My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3311 WAVE DR 2020-01-30
>
Address Records
>
WAVE DR
>
3311
>
3311 WAVE DR 2020-01-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2020 3:31:59 PM
Creation date
1/30/2020 3:31:14 PM
Metadata
Fields
Template:
Address Document
Street Name
WAVE DR
Street Number
3311
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WAC 29646a,90VELECTRICAL PLAN REVIEW <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required.Then select the box next to (a)to <br /> tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-46B-900. If plan review is <br /> required, select the box next to (b) and (c)to acknowledge that plan review is required and the electrical plans have been provided <br /> with this permit application. <br /> * If item(a)-(ii, iii,or v) is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3) Electrical plan review. <br /> 0 (a) Electrical plan review is not required for: <br /> ❑ (i) Low voltage systems; <br /> +--❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution system <br /> o does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2; or <br /> (C)A required fire pump system. <br /> ❑ (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> • (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC 517.2; <br /> and <br /> (D)Service or feeder load calculations are increased by 5% or less. <br /> (vi) Electric power production source(s)such as solar photovoltaic,fuel cell, or wind electric system(s)with a total <br /> ❑ rating of 9600 watts or less. <br /> (vii) For installations in (a)(ii), (iii),and (v)of this subsection to be considered,the following must be available <br /> ❑ to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent protection <br /> for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> O physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br /> occupancies defined in this chapter. <br /> ® (c) If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Tabre'90t1-1 Table.9Qb-$ <br /> Health:or Personal Care Facilitieslxl, or other Facilitaes <br /> Edcic tional and Jnstrfutiona(Facrittres.Places ofAesem. y, <br /> Health or Personal Care Facility Plan:Review <br /> Type Required Educat oral.lnstrtutron.,.at of 1=Jan Review <br /> Hospital Yes Other Facility Tyres. • .Required <br /> Niar-igg home yariitor long,-teri'gi ':Yea ucational Yes: <br /> c re;?zc ln'tr}utalal Yes'; <br /> Boarding home Yes <br /> Fs Sste i Eng fdc ity Yes <br /> Private alcoholism hospital Yes totes to:Tables;30o 2 slid=9Ci0 ;. <br /> asa.ate O Ycnattic ho pitat Yes -city.author;sad to do electrical rnsp coon_ <br /> €stern ty home Yes may require plan'euu! va on fecsrty typea:not <br /> •�nbu?a.ory surge e ra i iti Yes eevi tsed b3.the department. <br /> Renal hemodiaiy is clinic Yes <br /> Resident al tre tea Blit facia y Yes //��,, 002-- <br /> J <br /> Enhanced service facility Yes- ��1,' -- <br /> c' <br /> ttlt�?'e rdniar- <br /> treEi hrliratiore Yes PERMIT# V !/ Page 2-PjI n Revi• <br /> eVb <br /> ceri[E 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.