My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2532 ROCKEFELLER AVE 2020-01-30
>
Address Records
>
ROCKEFELLER AVE
>
2532
>
2532 ROCKEFELLER AVE 2020-01-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 11:09:25 AM
Creation date
1/30/2020 11:09:11 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2532
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
inwl <br /> EVERETT WAC 296-46B-900. ELECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAG section botow'I to determine rt pee review is rogluired or not required. .t hen select the box noxi to ra)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required,select the box next to(b) and(c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> * If item (a)-(ii, iii,or v) is selected, the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3) Electrical plan review. <br /> n (a) Electrical plan review is not required for: <br /> ❑ (i) Low voltage systems; <br /> (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project,provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv)Stand-alone utility fed services that do not exceed 250 volts,400 amperes where the project's distribution system <br /> LI does not include <br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517,2; or <br /> (C)A required fire pump system. <br /> 11 (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700,12(F); <br /> (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (0)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell, or wind electric system(s)with a total <br /> I-•' rating of 9600 watts or less. <br /> _ (vii) For installations in(a)(ii), (iii),and (v)of this subsection to be considered, the following must be available <br /> "(-.1 to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s) supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental,and chiropractic clinic"of which is a clinic or <br /> LTJ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii), <br /> n (b)Electrical plan review is required for all other new or altered electrical projects in educational, institutional,or health care <br /> I occupancies defined in this chapter. <br /> n (c)If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun <br /> Table 900-1 Table 900-2 <br /> Health or Personal Care Facilities Educational and Institutional Facilities,Places of Assembly,or Other Facilities <br /> Health or Personal Care Facility Plan Review _. <br /> Type Required Educational.Institutional,or {Plan Review <br /> -757 Ce.1 ,_, Other Facility Types Required <br /> e <br /> oLx <br /> r ,, <br /> tet:I�:nE racr.ca eg«, <br /> Notes to Tables 500-1 and 900-.'., <br /> e'ectr :':,'12r-t;5,-y5 --•. <br /> ,_'t i :ill( •i ;,If'�e:i t?bC <br /> eV'.0 ,9Ct ,'tt,Ci•:Ind C't'Crt <br /> ;e t c--at e,tfat <br /> C <br /> • <br /> PERMIT#„_,„ Page 2-Plan Review <br />