<br /> A5.1 2'-11° 5'-0"
<br /> BRUSHED ALUMINUM A B CLEAR CLEAR C,ON3ULTANT
<br /> TRIM CAP
<br /> » 1'-11"
<br /> �--- ---� 9 4 O O 8 8
<br /> i �
<br /> ��,
<br /> � 7 10
<br /> PIAN SECTION THRU � -
<br /> `� TOILET ACCE�SnRY �5 I 2 2 2 ❑ 1
<br /> �- � O �
<br /> TILE, PER FINISH o �
<br /> SCHEDULE
<br /> �- 70�2
<br /> REGISTERE�
<br /> 4 COVE BASE MEN'S RESTROOM E - "R�"'TE�T
<br /> WHEN AVAILABLE 3 LEVATIONS
<br /> 1/4" = 1'-0"
<br /> SEE T1.2 FOR MOUNTING HEIGHTS AND RELATIONSHIPS
<br /> �E OF �H�NG�OIY
<br /> os�-� . .
<br /> AT TILE FL�OR 21,_r I Submittals/Revisions:
<br /> SECTI�N � TILE �'-2 ��� � �A 6 Q 5 � _ FOR PERMIT 08/08/2018
<br /> 18 ; ,
<br /> � �� _ ,�-o�� �
<br /> v:
<br /> _ �:: .�._, - :. .
<br /> s 9 5 t FOR BID 08/16/2018
<br /> _,. _ _ _�> _r_m. _ .� ..� __:... �A5.1 "
<br /> �� � � ,' � ;
<br /> `" REs RooM p � - - --__� ; � ` �s � I Fo. ` 10 � `; �i PER�IIT CORRECTION 10/22/2018
<br /> �� 116 �'' JANITOR �.� �i ;` 11 ` o0
<br /> 3/4" SOL1D SURFACE BACKSPLASH � ,
<br /> 2'-0" U.N.O. W/ FINISH TO MATCH COUNTERTOP 3 - t -- - - = G
<br /> � r
<br /> N 113 �
<br /> 3/4" 2 1/2" X 2 1/2" X 1/4" STEEL ANGLE, ��
<br /> : � � A5.1 RESTROOM t3 3
<br /> -- - �
<br /> CONTINUOUS FULL WIDTH OF COUNTERTOP = ` - -- - -- - B _ i�20 I •
<br /> �' � - 13 i
<br /> i �� _ ._
<br /> � 3/4" SOLID SURFACE COUNTERTOP W/ �, FD. 11 8 i � ,
<br /> �-� i _ i i
<br /> �, UNDERMOUNT SINK. FINISH PER FINISH �_. 5 �
<br /> J R i
<br /> � � PLANS, EASED EDGE , , � I - -
<br /> a °�r z �� 1 6
<br /> . �
<br /> ���� 5 �i � 8 � � g ;� 16 ��
<br /> o _ _-- � � � 8� � � 2 '� � : 121 3 �
<br /> Y �� � . . � � � � ,, �
<br /> __. __ . ,- O . , .
<br /> ______ ---
<br /> - 3/4" SOLID SURFACE APRON W/ FlNISH • t2 0 _-o__ _ _ o__ __ , _ ;
<br /> � li � _ 10 • ' ���_� � � �-: _
<br /> '' A
<br /> � Y;
<br /> � I , TO MATCH COUNTERTOP � � . ° ° ° 16 17 5 j ��
<br /> \ � .: � . ;. : .:_�_. o ..o.:,, 11 �
<br /> � -- ` : ` o -� ':r{ - Sheet Title: INTERIOR ELEVATIONS
<br /> 0
<br /> � � � ���; 10 � 1 � ��` � g � 5.1 �' �� �
<br /> ��� 0 1 0 0 0 � _ _� - �o -- 13 , � OPP. ' 1
<br /> W li � '�, M CONCEALLED SUPPORT PER DETAIL 18/A6.1 E , & DETAILS
<br /> Z � ' S FD 11 5 i 5 5 2 a �
<br /> QN � � PIPE INSULATION KIT s 6 6 � 6 g I ; � 9 �Q 6 5 = Date: 0$/08/201 S
<br /> i � � � � �� 8 8 8 s �
<br /> � - 4�.0
<br /> z
<br /> : , Design: .
<br /> � o � � _� `
<br /> � � �
<br /> Z ,; N g�, -- _ __ _ _ , - - - _
<br /> w � � N �
<br /> - - : 7 B �3 Drawn:
<br /> a� � COMPLIANCEEE SPACE REQUIRED FOR ADA �� WOMEN'S I A A5.1 N .
<br /> Pro ect No:
<br /> �, ' � J
<br /> o -
<br /> o ��
<br /> o� ESTROOM I
<br /> ENLARGED RESTROOMS �$-a�fi.o5
<br /> „� , ,6 1
<br /> � - - �/4" _ �'-o" Approved:
<br /> � �� ' � �'�
<br /> E -__= r fi t ' r ar� ,g.�t t t
<br /> N :=.z ^, ...: ._... . .,4..'....
<br /> `
<br /> ...s � .r ,„.. :. . -, .;
<br /> �
<br /> ,., .. ...-., . ,... . .�.
<br /> �
<br /> � � KCR
<br /> Building No:
<br /> o N
<br /> � SECTION LAVA � � -
<br /> N 14 TORY COUNTER ENLARGED RESTROOM ������� F�� ���
<br /> 0 2 � Sheet No:
<br /> �" _ �'-o"
<br /> 1/4" = 1'-0" ■
<br /> COPYRIGHT CRAFT ARCHITECTS 2018
<br />
|