My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
4933 EVERGREEN WAY 2019 VERA WHOLE HEALTH Plans 2022-11-28
>
Address Records
>
EVERGREEN WAY
>
4933
>
VERA WHOLE HEALTH
>
Plans
>
4933 EVERGREEN WAY 2019 VERA WHOLE HEALTH Plans 2022-11-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 3:45:04 PM
Creation date
1/31/2020 3:36:49 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
4933
Tenant Name
VERA WHOLE HEALTH
Permit
B1908-036
Year
2019
Notes
TI CONVERTING RETAIL SPACE TO VERA CLINIC
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�.. , <br /> � <br /> � <br /> � <br /> N <br /> � <br /> � UNATTACHED AT WALL T <br /> rn TO STRUCTURE OR TWO FIXTURE HANGING WIRES AT <br /> N - SEISMIC JOINT � OPPOSITE CORNERS SECURED TO <br /> n u u u u u u FOR CEILING HEIGHTS, SEE STRUCTURE <br /> � TYPICAL GRID REFLECTED CEILING PLAN <br /> 8 STRUCTURE 6 9A � COMPRESSION POSTAT <br /> 8"MAX <br /> 5 TWO(2) MAIN RUNNER 12 FEET OC EACH WAY <br /> 4 9B - �- METAL FRAMING UP TO LIGHT CLIPS AT <br /> p STRUCTURE ABOVE OPPOSITE CORNERS <br /> w <br /> 3 13 9A � 11 � <br /> 2 - SUSPENDED ACT SYSTEM <br /> a � , <br /> 0 0 o Q i <br /> � o <br /> 2". 12 � 4'-0". � 4'-0". � v <br /> J <br /> � <br /> 6'-0"MAX LATERAL BRACE AT 12'-0"OC MAX � w <br /> GRID SYSTEM REQUIREMENTS 2,500 SQ FT Q °C � <br /> o O � � <br /> - GRID SYSTEM RATING: HEAVY DUTY. M� _ � <br /> Q G :�_ � HANGER WIRE AT 45 <br /> - DESIGN REQUIREMENTS: CEILINGS MUST BE DESIGNED PER 2012 IBC FOR SEISMIC Q � Z REVEAL DEGREES FOUR WAYS 6720 SW MACADAM AVENUE, SUITE 100 <br /> CATEGORIES D, E, &F,ASCE 7-02,AND CISCA RECOMMENDATIONS FOR SEISMIC � � � - WOOD CEILING SYSTEM - P O R T L A N D, O R 9 7 2 1 9 <br /> ZONES 3&4. � <br /> a�' UPTURNED END PANEL SAFETY WIRE ATTACHED TO T 503.245.7100 <br /> INSTALLATION: II :��������;��. '� <br /> �'"' CEILING GRID FIXTURE <br /> 1O MAIN RUNNERS:4 FEET OC, SUPPORTED WITH NO. 12 GA WIRES AT 4 FEET OC(OR ' HOUSING WRAPPED AROUND MAIN RUNNER 1505 5TH AVE,SUITE 300 <br /> NO. 10 GA WIRES AT 5 FEET OC). HANGER ATTACHMENT TO BE DESIGNED TO ; WOOD CEILING SYSTEM ANGLE FIXTURE HANGING WIRE MIN. SEATTLE,WA 98101 <br /> SUPPORT NOT LESS THAN 200 POUNDS. FOUR TIMES. SECURE AT T 206.576.1600 <br /> SUSPENDED LINEAR WOOD DIAGONAL CORNERS NOT <br /> 2O CROSS RUNNERS: RUNNERS SUPPORTED BY MAIN RUNNERS AND CAPABLE OF CEILING SYSTEM CONTAINING MAIN RUNNER CROSS RUNNER 1014 HOWARD STREET <br /> CARRYING DESIGN LOAD WITH DEFLECTION EQUAL TO 1/360 OF ITS SPAN OR LESS PARTITION TYPE SAN FRANCISCO, CA 94103 <br /> LIGHT CLIPS TYPICAL BRACING CONNECTION <br /> TO UNDERSIDE WOOD CEILING SYSTEM CLIP NOTE: T 415.252.7063 <br /> O3 HANGER WIRE SYSTEM TO BEGIN WITHIN 8 INCHES OF PERIMETER WALL. ., ATTACHED - OF GRID DOES REQUIREMENTS ARE FOR LIGHT FIXTURES WEIGHING 56 LBS OR LE55. LIGHT FIXTURES �O ANKROM MOISAN ARCHITECTS, INC. <br /> NOT EFFECT 2,500 WOOD CEILING LINEAR PLANK WEIGHING MORE THAN 56 LBS TO BE INDEPENDENTLY SUPPORTED FROM <br /> 4O GRID LATERAL FORCE BRACING: BEGIN WITHIN 6 FEET OF PERIMETER AND WITHIN 2 SF MAX AREA <br /> INCHES OF CROSS RUNNER INTERSECTION. (A.) FOUR(4)-NO. 12 GA WIRES STRUCTURE <br /> SECURED TO MAIN RUNNER AND SPLAYED 90 DEGREES FROM EACH OTHER IN PLAN �� �� � <br /> ��„ . <br /> ATAN ANGLE NOT EXCEEDING 45 DEGREES FROM CEILING PLANE. (B.) BRACE AT 12 ' <br /> ; <br /> TYP SUSPENDED CLG SYSTEM PLAN WOOD CEILING TO ACT CLG RECESSED LIGHT FIXTURE BRACE 9 <br /> FEET OC EACH WAY. . ' � <br /> O5 COMPRESSION STRUTAT EACH LATERAL GRID BRACING LOCATION. STRUTTO BE <br /> ADEQUATE TO RESIST VERTICAL FORCE COMPONENT INDUCED BY BRACING WIRES, 1/4"= 1'-0" 3"= 1'-0" 1 1/2" = 1'-0" <br /> SPACED 12 FEET ON CENTER IN BOTH DIRECTIONS. STRUT TO BE COMPATIBLE WITH <br /> SUSPENSION SYSTEM. <br /> OSYSTEM HANGERS MORE THAN 1:6 OUT OF PLUMB, PROVIDE COUNTER SLOPE <br /> HANGERS. �;�' � � � � �� � � � � <br /> O7 WHERE HANGER WIRES ARE NOT POSSIBLE DUE TO OBSTRUCTIONS, PROVIDE <br /> TRAPEZE OR EQUIVALENT DEVICE.TRAPEZE SUSPENSION FOR SPANS EXCEEDING 48 NO. 12 GAUGE SUPPORT — COMPRESSION POSTAT <br /> INCHES TO BE MINIMUM OF BACK-TO-BACK 1-1/41NCH COLD ROLLED CHANNELS. WIRE AT45 DEGREES � 17_ FEET OC EACH WAY <br /> O8 EACH HANGER WIRE ANCHOR TO STRUCTURE CAPABLE OF CARRYING 100 POUNDS FOUR WAYS �S° <br /> MINIMUM. <br /> �`� � FOR CEILING HEIGHTS, SEE <br /> Og LIGHT FIXTURE SUPPORT: � REFLECTED CEILING PLAN � <br /> 0 � <br /> A. WITH SUSPENSION SYSTEMS, NO. 12 GA HANGERS TO BE ATTACHED TO GRID MEMBERS Q � �� ;_� W <br /> WITHIN 3 INCHES OF EACH CORNER OF EACH FIXTURE-TANDEM FIXTURES MAY USE 3/4"CLEAR AT - � <br /> COMMON WIRES. UNRESTRAINED END, ��'M � �'�'� � <br /> LIGHT FIXTURES WEIGHING LESS THAN 56 LBS RE UIRE 2 NO. 12 GA SLACK WIRES EACH DIRECTION � � B I <br /> B. Q c � o � � W <br /> FROM FIXTURE HOUSING TO STRUCTURE ABOVE. � <br /> C. LIGHT FIXTURES IN EXCESS OF 56 LBS TO BE SUPPORTED DIRECTLY FROM STRUCTURE � 0 i <br /> ABOVE,WIRES MUST BE TAUT. 7/8" CLOSURE ANGLE p I o 0 0 0 0 0 � <br /> D. LIGHT FIXTURES TO BE POSITIVELY ATTACHED TO GRID SYSTEM.ATTACHMENT DEVICE FASTEN TO STUDS ---` � - i , � <br /> TO CARRY 100 PERCENT OF LIGHT FIXTURE WEIGHT ACTING IN ANY DIRECTION. m � -- ,:-, <br /> \ ° " NO. 12 GAUGE PERIMETER � J <br /> 10 INTERIOR PARTITION WALLS EXTENDING TO GRID THAT DO NOT ALIGN WITH 4-WAY ` �� HANGER WIRE � � I _ Q <br /> BRACING OF GRID MUST HAVE THEIR OWN LATERAL WALL BRACING. � �o o CROSS RUNNER �- MAIN RUNNER SUSPENDED ACOUSTICAL W <br /> MAIN RUNNER CEILING SYSTEM <br /> 11 PROVIDE SEISMICJOINTS WHERE CEILING AREA EXCEEDS 2,500 SF OR PROVIDE -�\, / � � o � i <br /> FULL HEIGHT PARTITION. ��8 /� L SEISMIC CLIP � ° o MAXIMUM RECOMMENDED LENGTHS FOR VERTICAL STRUTS �' �- <br /> e EMT CONDUIT I WALL ANGLE W Q <br /> 12 2 INCH CLOSURE ANGLE AT PERIMETER OF EACH 2,500 SF SUSPENDED CEILING PER ES REPORT Q �p � � J � M� <br /> SYSTEM, (2)SIDES TO BE ATTACHED TO ADJACENT WALLS, (2)OPPOSITE ADJACENT � °� 1/2" EMT CONDUIT UP TO 5'-10" - - - - � <br /> SIDES TO BE UNATTACHED. � � � 3/4" EMT CONDUIT UP TO 7'-8" O W � <br /> ° 1" EMT CONDUIT UP TO 9'-9" = w � W <br /> 13 WHERE SPRINKLER HEADS AND OTHER PENETRATIONS OCCUR, PROVIDE 2 INCH ° B � Q � <br /> OVERSIZED ESCUTCHEON OR ADAPTER TO ALLOW AT LEAST 1 INCH MOVEMENT IN INSTALL SUSPENDED CEILING � METAL STUD � � ? <br /> ALL HORIZONTAL DIRECTIONS, OR PROVIDE STANDARD ESCUTCHEON AND SYSTEM PER ES REPORT ESR-1308 SINGLE 1 5/8" METAL STUD (20 GAUGE) UP TO 12'-0" GYPSUM BOARD CORNER W W <br /> PENETRATIONS WITH FLEXIBLE HEAD CONNECTION. BACK TO BACK 1 5/8" METAL STUD(20 GAUGE) UP TO 15'-0" B�� W � Ll- <br /> SINGLE 2 1/2" METAL STUD (20 GAUGE) UP TO 13'-6" GYPSUM BOARD CEILING ON W O <br /> BACKTO BACK 2 1/2" METAL STUD (25 GAUGE) UP TO 15'-0" METAL STUD FRAMING W � ; � <br /> � � w � <br /> IBC CEILING NOTES PERIMETER SUPPORT FOR SUSPENDED CLG GRID LATERAL FORCE BRACE CLG GYP TO ACT DETAIL <br /> 1 1/2"= 1'-0" 3"= 1'-0" 3"= 1'-0" 3"= 1'-0" <br /> REVISION DATE REASON FOR ISSUE <br /> 1 i 08/16/19 PERMIT SET <br /> 10715 � <br /> REGI S'�'ERED <br /> AR�HITECT <br /> 0 <br /> I�V� <br /> � ; <br /> � MOLL W4 F <br /> ` S�'ATE �F WA�HZNGTQN <br /> > <br /> 0 <br /> � <br /> rn <br /> � <br /> � <br /> � STAN DARD CE I LI N G <br /> � <br /> v <br /> � D ETAI LS <br /> v <br /> > <br /> w <br /> s <br /> � <br /> � <br /> � <br /> = PERM IT SET <br /> � <br /> 0 <br /> s <br /> � <br /> � <br /> v <br /> > <br /> � <br /> � <br /> 0 <br /> � DATE REVISION <br /> � 08/16/19 1 <br /> � <br /> � <br /> � PROJECT NUMBER % " `°" i <br /> �° 181950 <br /> a <br /> � <br /> > SCALE � ���� <br /> v <br /> � As indicated �I��" ��"��''y '�"' <br /> � <br /> ��(�������,�� i;� <br />
The URL can be used to link to this page
Your browser does not support the video tag.