My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2722 COLBY AVE 2019 Plans 2022-12-07
>
Address Records
>
COLBY AVE
>
2722
>
Plans
>
2722 COLBY AVE 2019 Plans 2022-12-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/7/2022 2:16:23 PM
Creation date
1/29/2020 3:32:13 PM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2722
Permit
B1902-006
Year
2019
Notes
TI FOR FUTURE TENANT AND COMMON CORRIDOR CHANGES
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� <br /> � <br /> U <br /> � SCR Architects <br /> � � . <br /> �' 1916 Pike Place Suite 12-367 <br /> � Seattle, WA 98101 <br /> � <br /> 206.458. <br /> � <br /> 1. BUILDING ASSEMBLIES SYMBOL: <br /> � , <br /> � � <br /> 0 <br /> " BUILDING ASSEMBLIES ARE KEYED TO THIS SCHEDULE <br /> ASSEMBLIES ARE IDENTIFIED BY NUMBER: <br /> - 01-09 WOOD FRAMED INTERIOR PARTITIONS <br /> 5/8"TYPE'X'GWB EACH SIDE 11-19 LIGHT GAUGE METAL FRAMED PARTITIONS 1A ss�s <br /> TYPIG�L BLOGKING 21-29 CONCRETE AND MASONRY WALL R RCHI E CT <br /> 31-39 EXTERIOR WALLS <br /> �r�' - 41-49 FLOOWCEILING ASSEMBLIES <br /> �..� _ " Scott Alan onnor � <br /> ; _ <br /> � METAL FRAMING AT 16"O.C. 51-59 ROOFICEILING ASSEMBLIES STATE OF WASHINGTON <br /> j.:: - ALPHA CHARACTERS INDICATE MODIFICATIONS <br /> �.�. 3-518"STUDS-TYPICAL <br /> NOTE: PROVIDE MINIMUM 2x6 BLOGKING AT ALL NEGE55,4RY ;r:. TOP O� OBJ�GT 2. BRACE PARTITIONS AT MINIMUM 8'-0"O.C.,ALTERNATING SIDES <br /> LOG�TIONS, WF�LL, GEILING OR FLOOR TO AGGEPT ATTAGHMENT � � <br /> �OR WALL AGGE550RIE5, GABINETS, HANDRAILS OR ANY �;.: - MINERAL WOOL BATT 3. STC RATED ASSEMBLIES ARE BASED ON IBC, UL,OR US GYPSUM ASSOCIATION(GA)TEST DATA AND ARE TO BE <br /> : � INSULATION-TYPICAL <br /> OTHER MOUNTED OB.IEGT — TYPI GAL GONTINUOUS 2x WO D ' - CONSTRUCTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE TESTING AGENCIES. REFER TO SPECIFIC TEST <br /> BLOGKING :�.�I li � REPORTS INDICATED FOR REQUIRED COMPONENTS AND ASSEMBLY.CONTRACTOR SHALL PROVIDE(2)COPIES OF <br /> G E N E R A L G O N T R f k G T O R S H A L L GOO RD I N AT E fi�L L B LOG K 1 NG °.�j 1l2"PLYWOOD PER PLAN E A C H R E F E R E N C E D M A N U A L T O T H E J O B S I T E T O C O O R D I N A T E S O U N D R A T E D A S S E M B L I E S. G A 6 0 0 M A N U A L I S <br /> BETWEEN DIFFERENT TRADES ; �, �� ACCEPTED BY 2015 IBC TABLE 721,1(2)NOTE M FOR NON-PROPRIETARY ASSEMBUES. <br /> — 5EE SPEGIFIGATIONS .��.; ' <br /> I�; ��.�: ;, .� 4.SUBSTITUTE MOLD AND WATER RESISTANT GYPSUM BOARD AT TOILET,SHOWER AND SIMILAR . <br /> P�R PLAN D h��;l� �OVIDE BLOGKIKG AT �; :', "WET"USES. . <br /> �.�. T O P O� O B J E G T F O R A L L: <br /> I �� GA�81P1�T5 <br /> i.; � T A G K B O A R D S 5. PROVIDE TILE BACKER BOARD AT TILE FINISHES. <br /> i MARKERBOA�RD5 <br /> E�: � ; OR SIMILAR 6. PROVIDE BLOCKING AT THE FOLLOWING LOCATIONS:CASEWORK, SHELVING,AND PANELING;ACCESSORIES AND �, <br /> I,... ; ; R A T I N G: M O D I F I E R: E Q U I P M E N T; D O O R H A R D W A R E;T O I L E T A C C E S S O R I E S; A N D O T H E R o <br /> � � FIRE 1 -HOUR-INDICATED ON PLAN WHERE INDICATED ON PLAN-NON-RATED ELSEWHERE LOCATIONS WHERE REQUIRED PER MANUFACTURER'S RECOMMENDATIONS OR INDUSTRY STANDARDS. � <br /> � ; <br /> � L/GA GA FILE N0.WP 1072 � <br /> 7. FIREBLOCK IN ACCORDANCE WITH 2O15 IBC SECTION 718 AT THE FOLLOWING CONCEALED DRAFT LOCATIONS: IN <br /> STC 45-49-NRCC 816,2-3-81 CONCEALED WALL SPACES AT 1p'O.C. EACH WAY AND AT CEILING/FLOOR LEVELS. <br /> TEST FM WP-45,6-19-68 A,AT INTERCONNECTIONS OF CONCEALEQ SOFFITS, DROPPED CEfLINGS AND COVES <br /> B. IN OPENINGS AROUND VENTS, PIPES,DUCTS AT CEILING/FLOOR LEVELS. � <br /> �1 1NTERIOR PARTITION C.AT OPENINGS BETWEEN ATTIC SPACES AND MANUFACTURED CHIMNEY CHASES. <br /> I 3OI�5 �OR �LOGKING 2 3M�To L STUD BLOGKING - TOP 8.THESE DETAILS REPRESENT MINIMUM ARCHITECTURAL REQUIREMENTS, IN SOME CASES THE STRUCTURAL <br /> DRAWINGS WILL DETERMINE THE ACTUAL DIMENSIONS AND CONNECTION METHODS,AND IN THOSE CASES WILL <br /> GOVERN.COORDINATE BETWEEN SCOPE SHOWN BY THE STRUCTURAL DRAWINGS AND INDICATED MINIMUM <br /> ARCHITECTIJRAL ASSEMBLIES. <br /> ., <br /> a <br /> ...� <br /> r; � <br /> �::�:; �- <br /> �:: � <br /> �.... <br /> �.... <br /> ,. : WGONTINUOUS 2x WOOD �:� � G�NTERLIi� OF � <br /> BLOGKING ..i'; � <br /> � ATTAGHMENT � <br /> ..i W <br /> ' W <br /> ;:; Z . <br /> '����� � <br /> M�TAL STUD , NOl"E: � <br /> PER PLaN �•�'�� PROVIDE BLOGKING ,4T <br /> ���'' GENTERLINE POR ALL: O W <br /> '.' HANDR,41L5 <br /> �•. GRAB BARS � <br /> W " <br /> i..; OR 51MILAR <br /> � <br /> W W <br /> ..,, � <br /> Ca � : <br /> O <br /> — a <br /> � <br /> � o� <br /> � �, �, <br /> �� Nt�TA�L STUD BLOGK I NG - G�NT�RL I N� � <br /> � 6 3„_�,_o�, <br /> N� O � <br /> W <br /> �F= <br /> O� � <br /> �a � _ <br /> w� <br /> a� O <br /> �N � <br /> a� � <br /> WO <br /> �O <br /> �� . <br /> � W �: <br /> U� <br /> � �.. oc a <br /> �. <br /> �Q �.� <br /> �W N <br /> �� NOTGH WOOD A5 REQUIRED � � N <br /> �� <br /> �_ ;.:i TO �IT IN METAL STUD <br /> ai-- •..� - NP��i/� � W � <br /> 0 7 � �' <br /> ° ::' W I�- N <br /> � :� <br /> �3 ....I <br /> �r <br /> �w = � <br /> �a :: 2x6 WOOD BLOGKING (MINIMUM) . <br /> �W ;.:; PARTITION <br /> �.��. <br /> �� ,..: SCHEDULE & <br /> _� f�::� BLOCKING DETAILS <br /> o� �.. <br /> �° METAL 5TUD <br /> �� PER PLAN <br /> � �AgTENERS SCALE NTS <br /> Za <br /> N z '' i <br /> �� •� <br /> w� •j <br /> o� '�i <br /> �o . .i <br /> x <br /> 3 <br /> �o DATE: 12 / 1 / 2018 <br /> WW <br /> �� <br /> am <br /> �o <br /> w <br /> �o <br /> �Z <br /> U <br /> �`� M�T�rL STUD BLOGK I NG - TYP I GA�L <br /> �� (Q 3��_��_��� <br /> . <br />
The URL can be used to link to this page
Your browser does not support the video tag.