Laserfiche WebLink
��� <br />9H <br />,a�x <br />>ym <br />y � r�i <br />�e n <br />H x1 <br />oxo <br />'�J H n] <br />V] H <br />t�- o � <br />OH� <br />�/��o <br />y� V � <br />H � <br />9H� <br />t� z <br />Hy <br />d� <br />Q H <br />C� C7 [n <br />� e� r <br />zym <br />H O f/� <br />�m � <br />.�.. � <br />�� �1 <br />� <br />�i. i �`■ <br />C3 �q� <br />E"� � <br />,u I <br />d.:.. r 1 <br />c g"'j <br />'l1�L/�" �/O/2KS <br />September 7, 1992 <br />blr. Brian Olson <br />6503 1'svergreen Way <br />Everett, Washington 98203 <br />RE: Owner: <br />Job Address: <br />Plan Check No: <br />Dear Mr. Olson: <br />Brian Olson <br />6503 Evergreen Way <br />B-37629 <br />In response to your application for a construction permit; your plans have been exr ��^Pd and <br />you are advised that [he issuance of a permit is being withheld for the reasons listed •_ _.�w. <br />These comments address building issues only, additional revisions or additions may Ue <br />required by odier departments (such as Utilities, Planning or Fire). All references refer to the <br />1988 Uniform Building Code and/or Washington State Energy Code unless stated othenvise. <br />I. The plans submitted are incom��lete. The comments that follow are general in nature <br />and may not be complete. <br />An additional plan review response may be reyuired after receipt of completecl plans. <br />�2. All Buildings and additions to buildings over 4,000 square feet require the plans and <br />specifications to be prepared by an azchitect currently licer.sed to practice in the State <br />of Washington. Prov�de architects seal on each sheet of dnwings. <br />�3. Roof coverings are required to be C1ass C, Table No. 32-A. Details or specifications <br />complying with Section 3204 are required. <br />�4. Attic ventilation shall be provided with a net azea of 5.6 square feeL Section 3205(c) <br />�/ 5. Roofing drainage shall not flow over public property. Section 3207(e). <br />� 6. Overflow drains having the same size as roof drains and on independent drain lines <br />are requirecl. In lieu of this, overflow scuppers three times the size of roof drains can <br />be instailed in parapet walls. The overFlow drain system is required to have inlets <br />located 2 inches above the low poin[ of the roof. Section 3207(c). <br />V 7. Roof systems must be sloped a minimum of 1/4 inch in 12 inches for drainage. <br />Section 2305(�. <br />�/ 8. Roof covering application must comply with Section 3208. <br />r� 9. A weather-resis[ive Uamer must be applied to exterior walls as specified in Section <br />1707(a). <br />CITY OF EVERETT• 3200 Cedar Slreet • Everelt, WA 98201 •(206) 259-8800 • Fax (206) 259-88R2 <br />