My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2020-01-30
>
Address Records
>
RUCKER AVE
>
3020
>
SNO CO HEALTH DISTRICT
>
3020 RUCKER AVE SNO CO HEALTH DISTRICT 2020-01-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 11:43:38 AM
Creation date
1/30/2020 11:42:51 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3020
Tenant Name
SNO CO HEALTH DISTRICT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2015 Washington State Energy Code Compliance Forms for Commercial,R2 and R3 over 3 stories and all R1-Page 6 of 7 <br /> Mechanical Permit Plans Checklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all RI Revised January 2017 <br /> Project Title: Snohomish Health-IRS 3020 Rucker Date 6/13/2019 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions. <br /> Applicable Location in Building Department <br /> Code Section Code Provision Information Required-Must be in permit documents <br /> (yes,no,na) Documents Notes <br /> 0402.4.1.4 Increased prescriptive <br /> C403.6 maximum vertical Indicate that all occupied,conditioned spaces are served by a DOAS per C403.6 <br /> fenestration area with DOAS <br /> Additional Efficiency Package Option,Dedicated Outside Air Systems(DOAS) <br /> C406.6 Building provided with To comply with additional efficiency package option,indicate that 90%or more of all occupied, <br /> DOAS conditioned spaces are served by a DOAS per C403.6 <br /> Multiple Zone Air Systems <br /> Air systems serving multiple Identify supply air systems serving multiple zones and the zones they serve on plans;indicate <br /> C403.4.4 whether system is VAV and method of primary air control;or provide supporting <br /> zones documentation for applied exception to VAV <br /> Provide equipment schedules on plans or MECH-EQ form that list all VAV air terminals and <br /> types <br /> VAV systems serving For each air terminal include:maximum airflow rates for primary supply air during zone peak <br /> C403.4.4 multiple zones heating and zone peak cooling;maximum airflow during reheating,recooling or mixing; <br /> minimum airflow rate to maintain required ventilation,and the basis for these values;if IMC or <br /> ASHRAE 62.1 multiple zone equation is basis for minimum flow rates,provide calculation on <br /> plans <br /> C403.4.4.1 Single duct VAV terminal Indicate single duct terminal units are configured to reduce primary supply air before reheating <br /> units or recooling <br /> C403.4.4.2 Dual duct systems-terminal For systems with separate warm air and cool air ducts,indicate terminal units are configured to <br /> units reduce the flow from one duct to minimum before mixing with air from the other duct <br /> Indicate locations of duct static pressure sensors on plans;include at least one sensor per <br /> major duct branch;verify controller setpoint pressure at each sensor is 5 1.2 inch w.g. <br /> 0403.4.1.1 VAV system static <br /> pressure sensors- For systems with zone level DDC,indicate controls are configured to monitor zone damper <br /> C403.4.1.2 sensors and DDC set points positions and reset static pressure setpoint based on the zone requiring most pressure; <br /> include control logic that automatically detects and generates an alarm if any zone excessively <br /> drives reset logic,and allows building operators to exclude zones from reset logic <br /> Multiple-zone VAV system For systems with zone level DDC controls,indicate controls are configured to automatically <br /> C403.4.4.3 ventilation optimization reduce outdoor airflow in response to changes in system ventilation efficiency;or exception <br /> controls taken <br /> C403.4.4.4 VAV system supply air reset Indicate controls automatically reset supply air temperature in response to building loads or <br /> outdoor air temperature;or exception taken <br /> Multiple Zone HVAC Systems,High Efficiency VAV-Required for systems utilizing C403.6 DOAS Exception 2,must comply with all 16 provisions <br /> C403.7, Indicate system is configured for 100%air economizer operation and complies with all related <br /> Item 1 Air economizer economizer requirements per C403.3(without economizer exceptions) <br /> C403.7, Direct digital controls(DDC) Provide DDC controls for all components of system;identify all DDC system input!output <br /> Item 2 control points;indicate capability for trending and graphical display <br /> For systems with minimum OSA>2,500 cfm,indicate outdoor airflow monitoring station that <br /> C403.7, Outdoor airflow measures OSA intake under all load conditions;indicate control sequence that increases or <br /> Item 3 measurement and reduction reduces system OSA cfm based on VAV terminal feedback of ventilation efficiency(per <br /> C403.4.4.3 without exceptions)or DCV(per C403.2.6.2) <br /> C403.7, For systems with minimum OSA>2,500 cfm,indicate supply airflow monitoring station <br /> Item 4 Supply airflow measurement capable of measuring supply air delivered to VAV terminals under all load conditions <br /> C403.7, Zone isolation and Verify maximum area served by a single HEVAV system is 5 50,000 sf,or one entire floor, <br /> Item 5 maximum area served whichever is greater;in addition if a system serves>25,000 sf,that includes areas that are <br /> expected to be occupied non-simultaneously,indicate zone isolation controls per C403.2.4.4 <br /> C403.7, Interior/exterior zone Verify that VAV terminals serving interior cooling driven loads are sized per design supply air <br /> Item 6 design supply air temperature that is 5°F higher than VAV terminals serving exterior zones <br /> temperature <br /> C403.7, Maximum air terminal inlet Identify air terminals with minimum primary airflow setpoints>50%of maximum setpoint in <br /> Item 7 velocity equipment schedule or MECH-EQ form;indicate air terminal inlet velocity does not exceed 900 <br /> fpm <br /> C403.7, Indicate DDC system sequences of operation are designed and configured per ASHRAE GPC <br /> Item 8 Sequence of operation 36 <br /> C403.7, Maximum allowable system Verify fan system bhp is 5 90%of the bhp limit per Option 2 equation in Table C403.2.11.1(1), <br /> Item 9 brake horsepower provide MECH-FANSYS form for each system <br /> Indicate all series and parallel terminal fans have electronically commutated motors;indicate <br /> C403.7, Fan-powered terminal unit DDC control system is configured to vary air terminal fan speed as a function of the load; <br /> Item 10 motor and control indicate fan speed during periods of low heating,low cooling,or ventilation only is 5 66%of <br /> peak design air flow or provide supporting documentation for applied exception <br />
The URL can be used to link to this page
Your browser does not support the video tag.