Laserfiche WebLink
4. <br /> 1 2 3 4 5 <br /> D <br /> c SHEET NCJTES � � ' �� <br /> PANEL SUMMARY:02109�zois (E) PANEL 'DP-PORT� PRO7ECT:Everett Portables 2018 1�E E D E R S C H E D U L E � <br /> CLASSIFICATION:NORMAL VOLTAGE:240/120V 1fr3,3-WIRE maNUFacTURER:sQUARE-� 1. SEE ELECTRICAL SITE PLAN FOR ADDITIONAL INFORMATION. � • <br /> FED FROM: MAfNS:800A MAW CIRCUIT BREAKER ENCLOSURE:NEMA 3RTYPE:I-LINE COPPER CONDUCTORS � � � , <br /> MOUNTING SURFACE NEUTRAL 100°/a RATED TAG QUANTITY RACEWAY CONDUCTORS 2. EXISTING PORTABLE PANELBOARDS ARE RATED TO 22,OOOAIC. <br /> LOAD CALCULATIONS OF SETS SIZE PHASE NEUTRAL GND(NOTE 2) " <br /> 1QON 1 1-1/2" #1 #1 #8(#6) • " • ' " ' " <br /> , . .. � •. � <br /> LOAD DESCRIPTION CONNECTED LOAD DEMAND FACTOR CALCULATED LOAD FLAG NOTES. <br /> MISCELLANEOUS CONTINUQUS: - X 125% - - NOTES: <br /> EQUIPMENT&MISCELtANEOUS: 146724 x 100% = 146724 1. COPPER FEEDERS ARE BASED ON COPPER CONDUCTORS � SPLICE AERIAL CONDUCTORS TO NEW SERVICE ENTRANCE <br /> WITH THWN/THHN INSULATION. CONDUCTOR DERATING � � <br /> CONDUCTORS AT PORTABLE WEATHERHEAD. <br /> LIGHTING: 720o x 125% = 900o IS BASED ON THWN/THHN CONDUCTORS WITH 90 <br /> �• <br /> LARGEST MOTOR: - X 125% _ - DEGREES C RATING. <br /> � EQUIPMENT SHALL BE SERVICE ENTRANCE RATE�. H I� R G I S <br /> MOTORS: - X 100% _ - 3 � GROUND PER NEC AND WAC STANDARDS. mechanicai 1201 third avenue,suite 600 <br /> 2 GROUND CONDUCTOR (BONDING JUMPER) SIZE SHALL BE electrical <br /> o _ telecommunications seattle,washington 98101 <br /> RECEPTACLE: 10000 X 100/o _ 10000 INCREA5ED FOR FEEDERS FROM THE SOURCE OF A 4 ` CONNECT TO EXISTING SPARE CIRCUIT BREAKER AS INDICATED. security . <br /> energy t 206.448,3376 w hargis.biz <br /> RECEPTACLES OVER lOkYA: 22904 X 50% = 11452 SEPERATELY DERIVED SYSTEM TO THE FIRST DISCONNECTING <br /> MEANS PER NEC 250.30(A). SIZE AS INDICATED IN <br /> PARENTHESES. <br /> - . � . - <br /> (E) PRIMARY DISTRIBUTION BY UTILITY <br /> (SNOHOMISH COUNTY PUD) � � <br /> , <br /> �� <br /> C C ° - <br /> (E) POLE-MOUNTED ' <br /> UTILITY XFMR �-o— — —I — <br /> LOAD SUMMARY � � ' . <br /> 15,000 � �I ��/4'° <br /> TOTAL TOTAL CONNECTED LOAD(YA) TOTAL CALCULATED LOAD(YA) ��_ _ J <br /> CONNECTED LOAD AMPS 186,828 VA 177,176 VA • <br /> PHASE A:91,912 VA 766 A (E� SEC�N�AFZY <br /> TOTAL CONNECTED AMPS TOTAL CALCULATED AMPS SERVICE DROP ■ � � � � <br /> PHASE B:94,916 VA 791 A 778 A 738 A CONDUCTORS <br /> BY �T���-� Silver Lake ES 2018 �� <br /> NOTES: HARGIS ENGINEERS,INC. <br /> 1. 12�1 THIRD AVENUE,SUITE 600 , <br /> 2. SEATTLE,WA 98101 SER���� Po�NT P o rta b l es � <br /> 3. <br /> 4. PH:{206}448-3376 C O p <br /> 5. FAX.(2Q6)448-4450 r R � <br /> $°°N Eve rett P u b I i c <br /> PANEL SCHEDULE:03I20l2018 �E� PANEL 'P15� PROJECT:Everett Partables 2018 METER M ���OO)n <br /> 7 <br /> CLASSIFICATION:NORMAL VOLTAGE:240/120V 1�J,3-WIRE SECTION:1 OF 1 <br /> FED FROM:(E)PANEL'DP-PORT' MAINS: 100A MAIN CIRCUIT BREAKER AT <br /> MOUNT{NG:FIELD VERIFY NEUTRAL:100%RATED HOON �• <br /> CKT BREAKER LOAD LOAD BREAKER cKT 13 396 12815 Botheil Everett Hwy -e <br /> NOT ITEM DESCRIPTION NO. AMP POLE (VA} fd (VA} AMP POLE NO. ITEM DESCRIPTION NOT EVP.rP ll WA �J VZ O V <br /> LIGHTING 1 20 1 552 A 7052 90 2 2 HVAC - - - - '— — <br /> RECEPTS 3 2� 1 126D B 7052 - - 4 <br /> RECEPTS 5 20 1 1080 A 500 20 1 6 DF 1 . <br /> RECEPTS 7 20 1 900 B 100 20 1 8 NAC 1 - <br /> SPACE 9 - 1 /� - - 10 Pac� � � aooai2P � PANEL 'DP-PORT', NEMA-3R, B U I L D I N G P E RM I T <br /> SPACE 11 - 1 B - - 12 SPACE 22,��� kf�IC, 800A (240/120V, 1�, 31N� <br /> SPACE 13 - 1 A - - 14 SPa�E 03/20/2018 <br /> B PACE 15 - 1 B - - 16 SPACE g . <br /> SPACE 17 - 1 A - - 18 SPACE - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> SPACE 19 - 1 B - - 20 SPACE � ThiS draWing IS: <br /> 1. Copyright 2018 Dykeman, Inc. <br /> � ► 2. The Architecf's Instrument of Professional Service. �; <br /> I �sooA aus � 3. For use on this project only. Obtain Architect's <br /> f I written permission for any other use or reproduction. <br /> � <br /> � N � � � � ' <br /> � � 100A/2P 100Al2P � 100A/2P � 100A/2P � 100A/2P � 100Al2P � 100A/2P � �100A/2P� 100A/2P�� ( <br /> .. <br /> G SPARE — � 2018'00� <br /> LOAD CALCUI.ATIONS #2/0 AWG EXISTING EXISTING EXISTING EXISTING <br /> _ 3#1 AWG + 3#1 AWG + 3#1 AWG + 3#1 AWG + 100N 100N 100N 100N � <br /> LOAD DESCRIPTION CONN.(VA) DEMAND FACTOR CALC.(VA) — #8 AWG G, #8 AWG G, #$AWG G, #8 AWG G, <br /> MISGELLANEOUS CONT�NUOUS: - 125% - LOAD SUMMARY 1-1/2°C. 1-1/2°C. 1-1l2"C. 1-1/2°C. <br /> EQUIPMENT&MfSCELLANEOUS: 14704 100°!0 14704 Q MARK DATE DESCRIPTION <br /> LIGHTING: 552 125°fo 690 TOTAL <br /> LARGEST MQTOR: - 125% - CONNECTED LOAD AMPS �• <br /> MOTORS: - 100% - <br /> RECEPTACLE: 324d 100% 3240 PHASE A: 9,184 VA 77 A ''� <br /> RECEPTACLES OVER 10kVA: - 50°/v - EXISTING <br /> PHASE B: 9,312 VA 7$A 3#1/0 AWG + EXISTING EXISTING EXISTING 3#1/0 AWG AL. + 3#1/0 AWG AL. + 3#1/0 AWG AL. + <br /> #6 AWG G 3#1/0 AWG + 3#1/0 AWG + 3#1/0 AWG + #6 AWG G AL. #6 AWG G AL. #6 AWG G AL. <br /> QUADPLEX #6 AWG G #6 AWG G #6 AWG G QUADPLEX QUADPLEX QUADPLEX � <br /> TOTAL CALCULATED LOAD: 18,634 VA QUADPLEX QUADPLEX QUADPLEX ' <br /> TOTAL CALCUI.ATED AMPS: 78 A <br /> TQTALS: 18,496 18,634 Q - � • . <br /> NOT�s HARGIS ENGINEERS,INC. EXISTWG EXISTING EXISTING <br /> 1. PROVIDE NEW BREAKER IN AVAIIABLE SPACE A5 INDICATED. 1201 THIRD AVENUE,SUITE 600 3#1 AWG + 3#1 AWG + 3#1 AWG + 1 pON 100N 100N 100N PRINCIPAL IN CHARGE: � <br /> 2. SEATTLE,w,4 ss101 #8 AWG G; #8 AWG G, #8 AWG G, <br /> 3. 1-1/2"C. 1-1/2"C. 1-1/2"C <br /> PROJECT MANAGER: � � �. <br /> 4. PH,(206)44a-337s PROJECT ARCHITEGT: � <br /> 5. FAX.(206}448-4450 <br /> JOB CAPTAIN: � <br /> A I � al I � al I � al I � al I � al I � al I � al I � at � . � A '. <br /> I o I I o I I o I I o I d a I I o 1 I o I �I o I <br /> I N I N I N I N I N � � I � I � . <br /> Electrical One-Line <br /> ^ (E}PANEL _ (E}PANEL _ (E)PANEL _ (E)PANEL _ (E)PANEL _ (E)PANEL _ (E)PANEL _ (E)PANEL <br /> — 'P7' - 'P8' — 'P9' — 'P10' — 'P12' — 'P13' — 'P14' — 'P15� Diagram and Panel <br /> 200A 200A 200A 200A 200A 100A 100A 100A <br /> 8,704 7,794 11,074 8,075 8,377 6,540 6,737 3 5,855 Schedules � <br /> � � : <br /> �, <br /> � � � <br /> ' <br /> � 2 3 4 5 <br /> �. <br />