Laserfiche WebLink
_" . . _ ._ _ _"_--_. ___-.'_�__I II j. . ' . . . . . . <br /> t+' <br /> 'f. <br /> 5 ' i <br /> � <br /> Q <br /> N <br /> iti <br /> O � <br /> � HARDWARE N OTES D00 R AN D FRAM E N OTES � <br /> °1 6" RADIUS <br /> � THIS DETAIi.APPLIES TO ALL i ALIGN THIS DETAIL APPLIES TO ALL <br /> � PATIENT ROOMS_LISTED BELOW-_ ROOMS OTHER THAN PATIENT <br /> 00 ALL EXAM ROOMS / / ROOMS. 1. MAIN EXIT DOOR TO HAVE SIGNAGE ABOVE THE DOOR STATING: "THIS DOOR TO 1. INTERIOR METAL DOORS AND FRAME COLORS SHALL MATCH ADJACENT WALL COLORS OR AS <br /> / "' / REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" OTHERWISE SCHEDULED OR NOTED. <br /> BLOOD DRAW / Q CUSTOM ROOM NAME / 2. EXIT DOORS ARE OPERABLE FROM THE INSIDE WITHOUTTHE USE OFA KEY, �. MAXIMUM EFFORTTO OPERATE DOORS SHALL NOT EXCEED 8-1/2" POUNDS(38N)FOR EXTERIOR DOOR <br /> / z AND FLAG SYSTEM BY / 3��Typ STANDARD ROOM SIGNAGE BY AND 5 POUNDS(22N) FOR INTERIOR DOORS.ADA/ANSI 404.2.9(WHEN ALLOWED BY THE APPROPRIATE <br /> SIGNAGE FABRICATORATALL SPECIAL KNOWLEDGE OR FORCE. <br /> � p SIGNAGE VENDOR � 3. HARDWARE TO BE ADA COMPLIANT. ENFORCEMENT AGENCY,AT REQUIRED FIRE DOORS THE MAXIMUM EFFORT MAY BE WCREASED TO `' <br /> / � / NON-PATIENT ROOMS NOT EXCEED 15 POUNDS). <br /> / / 4. PROVIDE 18 GA. BACKING AT ALL WALL STOP LOCATIONS. <br /> / � / 3. HAND-ACTIVATED HARDWARE SHALL BE CENTERED BETWEEN 34" MIN AND 48" MAX INCHES ABOVE THE ' ' <br /> � J FLOOR. LATCHING AND LOCKING DOORS THATARE HAND-ACTIVATED AND WHICH ARE IN THE PATH OF <br /> � � TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE PANIC BARS, PUSH- '� �= <br /> � \ PULL ACTIVATING BARS OR OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING <br /> � �. � _ , � . <br /> � \ � � THE ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL OPERATE AS ABOVE IN ��;, ` ��: <br /> � EGRESS DIRECTION.ADA/ANSI 309.4,404.2J. <br /> �� 3/8" MDF PAINTED P-2. \� 4. FOR HINGED DOORS,THE OPENING WIDTH SHALL BE MEASURED WITH THE DOOR POSITIONED AT AN <br /> � FILM APPLIED TEXT BY SIGNAGE \ ANGLE OF 90 DEGREES FROM ITS CLOSED POSITION.ADA/ANSI 404.2.3. DOOR OPENING CLEARANCE IS <br /> FABRICATOR, COORDINATE WITH MEASURED FROM THE FACE OF THE DOOR TO THE FACE OF THE OPPOSING STOP, <br /> 10" ARCHITECT,TYPICAL AT PATIENT 5. WHERE A PAIR OF DOORS IS UTILIZED,AT LEAST ONE OF THE DOORS SHALL PROVIDE A CLEAR, 6720 SW MACADAM AVENUE, SUITE 100 <br /> ROOMS. UNOBSTRUCTED OPENENING WIDTH OF 32"WITH THE LEAF POSITIONED ATAN ANGLE OF 90 DEGREES PORTLAND, OR 97219 �' <br /> FROM ITS CLOSED POSITION.ADA/ANSI 404.2.2,404.2.3. T 503.245.7100 <br /> 6. THE FLOOR OR LANDING SHALL BE NOT MORE THAN 1/2" LOWER THAN THE THRESHOLD OF THE • � <br /> DOORWAY. CHANGES IN LEVEL> 1/4" IN HT.AND NOT MORE THAN 1/2" MAX. IN HT. SHALL BE BEVELED 1505 5TH AVE,SUITE 300 <br /> SIGNAGE DETAIL - PATIENT ROOMS SIGNAGE DETAILS - NON PATIENT ROOMS WITHASLOPENOTSTEEPERTHAN1:2.ADA/AN51303.2, 3033. SEATfLE,WA98101 <br /> ,_ , „ „� , „ 7. DOOR SURFACES WITHIN 10" OF THE FLOOR, MEASURED VERTICALLY, SHALL BE A SMOOTH SURFACE T 206,576.1600 � <br /> 3/8' - 1 -0 3/8 1 -0 ON THE PUSH SIDE EXTENDING THE FULL WIDTH OF THE DOOR. <br /> 1014 HOWARD STREET <br /> SAN FRANGSCO, CA 94103 <br /> T 415.252.7063 � <br /> O ANKROM MOISAN ARCHITECTS, INC. <br /> <� <br /> HARDWARE G RO U PS , � <br /> DOOR SCH EDU LE - - <br /> HW GROUP 1 PRODUCT NUMBER FINISH MANUFACTURER - <br /> DOOR FRAME - <br /> 3 HINGE(HEAVY WEIGH� T4A3786 4-1/2"x 4-1/2" U526D MCKINNEY - , � <br /> 1 MORTISE LATCH (PRIVACY W/INDICATOR) ML2030 NSB M19V 626 CORBIN RUSSWIN _ SIZE <br /> �., <br /> 1 KICKPLATE K1050 8"x 34"4BE CSK U532D ROCKWOOD W <br /> 1 WALL STOP 406 US32D ROCKWOOD = <br /> 1 GASKETING S88W(HEAD&JAMBS) PEMKO DOOR FIRE p � u HEADER HARDWARE - - <br /> NO. ROOM NAME RATING 3 = � TYPE MAT'L FINISH TYPE MAT'L FINISH HEIGHT GROUP COMMENTS h�� ��'! �"`� �� � � � � � �� '�� �� <br /> HW GROUP 2 001A WAITING NR 3' -0" 7'-0" 1 3/4" FG ALUM ANODIZ 2 ALUM ANODIZ GROUP 10 DOOR, FRAME,AND HW FINISH TO MATCH EXISTING STOREFRONT <br /> 3 HINGE(HEAVY WEIGH� T4A3786 4-1/2"x 4-12" US26D MCKINNEY ED ED <br /> �. <br /> 1 CYLINDRICAL LOCK(PASSAGE) CL3510 NZD 626 CORBIN RUSSWIN 002A RECEPTION NR 2'-6" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 5 <br /> 1 AUTOMATIC DOOR BOTfOM 411ARL PEMKO 003 EXAM 1 NR 3'-0" 7'-0" 1 3/4" F SCW P-3 1 HM P-2 GROUP 3 • - <br /> 1 WALL STOP 406 U532D ROCKWOOD 004 EXAM 2 NR 3'-0" 7' -0" 1 3/4" F SCW P-3 1 HM P-2 GROUP 3 <br /> 1 GASKETING S88W(HEAD &JAMBS) PEMKO 005 EXAM 3 NR 3'-0" 7' -0" 1 3/4" F SCW P-3 1 HM P-2 GROUP 3 <br /> — � ' <br /> HW GROUP 3 006 EXAM 4 NR 3' -0" 7'-0" 1 3/4° F SCW P-3 1 HM P-2 GROUP 3 _ � � <br /> 3 HINGE(HEAVY WEIGHT) T4A3786 4-1/2"x 4-1/2" US26D MCKINNEY 007 EXAM 5 NR 3'-0" 7'-0" 1 3/4" F SCW P-3 1 HM P-2 GROUP 3 W <br /> 1 CYLINDRICAL LOCK(PASSAGE) CL3510 NZD 626 CORBIN RUSSWIN 008 COACH 1 NR 3'-0" 7'-0" 1 3/4" F SCW P-3 1 HM P-2 GROUP 3 NO KICKPLATE � <br /> 1 AUTOMATIC DOOR BOTfOM 411ARL PEMKO 009 COACH 2 NR 3'-0" 7'-0" 1 3/4" F SCW P-3 1 HM P-2 GROUP 3 NO KICKPLATE W � <br /> 1 KICKPLATE K1050 8"x 34"4BE CSK US32D ROCKWOOD 009A CLOSET NR 6'-0" 7'-0" 1 3/4" BP SCW P-5 1 HM P-5 GROUP 9 > <br /> 1 FLOOR STOP 1211 626 TRIMCO 010 WC STOR NR 3'-0" 7' -0° 1 3/4° F SCW P-5 1 HM P-5 GROUP 5 W <br /> 1 GASKETING S88W(HEAD &JAMBS) PEMKO -- - -- -- — <br /> 011 EXPANDED NR 3' -0" 7' -0" 1 3/4° F SCW P-3 1 HM P-2 GROUP 3 T �� <br /> HW GROUP 4 _ EXAM 6 _ _ .L <br /> 3 HINGE TA2714 4-1/2"X 4-1/2" US26D MCKINNEY 012 PATIENTTLT 2 NR 3'-0" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 1 � ' - <br /> 1 CYLINDRICAL LOCK(PASSAGE) CL3510 NZD 626 CORBIN RUSSWIN 013 SOILED NR 3'-0" 7'-0" 1 3/4° F SCW P-5 1 HM P-5 GROUP 5 � <br /> — <br /> 1 KICKPLATE K1050 8"x 34"4BE CSK US32D ROCKWOOD 014 CLEAN NR 3'-0" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 5 <br /> 1 WALL STOP 406 U532D ROCKWOOD 015A LAB CLEAN NR 3'-7 7' -0" 1 3/4" SL1 SCW P-5 3 HM P-5 AD SYSTEMS EXAM SLIDE DOOR. 36" CLR OPENING. HW PER W - <br /> 1/4° MANUFACTURER <br /> HW GROUP 5 015B LAB CLEAN NR 3'-7 7'-0° 1 3/4° SL1 SCW P-5 3 HM P-5 AD SYSTEMS EXAM SLIDE DOOR.36" CLR OPENING. HW PER W Q <br /> 3HINGE TA27144-1/2"X4-1/2" US26D MCKINNEY 1/4" MANUFACfURER <br /> 1 CYLINDRICAL LOCK(STOREROOM) CL3557 NZD AP 626 CORBIN RUSSWIN m <br /> 1 DOOR CLOSER(REG ARM, PULL SIDE) DC6200 689 CORBIN RUSSWIN 016A LAB DIR7Y NR 3' -7 7'-0" 1 3/4" SL1 SCW P-5 3 HM P-5 AD SYSTEMS EXAM SLIDE DOOR.36" CLR OPENING. HW PER J z O <br /> 1/4" MAN U FACTU RE R <br /> 1 KICKPLATE K1050 8"x 34"4BE CSK US32D ROCKWOOD - W � <br /> 1 WALL STOP 406 U532D ROCKWOOD 0166 LAB DIRTY NR 3' -7 7'-0" 1 3/4" SL1 SCW P-5 3 HM P-5 AD SYSTEMS EXAM SLIDE DOOR.36" CLR OPENING. HW PER = W d� W <br /> L' <br /> 1/4" MANUFACTURER � Q � <br /> HW GROUP 6 017 PATIENT TLT 1 NR 3'-0" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 1 � � > > . , <br /> 3 HINGE(HEAVY WEIGHT) T4A3786 NRP 4-1/2"x 4-1/2" US26D MCKINNEY 019A BREAK NR 3'-0" 7'-0" 1 3/4" FG ALUM ANODIZ 2 ALUM ANODIZ GROUP 11 DOOR, FRAME,AND HW FINISH TO MATCH EXISTING STOREFRONT W W <br /> 1 ACCESS CONTROL MORTISE LOCK(STAND ALONE) ML20834 NSZ AP 626 CORBIN RUSSWIN ED ED W � � <br /> 1 DOOR CLOSER(REG ARM, PULL SIDE) DC6200 689 CORBIN RUSSWIN W O . <br /> 019B BREAK NR 3'-0" 7' -0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 4 (� � � <br /> 1 WALL STOP 406 US32D ROCKWOOD W � ; _ <br /> 020 JANITOR NR 3'-0" 7' -0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 5 \ <br /> HW GROUP 7 021 CLINIC NR 3' -0" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 2 / � W V <br /> 6 HINGE TA27144-1/2"x4-1/2" US26D MCKINNEY MANAGER <br /> 1 SET AUTOMATIC FLUSH BOLTS 3815L X 3825L 626 TRIMCO 022 MEDS/DME NR 3' -0" 7'-0" 1 3/4" F � SCW P-5 1 HM P-5 GROUP 6 <br /> 1 DUSTPROOF STRIKE 3911 630 TRIMCO � 023 PROVIDER NR 3'-0" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 4 <br /> 1 CYLINDRICAL LOCK(STOREROOM) CL3557 NZD AP 626 CORBIN RUSSWIN 023A COATS NR 4'-0" 7' -0" 1 3/4" BP SCW P-5 1 HM P-5 GROUP 9 REVISION DATE REASON FOR ISSUE <br /> - L' <br /> 2 DOOR CLOSER(P ARM, PUSH SIDE W/STOP ARM) DC6210 x A4 689 CORBIN RUSSWIN 024 STAFF TOILET 3 NR 3'-0" 7'-0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 1 1 08/16/19 PERMIT SET <br /> 1 COORDINATOR 3094B4 600 TRIMCO 025 PERSONAL NR 3'-0" 7' -0" 1 3/4" F SCW P-5 1 HM P-5 GROUP 8 . <br /> 2 CLOSER MTG BRACKETS 30956/3096 AS REQUIRED 600 TRIMCO 026 IT/ELEC NR 3'-0" 7' -0" 1 3/4" F SCW P-5 1 HM P-5 GROUP S <br /> HW GROUP 8 . <br /> 3HINGE TA27144-12"x4-1/2" US26D MCKINNEY � <br /> 1 CYLINDRICAL LOCK(PASSAGE) CL3510 NZD 626 CORBIN RUSSWIN <br /> 1 WALL STOP 406 US32D ROCKWOOD - - - - <br /> 1071� <br /> � HW GROUP 9 <br /> R,��I�"���ED <br /> r 1 BYPASS DOORTRACKAND HARDWARE HBP200A F134C PEMKO ��������� <br /> - 2 BYPASS DOOR PULL 11156 630 TRIMCO <br /> o HWGROUP10 DOOR TYPES LEGEND DOOR FRAMES LEGEND �� `� . <br /> � 3 HINGE 661191 ANSI A5112 NRP 4-1/2"X 4-1/2" TBD HAGAR � .` <br /> � 1 MORTICE CYLINDER 20-001/C123 TBD scH�a�E maLL wo F ' <br /> > 1 RIM CYLINDER 20-022 TBD SCHLAGE 1 � 9 3 �����' Q� ���x������ <br /> °' 1 ELECTRIC STRIKE 6111 FSE DS 24V TBD VON DUPRIN A7.03 �P A7.03 �P A7,03 �P A7.03 �P � <br /> � . 2 OFFSET DOOR PULL 8190-0-0 TBD IVES � <br /> °' 1 POWER OPERATOR 4640 TBD LCN <br /> � 2 PUSHPLATES 8310-818T(2"X4") TBD LCN �- <br /> � 1 DOOR CLOSER(REG ARM, PULL SIDE) 7/DC6200 TBD CORBIN RUSSWIN ,'� �� i ' � � D O O R L E G E N D AN D � <br /> v SEALS 297AS TBD PEMKO �' �� i i' TYP TYP TYP TYP �� i TYP <br /> � 1 SWEEP 318AV TBD PEMKO ,'� �� i ,�� \� i <br /> °J 1 THRESHOLD 253X3AFG TBD PEMKO �' �� i ,' Z � 8 5 � � � SCH EDU LE <br /> � i <br /> > ' \� � '� A7.03 A7.03 � A7.03 A7,03 ` � A7.03 � <br /> s HW GROUP 11 �� �� � �� �� i ,� ' <br /> � 3 HINGE BB1191 ANSI A5112 NRP 4-1/2°X4-1/2° TBD HAGAR ,' `�; / �� i . , <br /> = 1 MORTICE CYLINDER 20-001/C123 TBD SCHLAGE � E i�� � j E � P E RM IT S ET <br /> °J 2 OFFSET DOOR PULL 8190-0-0 TBD IVES �� i �� � i �� <br /> � 1 DOOR CLOSER(REG ARM, PULL SIDE) 7/DC6200 TBD CORBIN RUSSWIN �� i �� �� i �� � <br /> @ SEALS 297AS TBD PEMKO �� i� �� �� IMPACT RESISTANT ; `� � <br /> � 1 SWEEP 318AV TBD PEMKO �� i� �� `� SAFEIY GLAZING � `� <br /> � � i � � i � <br /> °1 1 THRESHOLD 253X3AFG TBD PEMKO `� � �� `� � `� <br /> o �� i � � i � � <br /> � ` � � ` � � DATE REVISION <br /> °�° F SL1 FG BP 08/16/19 � <br /> � (FLUSH) (SLIDER) (FULL GLASS) (BYPASS) � • 2 3 <br /> � 10 �P PROJECT NUMBER �' <br /> �° A7.03 181950 <br /> � <br /> a 4 , <br /> v SCALE <br /> � As indicated <br /> � � <br />