My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1724 W MARINE VIEW DR 2018 Utility Plans 2022-10-27
>
Address Records
>
W MARINE VIEW DR
>
1724
>
Utility Plans
>
1724 W MARINE VIEW DR 2018 Utility Plans 2022-10-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/27/2022 11:11:18 AM
Creation date
1/17/2020 1:36:48 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
1724
Permit
PW1809-004
Year
2018
Notes
UTILITY DRAWINGS
Address Document Type
Utility Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� , _ _ __ . _ _ _ __ <br /> _ __ <br /> KEYED NOTES <br /> EXISTING SOUTH MARINA O1 PROVIDE PVC COATED GALVANIZED RIGID STEEL CONDUIT. <br /> SUBSTATION SWITCHBOARD <br /> � � 2O RE-LABEL EXISTING SEWER PUMP CIRCUIT BREAKER AS <br /> I I SPARE. <br /> � 2 3 3 PROVIDE 40 AMP 3-POLE CIRCUIT BREAKER, LABEL 'SEWER <br /> I 40A I O PUMP' MATCH AIC RATING OF EXISTING PANEL. <br /> , <br /> � - - - - - J 4 REMOVE EXISTING SEWER PUMP SUPPLY CONDUCTORS, <br /> SWITCHBOARD S.Sub 1000 A BUS SECTIONS: 1 FLOOR MOUNTED O CLEAN MANDREL AND PROVfDE NEW CONDUCTORS PER <br /> 480/ 277V 3 PHASE 4 WIRE 1000 A MCB LUGS: SINGLE NEMA: 3R T ONE-LINE DIAGRAM IN EXISTING RACEWAY. <br /> LOCATION: South Marina Sub 22,000 AIC FEED: Service NUMBER OF POLES: 72 H LE <br /> NEW <br /> CKT TYPE SERVES C.B. KVA CONNECTED PHASE LOAD KVA C.B. SERVES TYPE CKT HANDHOLE 1Q <br /> 1 A SF Float 'A' 150/3 0.0 /3 2A �4 <br /> 1 B ---- --- 0.0 --- 2B <br /> 1 C ---- --- 0.0 --- 2C <br /> 3A SF Float 'B' 150/3 0.0 /3 4A 3#8, 1 #10G <br /> 3B ---- --- �•� --- 4B 60 AMP DOUBLE-THROW <br /> 3C ---- --- 0.0 --- 4C STAINLESS STEEL DISCONNECT 3#6, 1#10 <br /> 5A ---- /3 0.0 150/3 South Visitor's Float SF 6A <br /> 56 ____ ___ � � ___ ____ 6B PUMP GENERATOR <br /> 5C p.p --- ---- 6C CONTROL RECEPTACLE <br /> PANEL <br /> 2 7A MO Sewer Lift Station South 40 / 3 18.28 6.1 200/3 Float 'G' SF 8A <br /> 7B ---- <br /> --- 6.1 --- ---- $B CABLE PROVIDED WITH <br /> 7C ---- --- 6.1 --- ---- 8C PUMP <br /> 1 9A MO Sewer Lift Station South 20/3 0.0 300/3 Admin MAIN SF 10A <br /> gg ---- --- 0.0 --- ----Marina Office 10B <br /> 9C ---- --- 0.0 --- ---- 10C 6 . 6 . <br /> 11 A SF Float 'D' 150/3 0.0 /3 ---- 12A <br /> 11 B ---- --- 0.0 --- ---- 12B SEWER <br /> 11 C p.p --- ---- �2� PUMPS <br /> 13A SF Float 'C' 150/3 0.0 ---- 14A <br /> 13B ---- --- 0.0 <br /> ---- 14B ONE-LINE DIAGRAM 1 <br /> 13C ---- --- 0.0 ---- 14C NO SCALE E-2 <br /> 15A ---- /3 0.0 ---- 16A <br /> 15B ---- --- 0.0 ---- 16B <br /> 15C ---- --- 0.0 ---- 16C <br /> 17A /3 0.0 ---- �$A PROVIDE 60 AMP 480V 3� NEMA <br /> � 7B --- 0.0 ---- �$B 4X DOUBLE-THROW STAINLESS <br /> 17C --- 0.0 ---- 18C STEEL DISCONNECT SWITCH PROVIDE NEMA 4X <br /> 19A SF Float 'F' 150/ 3 0.0 ---- 20A STAINLESS STEEL <br /> 19B ---- --- 0.0 ---- 20B 480V 3� PUMP <br /> 19C p,p ____ 20C CONTROL PANEL <br /> 21 A SF Float 'E' 150/3 0.0 ---- 22A <br /> 21 B ---- --- 0.0 ---- 22B PROVIDE SEAL OFF CONDUIT FITfING AND <br /> ---- --- 0.0 ---- 22� 3/4" GRS CONDUIT INTRINSICALLY SAFE 1 -1/2" TO 1 -1/4" REDUCER PER NEC <br /> 21 C CIRCUIT SPACE 501 .15(A)(4) (TYPICAL OF 3) <br /> 23A SF Fioat 'H' 150/3 0.0 ---- 24A <br /> --- 0.0 ---- 24B PROVIDE 480V 3� GENERATOR 1 -1/2" LEVEL SENSOR(S) CONDUIT O1 <br /> 23B ---- INLET RECEPTACLE <br /> 23C ---- --- �•� ---- 24C 60 AMP 3-WIRE PIN & SLEEVE PROVIDE FACTORY THREADED CONDUIT ENTERING <br /> 6.1 6.1 6.1 CALCULATED LOAD 22.9 KVA (VERIFY WITH OWNER) WET WELL WITH INSULATED GROUNDING <br /> 42" MIN BUSHING, BOND CONDUITS AND METAL FRAMING <br /> MAXIMUM AMPS PER PHASE 27.5 AMPS WITH #6 BARE COPPER GROUND WIRE <br /> ' NOTES: GRADE <br /> � PROVIDE STAINLESS STEEL <br /> °. CABLE GRIPS AND HARDWARE <br /> J 1 . Existing Sewer-Lift Station Circuit Breaker, disconnect and label 'SPARE' 1 " POWER CONDUIT <br /> � <br /> � 2. Provide new 3-pole Circuit Breaker for Sewer-Lift Station. <br /> Z LIFT STATION WET WELL <br /> 0 3. Proide updated typed panel schedule. 18" MINIMUM (CLASS 1 DIV 1 <br /> a HAZARDOUS LOCATION) <br /> J <br /> �, TO EXISTING 1 -1/4" LEVEL <br /> � SWITCHBOARD PROVIDE CONTINUOUS <br /> M SENSOR(S) CONDUIT <br /> o CABLING FROM CONTROL _ <br /> �' 1 -1/4" PUMP CONDUITS PULL BOX PANEL TO LEUEL SENSOR(S) <br /> � 1 -1/2" PUMP <br /> N (TYPICAL OF 3) <br /> �, CONDUITS O1 PROVIDE CONTINUOUS <br /> � CABLING FROM CONTROL <br /> � PANEL TO PUMPS <br /> 0 <br /> 0 <br /> � <br /> � CON DU IT ROUTING D A R 2 <br /> � <br /> � NO SCALE E-2 <br /> � CALL 6EFORE YOU DIG RECORD DRAWI NG IF SHEET IS LESS THAN 22x34 <br /> � 1-800-424-5555 REDUCE SCALES ACCORDINGLY <br /> � <br /> U <br /> � PROJECT EN��NEER: S�A�E: pp RT O F EVE RETT DWG. N0. <br /> o S BARTKOSKE AS NOTED E�3 <br /> � E-� N <br /> � tak <br /> � DS BARTKOSKE JUNE 2018 S O U T H M A R I N A LI FT STAT I O N c�P No. <br /> O� D ASSOCIATES, INC, <br /> °� H�����°���.r � ,..: =: _---_ _ 2-0-0 50-01 <br /> o ENGINEERS-CONSULTANTS 1Q 5/30/19 DAS RECORD DRAWING DRAWN BY: CHECKED BY: A N D G R E A S E I N T E R C E P T 0 R S <br /> N RETT 2�31 WetmoreAvenue, suite3oo (206)243-5022 www.e�con.com C SMITH D SIATERLIS _ _ <br /> PROJECT <br /> a Everett, WA 98201 N o M R-S M 2 017 0 6 <br /> � P . 0 , BOX 538 425.493.5221 16300 CHRISTENSEN ROAD,STE 330 <br /> � SEATTLE,WA 98188 O 6/29/18 ISSUED FOR BID AND CONSTRUC710N APPROVED BY: <br /> EVERETT , WA 98206 www.otak.com E L E C T R I C A L D I A G R A M S 14 <br /> �' (425) 259-3 I 64 PROJECT 32492.�.�0 N0. DATE BY REVISION N0. DATE BY REVISION SHEET N0. OF 15 <br /> 0 <br /> d <br />
The URL can be used to link to this page
Your browser does not support the video tag.