My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
823 LINDEN ST 2016-05-24
>
Address Records
>
LINDEN ST
>
823
>
823 LINDEN ST 2016-05-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2016 11:05:57 AM
Creation date
5/24/2016 11:05:50 AM
Metadata
Fields
Template:
Address Document
Street Name
LINDEN ST
Street Number
823
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IP <br /> 09:39:51 a.m. 05-29-2015 3'6 <br /> All <br /> 1 _1 lLLAN <br /> Insulation Certificate/Attic Card /SLA Testing <br /> Batts and Blankets Thermal Performance(Attic Application) <br /> When Installed In accordance with the manutacturera The stated therms'resistance(R-value)is rrovided by instating in arcoTance with the mamr'aclusr's instructions,the respired number of bags <br /> recommendations,Kraut baits and blankets wi provide per 1.030 sq.h.of net area.al not less than the labeled minimum thickness. -allure to instal both the required number of bangs and at least the <br /> the full R-value. m nlmun thickness wi I result in lower inst.iation R-varve. <br /> R-Value' Minimum Thickness 'R-Vents' :° Begs/1,ODDeq.-ft. Maximuln Coverage Minimum Weight Minimum Thickness <br /> To Obtain An insu aeon Installed Insulation should riot To Oolaln an Insulation The number of Contends of(his bag should riot Thu weight'EF cl insla led Installed insulators should <br /> resistance(R•Value)of: he less than' resistance(R-Value)of: bags/1,000 SF of net cover more than: Irsulat on should not ho not be less than: <br /> area ehmdd not be less less than: <br /> R-38HD 1025" 13-60 31.7 31.5 SF .952 LBS 19.75" <br /> R-3BHD 12.00" R-50 25.8 38.7 SF .774 LBS 16.75" <br /> R-30HD 8.25" R-44 22.1 45.3 SF .663 LBS 14.75" <br /> R-30 10.00" R-38 19.0 52.7 SF .569 LBS 13.00" <br /> R-20 9.00" R-30 14.4 69.7 SF .431 LBS 10.25" <br /> R-22 6.50" R-26 12.4 80.9 SF .371 LBS 9.00" <br /> R-21 HD 5.50" R-22 10.4 95.8 SF .313 LBS 7.75" <br /> R-19 6.25"" R-19 8.9 111.8 SF .268 LBS 6.75" <br /> R-15HD 3.50" R-13 6.1 164.3 SF .183 LBS 4.75" <br /> R-13 3.50" R-11 5.1 197.6 SF .152 LBS 4.00" <br /> R-11 3.50" Bag Weight-Henna! Minimum 29 lbs.This product comtorns In toe performance requirements of ASTM C 764,Type I,and cancelled <br /> R-8 2.50" Federal Specification HH-1.10308,Type I,Class B. H-Values are determned in accordance with C 687 arid C 510. "R"means resistance to <br /> "R•18 in a 5.5'cavity.Conforms;o ASTM C665 and heat Pow.The higher the R•value,the greater tin resist on power. To get the marked El-value,it Is eseential that:he insulation be Installed <br /> Federal Spacilicalion HH•-521 F. property. ft you do It yourself,get Inslructlons and follow them caret;By. <br /> "20U9 t3EC Residential Energy Compliance Certificate_Building Air Leakage Framing Adjustment <br /> To compensate for framing members,the number of bags per 1.000 sq.ft.of arca to be <br /> Building Air Leakage target: SLA Less than 0.00030 insulated should be as shown below. <br /> R-Value I- Joist Bags/MSF 16"O.C. Bags/MSF 24"0.C. . <br /> Tested Leakage SLA:= f Dimentions Framing Framing <br /> 2x4 31.2 31.3 <br /> R-60 2x6 30.8 31.1 <br /> 2x8 30.5 30.8 <br /> 2x4 25.3 25.4 <br /> R-50 2x6 25.0 252 <br /> R-Value . I-:.Standard 2x8 24.6 25.0 <br /> Attic Area R. 49 49 2x4 21.5 21.7 <br /> Sloped Cei.ings R- WA WA R-44 2x6 21.2 21.5 <br /> Walls R. 21/13 21/13 2x8 20.9 212 <br /> Floors(over an unheated craw.space) R. WA WA 2x4 18.4 18.6 <br /> R-3e 2x6 18.1 18.4 <br /> Completed as of: 5/26/2015 2x8 17.8 182 <br /> 2x4 13.0 14.0 <br /> Site Address: Grandview Renovations R-30 2x6 13.5 13.8 <br /> 813 Linden St 2x8 13.3 13.6 <br /> Everetl,WA 2x4 11.9 12.0 <br /> Home Builder R-26 2x6 11.6 11.8 <br /> Signature: 2x8 11.3 11.6 <br /> 2x4 9.9 10.1 <br /> Home Builder Allied Construction R-22 2x6 9.7 9.9 <br /> Address: 2x8 9.7 9.7 <br /> 2x4 8.5 8.8 <br /> 8-19 2x6 8.2 8.4 <br /> 2x8 7.9 8.2 <br /> Insulation . 2x4 5.6 5.8 <br /> Contractor: Magellan Insulation 13-13 2x6 5.4 5.6 <br /> 22706 58th Place South 2x8 5,1 5.4 <br /> Kent.WA 98032 2x4 4.6 4.7 <br /> R-11 2x6 4.3 4.5 + j \ <br /> _ 2x8 4.1 4.3 V\,...___y' <br />
The URL can be used to link to this page
Your browser does not support the video tag.