Laserfiche WebLink
• <br /> Si"mple'Heating System Size: Was ---mon State <br /> This heating system sizing calculator is based,e_.Prescriptive Requirements of the 2012 Washingto Energy Code(WSEC)and ACCA <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling <br /> loads. <br /> The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of <br /> 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, <br /> some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension <br /> Program at(360)956-2042 for assistance. <br /> Project Information ._ .; <br /> O - _. Contact Information <br /> Planr25.., <br /> Heating System Type: <br /> To see detailed instructions for each section,place your cursor on the word'Instructions". <br /> Design Temperature <br /> In-,tructio-1=, =.Y Design Temperature Difference(AT) 46 <br /> Lynnwood 71r A T=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 2,435 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) . 8.5 20,698 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions 0.30 438 131.40 <br /> Insulation <br /> AtticU-Factor X Area = UA <br /> Instructions R�9 3' 0.026 996 25.90 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor Area UA <br /> Instructions <br /> No Vaulted Ceilings in this project. <br /> Above Grade Walls(see Figure 1) U-Factor Area UA <br /> Instructions y,u,. .. "" <br /> -21 0.056 2,500 140.00 <br /> Floors U-Factor Area _ UA <br /> Instructions `-30 'j"' 0.029 470 13.63 <br /> R <br /> Below Grade Walls(see Figure•p U-Factor Area UA <br /> Instructions <br /> No Below Grade Walls in this project. <br /> Slab Below Grade(see Figure 1) . .. F-Factor Length UA <br /> Instructions <br /> No Slab Below Grade In this project. <br /> Slab on Grade(see Figure 9. F-Factor Length UA <br /> instructions 0.540 82 44.28 <br /> R-10 Perimeter 7; <br /> Location of Ducts <br /> Instructions _ Duct Leakage Coefficient <br /> Unconditioned Space 1.10 <br /> • <br /> Sum of UA 355.21 <br /> Envelope Heat Load 16,339 Btu/Hour <br /> Figure 1. Sum ofuAXAT <br /> Air Leakage Heat Load 10,283 Btu/Hour <br /> 'tea' VolumeX 0.6XOTX.018 <br /> EMI Building Design Heat Load 26,622 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 29,284 Btu I Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 40,998 Btu/Hour <br /> Building and Duct Heal Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (.0\/`7/01/13) <br />