My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2802 HOYT AVE EVERETT ELKS 2018-01-02 MF Import
>
Address Records
>
HOYT AVE
>
2802
>
EVERETT ELKS
>
2802 HOYT AVE EVERETT ELKS 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/16/2022 12:16:55 PM
Creation date
1/27/2020 10:52:59 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2802
Tenant Name
EVERETT ELKS
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
336
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BXUV.D925 - Fire Resistance Ratings - ANSVUL 263 <br />SEE ITEM <br />I <br />'> g SEE ITEM 4 <br />Page 2 of 9 <br />s crIoh a-8 <br />Supports — W8x28,W 12x16 or alternate (per Section IV.6 in the front of the Fire Resistance Directory) steel beam or min <br />8K1 steel joists when joist substitution applied. <br />1. Normal Weight or Lightweight Concrete — Normal weight concrete carbonate or siliceous aggregate, 3500 psi <br />_ <br />compressive strength, vibrated. Lightweight concrete, expanded shale, <br />or slate aggregate by rotary <br />-kiln method, or <br />expanded clay aggregate by rotary -kiln or sintered-grate method, 3000 psi compressive strength, <br />vibrated, 4 to 7 percent <br />entrained air. <br />Restrained concrete <br />concrete Unit <br />concrete <br />_ <br />Assembly Rating Hr (Type) <br />Weight pcf <br />Thkns In. <br />I Normal Weight <br />147-153 <br />3-1/2 <br />1-1/2 Normal Weight <br />147-153 <br />4 <br />2 Normal Weight <br />147-153 <br />4 <br />3 Normal Weight <br />14'-153 <br />5-1/4 <br />3/4 or 1 Lightweight <br />107-113 <br />2-1/2 <br />(See Item 6) <br />I Lightweight <br />107-120 <br />2-5/8 <br />1-1/2 Lightweight <br />107-113 <br />3 <br />2 Lightweight <br />107-113 <br />3-1/4 <br />2 Lightweight <br />107-116 <br />3-1/4- <br />2 Lightweight <br />114-120 <br />3-1/2 -e <br />3 Lightweight <br />107-113 <br />1 4-3/16 <br />3 Lightweight <br />114-120 <br />1 4-7/16 <br />-For use with 2 or 3 in. steel floor and form units only. <br />2. Welded Wire Fabric — 6 x 6, 10 x 10 SWG. <br />3. Steel Floor and Form Units' — Composite 1-1/2, 1-5/8, 2 or 3 in. deep gals units or 4-1/2 in. deep noncomposite <br />galv units. Fluted units may be uncoated or phosphatized/painted. Min gauges are 22 MSG for fluted and 20/20 MSG for <br />cellular units. The following combinations of units may be used: <br />(1) All 18, 24, 26 28 or 36 In. wide cellular. <br />http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=... 11 /14/2007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.