My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4919 EVERGREEN WAY OLSONS 2018-01-02 MF Import
>
Address Records
>
EVERGREEN WAY
>
4919
>
OLSONS
>
4919 EVERGREEN WAY OLSONS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2020 2:22:25 PM
Creation date
1/23/2020 2:06:11 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4919
Tenant Name
OLSONS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
218
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
. ; . _ <br /> �. <br /> � <br /> Mr. Dave Matthews <br /> (Plan Check NB-44161) <br /> Apri129, 1994 <br /> Page 2 of 3 <br /> ✓8. Enclosed usuable ;�ace under interior stairways is required to be protected on the <br /> enclosed side as rev,uired for 1-HR fire-resistive construction. SecUon 3306(i). <br /> �9. Accessible doors shall have maneuvering clearances per Section 3106(j)3. This <br /> item applies to door 207. <br /> �10. Accessible check-out aisles shall be installed in accordance with Table No. 31-E <br /> and Section 3106(x). <br /> 1/11. Controls, operating mechanisms and hardware shall be accessible in accordance <br /> with Section 3106(c). Section 3105(d)8. <br /> ✓12. Alarm systems shall include both audible and visible alarms and shall be located <br /> perSection 3105(d)9. <br /> f13. Accessible parking stalls are required per Tabie No. 31-F and Secdon 3107(b). <br /> Seven ('n accessible stalls are required far the revised pazking areas. <br /> ��14. The phazmacy toilet room must be accessible. <br /> ✓1:. Please provide detai?s and engineering calculations for the exterior retaining <br /> walls in the loading dock area. <br /> ✓16. Please provide sections and details of the exterior produce cooler to illustrate <br /> type type of conswc6on. <br /> ✓17. The finish schedule incorrecdy indicates a 6" resilient base for the toilet rooms. <br /> Section 510(b) requires the flooring material to extend 5" up the wall. <br /> ✓18. A grease trap is required. <br /> �9. Please provide mechanical equipment information to verify compliance with the <br /> W.S.E.C. <br /> ;/20. Please provide lighting control information including daylight azea controls. <br /> +�21. Please provide information on the interior lighting control time clock per Secdon <br /> 1513.6.2 W.S.E.C. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two complete new sets of drawings reflecting the <br /> corrections requested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.