. • � <br /> PUBLIC WORKS PERMIT COMMENTS <br /> 4. Connect side sewer per City Standard#601. <br /> 5. Connect side sewer per City Standard#'s 601, 602, 604. <br /> 6. Connect all rooftop downspouts to the side sewer. <br /> , ,. ) Connect rooftop downspouts to the drainage system provided for this lot. <br /> L� <br /> 8. Rooftop runoff must be discharged to a roof downspout infiltration system per City of Everett Storm <br /> Manual 3-2.6.2. The approximate size trench is 3.5'wide, 2'deep and 25' long. See attachment for <br /> more details. <br /> / 9.1 The contractor must meet wilh the Public Works Inspector to discuss potential drainage routing p�ior to <br /> �� beginninc� the project. <br /> 10. Install erosion control measures as determir�ed by the Public Works inspeclor, such as silt fence, straw <br /> bales, swales, or erosion blankets. <br /> 11. Inslail erosion conlrol measures per City o(Everetl Star.dards for small parcels <br /> � <br /> 12. � Remove erosion control measures upon completion of the project prior lo final approval of the permil. <br /> 13. � All excavated malerial from foundation, sidewalk and driveways shall be hauled to an approved, <br /> permitled site. No wasting of material is allowed on lhis building lot. <br /> 14� No dirt, mud, rocks or debris to be lrecked onto roadway. <br /> 15. No building malerials to be stacked on sidewaiks and sidewalks to be kept clean and open for <br /> pedesirian travel. <br /> 1G. Adjust waler meter box 1"above sidewalk grade. <br /> 17. Remove and replace curb, gutter and sidewaik as per Ciry of Everett Standard Plan#'s 305A 8 306 on <br /> this proposal's(rontage as directed by the Public Works Inspector(i.e. ail unused driveways and any <br /> broken or damaged area must be replaced). <br /> 18. Instell a Type I concrete driveway per City of Ever�tt Standard #307. <br /> 19. Pave driveway(rom the front properly line oul to the slreet paving. <br /> 20. Contacl the Water Districl for connecting provisions for this building's water and <br /> sewer sen•ices. <br /> 21. A calch basin as per City 5tandard Pian/1402 witli a gas trap uer Standard Plan#iA10 is required for the <br /> parking area. <br /> 22. If a sewer pump system is to be installed, the pressure Iine must discharge inlo a private manhole, then <br /> gravity flow across the pu6lic ric�hl-of-way. <br /> 23. A sprinkler system is required for tliis building in compliance wilh the requirements of NFDA Standards <br /> 13D. <br /> PWComments <br />