My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
120 SE EVERETT MALL WAY BLDG 1 2018-01-02 MF Import
>
Address Records
>
SE EVERETT MALL WAY
>
120
>
BLDG 1
>
120 SE EVERETT MALL WAY BLDG 1 2018-01-02 MF Import
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2020 10:30:08 AM
Creation date
2/4/2020 10:16:20 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
120
Tenant Name
BLDG 1
Imported From Microfiche
Yes
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
117
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
N �� <br />CiTY Of rVERETT <br />BUILDING DEPARTh1ENT <br />PLAN CORRECTION SHEET <br />DATE Februarv 5, 19R6 <br />UWNER Crow-Western Co. <br />CONTRACTOR <br />DESIGNER <br />JOB SITE ADDRESS 120 SE Evt Mall Wav <br />TYPE OF CONSTRUCTION <br />USE <br />iISE ZONING <br />FIRE ZONE <br />OCCUPANCY GROUP <br />OCCUPANT LOAD <br />PLAN CNECK N0. 85/15743 <br />In response to your application for a permit, your plans and specifications <br />have been examined and you are advised that the issuance of a permit is <br />withheld for the reasons hereinafter sot forth. VOTE CAREFULLY: Answer <br />questions and make explanations bv correctin� ori inal lans, and new <br />plans must be submitted to the Buil ing Inspection Department. (This sheet <br />must be returned with original plans and specifications or they will be <br />filed as new business.) <br />Item No. <br />l. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />UNIPOR,1 BUILDING CODE 1982 EDITIO� <br />All footings exposed to the exterior must extend 18" below <br />grade. See Details 1, 2, and 4 on 5-9. Slab edge must be <br />insulated with 2' wide x R6.35. <br />Doors to patios and balconies cannot swing over the <br />landing. <br />Roof live load in this area is 25 pounds per square foot. <br />Al1 interior gypsum wallboard throughout the project must <br />be 5/8" Type "X" except on non-loadbearing walls. <br />Provide attic draft stops aSove and in line with the wall <br />separating tenant spaces and one of the corridor walls. <br />Additional firestopoing is required if condition exists as <br />shown on Details 11 and 12, Sheet A26. <br />Insulation shall be provided as follows: R-30 in attics, <br />(continuous vapor barrier required where average height <br />of ventilation soace above the insulation is less than 12"), <br />R-13 with vapor barrier in exterior walls, R-11 unfaced <br />sound batts in floor-ceilings and walls separating units. <br />Roof coverings shall be fire retardant. <br />Stairways shall be provided with handrails on each side <br />CODE SEC. <br />3304(h) <br />2516(f) <br />1980 Energy Code <br />3202(b) � <br />3306(g) <br />Page � of 2 <br />