Laserfiche WebLink
(E)200A RATED MSP (E)UTILITY METER <br /> 240V,3W, I-PRASE 240V,3W. 1-PHASE <br /> POINT OF CONNECTION WEET '1-ERICR WALL <br /> LOCATED: TO UTILITY <br /> (N)14-AC 3I 0M-Ii 1205 INSIDE GRID <br /> AXITEC 3 I OW MODULES (N)30A , N <br /> WITH P340 SOLAREDGE (N)SE. 5000H-US <br /> NON FUSIBLE AC <br /> OPTIMIZERS SOLAREDGE INVERTER Srnert energy today.* <br /> MAX AC OUTPUT=21 A DISCONNECT <br /> 1 STRING OF 14 MODULES (E)200A <br /> I ....M. SOLAR <br /> ... ... <br /> .,..,.., ,..., p le <br /> y ** LINE 1 1 <br /> 10 <br /> * * <br /> mem ImrillA •• • "At. , (ND--1B DC / <br /> ( v - L141 — ' ,---, ,---.. <br /> ..--. ,---, <br /> ". i co' 1 COOPER POINT <br /> 1 p-r• No NEMA.3R <br /> atlid 6-1 Eti *all <br /> U11) <br /> e-----s - <br /> •, <br /> E . .! . • •• • IN <br /> AC ,.....,) <br /> ,---, <br /> ---2,..--... <br /> • . i RD SW.STE i 40-290, <br /> ..--s, r•-•,. <br /> INVERTER DC INPUT VOLTAGE IS WITH INTEGRATED DC VISIBLE,LOCKAELE - OLYMPIA.WA 98502 <br /> REGULATED BY SOLAREDGE OPTIMIZER DISCONNECT AND EXTERNALLY OPERABLE p ...-Th. PHONE:360-537-4343 <br /> STRING VOLTAGE IS 380VDC NOMINAL vaTH AUTOMATIC RAPID 30A RATED <br /> 420VDC MAX INEC 690.71 SI-.71-DOLVN UPON AC GRID 240V.NEMA SR ...*-N. ."--", JENNI BLANKENSHIP <br /> DISCONNECT LIL LISTED <br /> 0,12211.3RP, (N)30A PROJECT MANASER <br /> INVERTER DC INPUT CURRENT IS <br /> REGULATED BY SOLAREDGE OPTIMIZER, L -1.G IIIIEIIIIIIIIIIIIIMIIIIIIII <br /> MAX STRING CURRENT IS <br /> 4340/380=11.42 AMPS <br /> WITH A MAX SHORT CIRCUIT OF 15A1NEC 4.340 DC KW <br /> 590.83 (E)EARTH <br /> - GROUND 5.000 KW AC RATING <br /> CENTRAL INVERTER SYSTEM <br /> 34 180 <br /> TILT AZIMUTH <br /> IIIIIIIIIIIIIIIIIII=1111 <br /> 2502 CHESTNUT DR <br /> EVERETT. <br /> WA 98201 <br /> NOTES TO ELECTRICIAN <br /> DAVID&MARY-ANN FISH <br /> INSTALL AP 30A GE BREAKER(THQL23O)FOR NE <br /> BACK FEED BREAKER. (360)42 1-8737 <br /> ------ - ------ <br /> 1 <br /> 1 25%OF INVERTER MAX AC OUTPU —T -----1 <br /> 1"-- MAX AC RESULT ----I WIRE/CONDUIT SCHEDULE _ <br /> I 25ii 1 _,,, OCIPD SIZE ' ---- <br /> OUTPUT'AMPS': ,s1,-1.P.., 1 <br /> ---- ---1 TAG ^DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT SIZE/TYPE <br /> r 21.00 1.25 26.25 30A _I -.--.-----4----- _ - ---------------- <br /> A ARRAY TO__ „JUNCTION BOX (2)#I 0 AWG PV WIRE&#6 AWG SOLID COPPER(G) FEE AIR DATE DESCRIPTION <br /> SERVICE LOAD CALCULATIONS NEC 705.12V(2)(3)(8) _ <br /> BACKIPED 1203i RULE-PER 705.12 r:>:(2,13.X.S) Wri ERE TWO SOURCES.ONE, UTILITY B -IBOX TO INVERTER (2)#I 0 AWG TIHN-2(1+& I)&(I)#8 AWG THHN-2(G) 1/2"EMT a LMFC <br /> AND THE OT'HER AN INVERTER.A.RE <br /> BUS RATING SOS MUT:FLIER!12014) RESULT LOCATED AT OPPOSITE ENDS OF A C INVERTER TO AC DISCO -(3)# 10 AWG THHN-2(L I,L2&N)&(I)#8 AWG THHN-2(G) 1/2"EMT <br /> — <br /> BUSBAR THAT CONTAINS LOADS,THE <br /> 200 1.20 240 D AC DISCO TO PROD.METER '(3)# 1 0 AWG THHN-2(L I,L2 8:N)&(1)#8 AWG THHN-2(G) 1/2"EMT <br /> --. SUM OF 125ii OF THE INVERTER(S) <br /> MAIN BREAKER SIZE INVERTER+1273E RESULT ---> OUTPUT CIRCUIT CURRENT AND THE E i PROD.METER TO EXIST BREAKER PANEL '(3)# 10 AWG THHN-2(L I,L2&N)&(1)#8 AWG THHN-2(G) 1/2"EMT <br /> RATING OF THE OVERCURRENT DEVICE - - --u------- - -.......—_, , _ , -• ______ DATE 10/9/19 <br /> 200 25.25 225..25 PROTECTING THE BUSBA.R SHALL NOT DRAWN: <br /> 240A>1=226.25A=OK ,____. EXCEED 1203i OF THE AMPACITY OF THE DRAWN BY: PD <br /> MAXIMUM SYSTEM DC VOLTAGE <br /> PHOTOVOLTAIC SYSTEM DISCONNECT -LABEL INFORMATION <br /> MODULE"'IOC FOR SiNGLE-MODU LE OPTIMIZER CONFIGURATIONS(WITH 80V AFC!CAP)(NEC 690.7 AND 690.Ii) ELECTRICAL <br /> ____ <br /> A OPTIMIZER MAKE AND MODELS SOLAREDGE P340 <br /> RATED MAX POWER POINTSINGLE <br /> 7CTAL'4 N10E:LILES X PMAX)/:.=-SOVDC 1 1.4 5 OPTIMIZER MAX DC OUTPUT CURRENT 15 .AMPS (FROM OPTIMIZERS SPECIFICATIONS) <br /> ,CUR:RENT <br /> 1 . C OPTIMIZER MAX DC OUTPUT VOLTAGE 46 <br /> VOLTS (FROM OPTIMIZERS SPECIFICATIONS) <br /> D MAX#OF OPTIMIZERS IN AN INPUT CIRCUIT 14 <br /> 8 MIN TO 25 MAX PER STRING LINE DIAGRAM <br /> I RATED MAX POWER POINT <br /> NOMINAL DC INVERTER INPUT VOLTAGE 350 <br /> I VOLTAGE E OPTIMIZER MAX DC INPUT VOLTAGE 48 VOLTS (FROM OPTIMIZERS SPECIFICATIONS) <br /> I F OPTIMIZER MAX DC INPUT POWER 320 WATTS (FROM OPTIMIZERS SPECIFICATIONS) , <br /> G AXITEC MODULE OC 40.01 VOLTS (FROM MODULE SPECIFICATIONS) <br /> AXIM:2M SYSTEM VOLTAkGE MAXIMUM INVERTER INPUT VOLTAGE ASO <br /> H S.OF MODULES PER OPTIMIZER 1 (FROM OPTIMIZERS SPECIFICATIONS) <br /> I I VOLTAGE CORRECTION FACTOR 1.12 <br /> , .,__, , __ ,,_ <br /> ,ShT.....T., -11,k-un-C t,RT-...N 1 4 OF STRING/5 X 1155 AMPS(IslAIK OLITPUT <br /> iso J MAXIMUM SYSTEM DC VOLTAGE 44.81 VOLTS moDuLE VOC X SOF MODULES PER OPTIMIEF_R X VOLTAGE CORRECTION FACTOR ---7•• <br /> CURRENT} <br /> L------ -- ---------------------- ------- ----- NOTE:"E"MUST BE LARGER THAN".)," 46k, >44.8 IV=OK THE VALUE CALCULATED MUST BE LESS THAN OPTIMIZERS MAX DC INPUT VOLTAGE <br /> t <br /> , <br />